scholarly journals ULTIMATE STRENGTH AND DEFORMATION CAPACITY OF A STEEL AND CONCRETE COMPOSITE PILE-GROUP FOUNDATION BASED ON THE STATIC HORIZONTAL LOADING TEST

Author(s):  
Akio YABUUCHI ◽  
Katsuichiro HIJIKATA ◽  
Tatsuya SUGIYAMA ◽  
Masanobu ITOU ◽  
Kazushige FUJIWARA ◽  
...  
Author(s):  
Takashi KURATA ◽  
Hisatoshi KASHIWA ◽  
Yasuhiro HAYASHI ◽  
Shuji TAMURA ◽  
Keiichiro SUITA

Author(s):  
Satoshi MIYAKI ◽  
Chiaki MATSUI ◽  
Tatsuo HATATO ◽  
Terutake IMAMURA ◽  
Shigeru YOSHINO ◽  
...  

2010 ◽  
Vol 163-167 ◽  
pp. 1510-1514 ◽  
Author(s):  
Rui Pang ◽  
Shu Ting Liang ◽  
Xiao Jun Zhu ◽  
Yao Meng

Detailed formation of precast floor slab connectors has significant effect on their shear capacity, but there is no such specific provision on it at present. The effects of detailed formations on the shear strength, stiffness and deformation capacity of hairpin connectors(HPC) were studied, through numerical simulation analysis under in-plane shear force. The imbedded depth (d), slug length (h), steel plate thickness (t) and its stickout(s) were taken as parameters. The analysis results show that: ⅰ) the increase of imbedded depth can improve the bearing capacity and stiffness of HPC, but decrease the deformation capacity; ⅱ) with the increase of slug length, the HPC strength, stiffness and deformation capacity raised a lot; ⅲ) the steel plates’ thickness has small effect on the stiffness, but has strong impact on the strength and deformation capacity of HPC. ⅳ) the stickout can affect the initial stiffness and yield strength of HPC slightly, but has a considerable impact on its ultimate strength and deformation capacity. On the basis of analysis, recommendations on formation details of HPC are proposed for design and construction.


2018 ◽  
Vol 2018 ◽  
pp. 1-17 ◽  
Author(s):  
Tianzhong Ma ◽  
Yanpeng Zhu ◽  
Xiaohui Yang ◽  
Yongqiang Ling

It is very necessary to research the bearing characteristics of composite pile group foundations with long and short piles under lateral load in loess areas, because these foundations are used widely. But few people researched this problem in loess areas up to now worldwide. In this paper, firstly, an indoor test model of a composite pile foundation with long and short piles is designed and then employed to explore the vertical load bearing characteristics and load transfer mechanisms of a single pile, a four-pile group, and a nine-pile group under different lateral loads. Secondly, ANSYS software is employed to analyze the load-bearing characteristics of the test model, and for comparison with the experimental results. The results demonstrate the following. (1) The lateral force versus pile head displacement curves of the pile foundation exhibit an obvious steep drop in section, which is a typical feature of piercing damage. A horizontal displacement limit of the pile foundation is 10 mm and 6mm for the ones sensitive to horizontal displacement. (2) The axial force along a pile and frictional resistance do not coincide, due to significant variations and discontinuities in the collapsibility of loess; a pile body exhibits multiple neutral points. Therefore, composite pile groups including both long and short piles could potentially maximize the bearing capacity and reduce pile settlement. (3) The distribution of stress and strain along the pile length is mainly concentrated from the pile head to a depth of about 1/3 of the pile length. If the lateral load is too large, short piles undergo rotation about their longitudinal axis and long piles undergo flexural deformation. Therefore, the lateral bearing capacity mainly relies on the strength of the soil at the interface with the pile or the horizontal displacement of the pile head.


2019 ◽  
Vol 15 (1) ◽  
pp. 65-83
Author(s):  
Rana Faisal Tufail ◽  
Xiong Feng ◽  
Muhammad Zahid

Abstract The use of rubberized concrete (RuC) is an effective environmental approach to reduce the amount of scrap tires around the world. However, there are serious concerns regarding the compressive strength of RuC. This article investigates the use of externally bonded carbon fiber reinforced polymer (CFRP) jackets on RuC to develop a novel high strength and deformable CFRP confined RuC. In this study, 66 RuC cylinders were cast with 0, 10, 20, 30, 40 and 50% fine or coarse rubber to replace mineral aggregates. The RuC cylinders were then confined with one, two or three layers of CFRP jackets. The results indicated 208% high lateral strains in unconfined RuC as compared to the conventional concrete. CFRP jacketing was highly effective for enhancing the compressive strength and deformation capacity of RuC, where high compressive strength enhancement of 52 MPa and deformation capacity (317% axial strain) was achieved. The confined compressive strength test results were compared with the strength models to assess their validity for CFRP confined RuC. An analysis-oriented strength model was developed to predict the axial compressive strength of RuC confined by CFRP jackets. Overall, this study demonstrated the potential of using CFRP-confined RuC as a new structural material with improved strength and deformation.


2015 ◽  
Vol 25 (3) ◽  
pp. 212-220 ◽  
Author(s):  
Erik Levold ◽  
Andrea Restelli ◽  
Lorenzo Marchionni ◽  
Luigino Vitali ◽  
Caterina Molinari ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document