Oculomotor Function Testing in Acute Concussion

Author(s):  
2018 ◽  
Vol 29 (07) ◽  
pp. 587-595 ◽  
Author(s):  
Kathleen M. McNerney ◽  
Mary Lou Coad ◽  
Robert Burkard

AbstractWhen patients are given instructions before vestibular function testing, they are often asked to refrain from ingesting caffeine 24 h before testing. However, research regarding the effects of caffeine on the outcome of vestibular function testing is limited.To evaluate whether the results from rotational chair tests are influenced by caffeine.Participants were tested after consuming a caffeinated beverage (i.e., coffee containing ∼300 mg of caffeine), as well as after abstaining from caffeinated beverages. The participants underwent oculomotor testing, sinusoidal harmonic acceleration testing, optokinetic testing, visual enhancement/suppression testing, subjective visual vertical/horizontal testing, trapezoidal step testing, and unilateral utricular centrifugation testing.Thirty healthy young controls aged 18–40 yr (mean = 23.28 yr; 9 males, 21 females) participated in the study.Rotational chair tests were completed with the Neuro Kinetics rotary chair (Pittsburgh, PA). VEST 7.0 software was used to collect and analyze the participants’ eye movements (I-Portal VOG; Neuro Kinetics). IBM SPSS was used to statistically analyze the results.Statistically significant differences were found for the results from several oculomotor tests (i.e., vertical saccades [SCs], horizontal SCs, and optokinetics), whereas the remaining rotational chair tests did not reveal any statistically significant differences between sessions. If a statistically significant difference was found, the participants were then stratified based on the amount of caffeine they consumed on a daily basis. This stratification was accomplished based on the guidelines from the International Coffee Organization. When the data were analyzed based on the stratified groups, statistically significant results remained in the no/low caffeine intake group, whereas no statistically significant results remained in the moderate/high caffeine intake group. Clinically speaking, the largest effect was seen in those individuals who did not typically ingest large amounts of caffeine, whereas the results were not found to be significantly different in those individuals who were typical caffeine consumers. This strengthens the argument that it is not necessary to require that individuals refrain from consuming caffeinated beverages before oculomotor/rotary chair testing as the results from typical caffeine consumers are not significantly affected.Although statistically significant results were found for a number of the oculomotor function tests, the ingestion of caffeine had little influence on the clinical interpretation of the responses. Therefore, the results from the present study indicate that it is not necessary to require that healthy young individuals abstain from caffeine before undergoing rotary chair/oculomotor testing. Further research is necessary to determine whether there is also a limited effect of caffeine on rotary chair/oculomotor test results from older individuals, as well as individuals diagnosed with a vestibular impairment.


Sports ◽  
2021 ◽  
Vol 9 (12) ◽  
pp. 166
Author(s):  
Dearbhla Gallagher ◽  
Doug King ◽  
Patria Hume ◽  
Trevor Clark ◽  
Alan Pearce ◽  
...  

Objective: To document baseline King-Devick (K-D) oculomotor function scores for male and female participants aged between 4 and 20 years old. Methods: Utilising a cross section of schools, rugby clubs and gymnastic clubs, 1936 participants (1300 male, 636 female) completed the spiral-bound K-D test for the identification of disturbed oculomotor function. Results: This study identified that overall, the baseline scores of the K-D test became faster by 1.4 (0.3 to 4.5) s per year, when compared with the previous age group in the same number of reading card groups. When comparing normative values of the original K-D validation study with the same age groups of the current cohort, participants aged 6 to 11 years recorded a faster baseline time (range 3.5 to 8.6 s), while those in the 12 to 14 years. age group recorded slower baseline times (range −3.9 to −7.9 s). Discussion: In general, there were age group differences, but not sex differences, for K-D test times in the current cohort. Analysis of single card times, across all age groups, showed changes likely due to improved reading time. Conclusion: The results support the need for individualised annual pre-injury baseline testing of the K-D test.


2015 ◽  
Vol 53 (05) ◽  
Author(s):  
K Gyorgyev ◽  
A Rudas ◽  
I Wagner ◽  
Á Altorjay ◽  
F Izbéki

2019 ◽  
Author(s):  
Bakhtiyar Pashaev ◽  
Liliya Hisanova ◽  
Dmitriy Bochkarev ◽  
Valeriy Danilov ◽  
Andrey Alekseev ◽  
...  

Author(s):  
Mathias Poussel ◽  
Isabelle Thaon ◽  
Emmanuelle Penven ◽  
Angelica I. Tiotiu

Work-related asthma (WRA) is a very frequent condition in the occupational setting, and refers either to asthma induced (occupational asthma, OA) or worsened (work-exacerbated asthma, WEA) by exposure to allergens (or other sensitizing agents) or to irritant agents at work. Diagnosis of WRA is frequently missed and should take into account clinical features and objective evaluation of lung function. The aim of this overview on pulmonary function testing in the field of WRA is to summarize the different available tests that should be considered in order to accurately diagnose WRA. When WRA is suspected, initial assessment should be carried out with spirometry and bronchodilator responsiveness testing coupled with first-step bronchial provocation testing to assess non-specific bronchial hyper-responsiveness (NSBHR). Further investigations should then refer to specialists with specific functional respiratory tests aiming to consolidate WRA diagnosis and helping to differentiate OA from WEA. Serial peak expiratory flow (PEF) with calculation of the occupation asthma system (OASYS) score as well as serial NSBHR challenge during the working period compared to the off work period are highly informative in the management of WRA. Finally, specific inhalation challenge (SIC) is considered as the reference standard and represents the best way to confirm the specific cause of WRA. Overall, clinicians should be aware that all pulmonary function tests should be standardized in accordance with current guidelines.


Sign in / Sign up

Export Citation Format

Share Document