Autonomous image-based ultrasound probe positioning via deep learni

Author(s):  
G Toporek ◽  
◽  
H Wang ◽  
M Balicki ◽  
H Xie
Keyword(s):  
POCUS Journal ◽  
2016 ◽  
Vol 1 (3) ◽  
pp. 13-14
Author(s):  
Stuart Douglas, PGY4 ◽  
Joseph Newbigging, MD ◽  
David Robertson, MD

FAST Background: Focused Assessment with Sonography for Trauma (FAST) is an integral adjunct to primary survey in trauma patients (1-4) and is incorporated into Advanced Trauma Life Support (ATLS) algorithms (4). A collection of four discrete ultrasound probe examinations (pericardial sac, hepatorenal fossa (Morison’s pouch), splenorenal fossa, and pelvis/pouch of Douglas), it has been shown to be highly sensitive for detection of as little as 100cm3 of intraabdominal fluid (4,5), with a sensitivity quoted between 60-98%, specificity of 84-98%, and negative predictive value of 97-99% (3).


Author(s):  
Tomohito Hasegawa ◽  
Norimichi Kawashima ◽  
Shinichi Takeuchi ◽  
Mutsuo Ishikawa ◽  
Minoru Kuribayashi Kurosawa

2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Mohammed Obaid ◽  
Qianwei Zhang ◽  
Scott J. Adams ◽  
Reza Fotouhi ◽  
Haron Obaid

Abstract Background Telesonography systems have been developed to overcome barriers to accessing diagnostic ultrasound for patients in rural and remote communities. However, most previous telesonography systems have been designed for performing only abdominal and obstetrical exams. In this paper, we describe the development and assessment of a musculoskeletal (MSK) telesonography system. Methods We developed a 4-degrees-of-freedom (DOF) robot to manipulate an ultrasound probe. The robot was remotely controlled by a radiologist operating a joystick at the master site. The telesonography system was used to scan participants’ forearms, and all participants were conventionally scanned for comparison. Participants and radiologists were surveyed regarding their experience. Images from both scanning methods were independently assessed by an MSK radiologist. Results All ten ultrasound exams were successfully performed using our developed MSK telesonography system, with no significant delay in movement. The duration (mean ± standard deviation) of telerobotic and conventional exams was 4.6 ± 0.9 and 1.4 ± 0.5 min, respectively (p = 0.039). An MSK radiologist rated quality of real-time ultrasound images transmitted over an internet connection as “very good” for all telesonography exams, and participants rated communication with the radiologist as “very good” or “good” for all exams. Visualisation of anatomic structures was similar between telerobotic and conventional methods, with no statistically significant differences. Conclusions The MSK telesonography system developed in this study is feasible for performing soft tissue ultrasound exams. The advancement of this system may allow MSK ultrasound exams to be performed over long distances, increasing access to ultrasound for patients in rural and remote communities.


Author(s):  
Douwe M. van Willigen ◽  
Eunchul Kang ◽  
Jovana Janjic ◽  
Emile Noothout ◽  
Zu-Yao Chang ◽  
...  

2001 ◽  
Vol 101 (6) ◽  
pp. 629-635 ◽  
Author(s):  
Sagar N. DOSHI ◽  
Katerina K. NAKA ◽  
Nicola PAYNE ◽  
Christopher J.H. JONES ◽  
Moira ASHTON ◽  
...  

Flow-mediated dilatation (FMD) of the brachial artery assessed by high-resolution ultrasound is widely used to measure endothelial function. However, the technique is not standardized, with different groups using occlusion of either the wrist or the upper arm to induce increased blood flow. The validity of the test as a marker of endothelial function rests on the assumption that the dilatation observed is endothelium-dependent and mediated by nitric oxide (NO). We sought to compare the NO component of brachial artery dilatation observed following wrist or upper arm occlusion. Dilatation was assessed before and during intra-arterial infusion of the NO synthase inhibitor NG-monomethyl-l-arginine (l-NMMA) following occlusion of (i) the wrist (distal to ultrasound probe) and (ii) the upper arm (proximal to ultrasound probe) for 5min in ten healthy males. Dilatation was significantly greater after upper arm occlusion (upper arm, 11.62±3.17%; wrist, 7.25±2.49%; P = 0.003). During l-NMMA infusion, dilatation after wrist occlusion was abolished (from 7.25±2.49% to 0.16±2.24%; P < 0.001), whereas dilatation after upper arm occlusion was only partially attenuated (from 11.62±3.17% to 7.51±2.34%; P = 0.006). The peak flow stimulus was similar after wrist and upper arm occlusion. We conclude that dilatation following upper arm occlusion is greater than that observed after wrist occlusion, despite a similar peak flow stimulus. l-NMMA infusion revealed that FMD following wrist occlusion is mediated exclusively by NO, while dilatation following upper arm occlusion comprises a substantial component not mediated by NO, most probably related to tissue ischaemia around the brachial artery. FMD following wrist occlusion may be a more valid marker of endothelial function than dilatation following upper arm occlusion.


1999 ◽  
Vol 76 (1-3) ◽  
pp. 197-202 ◽  
Author(s):  
K.A. Roome ◽  
P.A. Payne ◽  
R.J. Dewhurst

2021 ◽  
Vol 11 (1) ◽  
pp. 452
Author(s):  
Long-Jun Ren ◽  
Connie Lok-Kan Cheng ◽  
Christina Zong-Hao Ma ◽  
Yong-Ping Zheng

Muscle hardness and its relationship with different muscle lengths/positions are important for understanding its underlying physiological status, and yet remained unclear. This study aimed to detect the local muscle hardness at different muscle lengths and identify the influence of muscle position on muscle hardness in healthy adults. A total of 26 healthy adults participated in this study. Shear wave elastography (SWE) was used to measure the muscle hardness of the Rectus Femoris (RF), Tibialis Anterior (TA) and Gastrocnemius Medialis (GM). Each muscle was tested at both resting (RST) and mid-range lengthened (MRL) positions. A novel ultrasound probe placing method was introduced, applied, and evaluated in this study. Moderate to excellent intra-/inter-rater reliability (Intraclass Correlation Coefficient, ICC ≥ 0.70) was found for muscle hardness measurements. The muscle hardness significantly increased from the RST to MRL position for all three muscles (p < 0.001). This study found that the muscle hardness increased at its mid-range lengthened position from the resting position. The mid-range lengthened muscle position of TA and GM could also be sensitive enough to reflect the age-related changes in local muscle hardness. This study also highlights the importance of placing the assessed extremities in an appropriate and consistent position when assessing muscle qualities by ultrasonics in clinical practice.


Author(s):  
Smruti Mahapatra ◽  
Tarana Parvez Kaovasia ◽  
Sufia Ainechi ◽  
Ana Ainechi ◽  
Molly Acord ◽  
...  

Abstract Standard diagnostic ultrasound imaging procedures heavily rely on a sonographer for image acquisition. Given the ultrasound probe is manually manipulated by the sonographer, there is a potential for noise artifacts like blurry acquired images caused by involuntary hand movements. Certain surgical procedures can also cause patients to exhibit involuntary “jumping” movements while on the operating table leading to further deterioration in ultrasound image quality. In this study, we attempt to mitigate these problems by fabricating a 3D-printed ultrasound probe holder. Due to the lightweight nature of the device, it can attach to surgical retractors without influencing the functionality of the retractor. Therefore, the 3D printed probe holder not only reduces relative motion between the probe and the patient, but also reduce the need for a sonographer during complex surgeries.


Author(s):  
A. Ramireddy ◽  
E. D. Light ◽  
S. W. Smith
Keyword(s):  