Cryoballoon Pulmonary Vein Isolation vs. Radiofrequency Pulmonary Vein Isolation With Additional Right Atrial Linear Ablation for Paroxysmal Atrial Fibrillation: Prospective Randomized Trial (CRAPAF Trial)

Author(s):  
Author(s):  
Filip Casselman ◽  
Ihsan Bakir ◽  
Pedro Brugada ◽  
Peter Geelen ◽  
Francis Wellens ◽  
...  

Objective To evaluate the feasibility and results of isolated endoscopic pulmonary vein isolation for paroxysmal atrial fibrillation using robotics. Methods Between November 2004 and December 2005, 13 patients (38.5% female) underwent robotic pulmonary vein isolation at our institution. Mean age was 46.8 ± 8.4 years and mean preoperative duration of atrial fibrillation was 52.7 ±31.5 months. Indication for surgery was symptomatic drug-refractory paroxysmal atrial fibrillation or recurrence after percutaneous treatment (n = 3). Mean preoperative left atrial dimension was 38.5 ± 6.9 mm. The surgical procedure was performed off-pump as an isolated right chest approach. All procedures were performed using the Flex 10 microwave ablator (Guidant, Indianapolis, IN), which was positioned from the right side through the transverse sinus and around the 4 pulmonary veins. Postoperative drug regimen included sotalol and Coumadin. Mean follow-up was 8.5 ± 3.4 months. Results The procedure was successful in 11 patients. One patient needed conversion to median sternotomy for right pulmonary artery bleeding and a second patient had severe transverse sinus adhesions requiring conversion to a bilateral video-assisted small thoracotomy approach. No other morbidity occurred. Mean procedure time in successful cases was 2.7 ± 0.8 hours (range 1.7 to 4 hours). Permanent sinus rhythm was successfully restored in 10 of 13 patients (76.9% beyond 6 months). Nonsuccessful patients had markedly reduced symptoms and frequency of events. One patient required a left and another a right atrial flutter ablation during follow-up. Conclusions Robotic pulmonary vein isolation is a feasible procedure that has the potential to become a valid option in the treatment of paroxysmal atrial fibrillation.


2020 ◽  
Vol 33 (2) ◽  
pp. 106-114
Author(s):  
Michele Brunelli ◽  
Mark Adrian Sammut

Catheter ablation of long-standing persistent atrial fibrillation is not yet clearly defined with respect to endpoints, and different ablative strategies are offered to patients. Presented here is an approach aiming at biatrial debulking in the form of extensive linear ablation, specifically targeting areas of low-voltage complex fractionated electrograms, in addition to pulmonary vein isolation. Its main advantage is that it is not dependent on operator/system variability, since the strategy of isolating the pulmonary veins, superior vena cava and left atrial posterior wall together with achievement of bidirectional block during linear ablation provides objective endpoints that can consistently be reproduced.


2009 ◽  
Vol 18 ◽  
pp. S164
Author(s):  
Taching Tan ◽  
Toon Wei Lim ◽  
Choon Hiang Koay ◽  
Valerie A. See ◽  
Rebecca McCall ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document