Risk factors for intraoperative lateral mass fracture of lateral mass screw fixation in the subaxial cervical spine

2014 ◽  
Vol 20 (1) ◽  
pp. 11-17 ◽  
Author(s):  
Shinichi Inoue ◽  
Tokuhide Moriyama ◽  
Toshiya Tachibana ◽  
Fumiaki Okada ◽  
Keishi Maruo ◽  
...  

ObjectAlthough lateral mass screw fixation for the cervical spine is a safe technique, lateral mass fracture during screw fixation is occasionally encountered intraoperatively. This event is regarded as a minor complication; however, it poses difficulties in management that may affect fixation stability and clinical outcome. The purpose of this study is to determine the incidence and etiology of lateral mass fractures during cervical lateral mass screw fixation.MethodsA retrospective clinical review of patient records was performed in 117 consecutive patients (mean age 57 years, range 15–86 years) who underwent lateral mass screw fixation using a modified Magerl method from 1997 to 2010 at a single institution. A total of 555 lateral masses were included in this study. The outer diameters of the screws were 3.5 or 4.0 mm. In the retrospective clinical analysis, the incidence of intraoperative lateral mass fractures was reviewed. Potential risk factors for this complication were assessed using multivariate analysis.ResultsThe incidence of lateral mass fractures during cervical lateral mass screw fixation was 4.7% (26 lateral masses) among all cases. Among the disorders, the incidence was highest in patients with destructive spondyloarthropathy (DSA) (18.8%, 12 lateral masses). There was no significant difference with respect to lateral mass fracture between the use of 4.0-mm screws (5.6%) and 3.5-mm screws (3.6%). Independent risk factors identified by logistic regression were DSA (OR 7.89, p < 0.001) and screw insertion in the C-6 lateral masses (OR 2.80, p = 0.018).ConclusionsThe overall incidence of lateral mass fracture during cervical lateral mass screw fixation was 4.7%. Destructive spondyloarthropathy as an underlying cause of morbidity and screw placement in the C-6 lateral mass were identified as independent risk factors. Use of a 4.0-mm screw in patients with DSA may be a principal risk factor for this complication.

2012 ◽  
Vol 132 (7) ◽  
pp. 947-953 ◽  
Author(s):  
Shinichi Inoue ◽  
Tokuhide Moriyama ◽  
Toshiya Tachibana ◽  
Fumiaki Okada ◽  
Keishi Maruo ◽  
...  

2018 ◽  
Vol 8 (7) ◽  
pp. 751-760 ◽  
Author(s):  
Andrei Fernandes Joaquim ◽  
Marcelo Luis Mudo ◽  
Lee A. Tan ◽  
K. Daniel Riew

Study Design: A narrative literature review. Objectives: To review the surgical techniques of posterior screw fixation in the subaxial cervical spine. Methods: A broad literature review on the most common screw fixation techniques including lateral mass, pedicle, intralaminar and transfacet screws was performed on PubMed. The techniques and surgical nuances are summarized. Results: The following techniques were described in detail and presented with illustrative figures, including (1) lateral mass screw insertion: by Roy-Camille, Louis, Magerl, Anderson, An, Riew techniques and also a modified technique for C7 lateral mass fixation; (2) pedicle screw fixation technique as described by Abumi and also a freehand technique description; (3) intralaminar screw fixation; and finally, (4) transfacet screw fixation, as described by Takayasu, DalCanto, Klekamp, and Miyanji. Conclusions: Many different techniques of subaxial screw fixation were described and are available. To know the nuances of each one allows surgeons to choose the best option for each patient, improving the success of the fixation and decrease complications.


2015 ◽  
Vol 24 (12) ◽  
pp. 2781-2787 ◽  
Author(s):  
Gregor Schmeiser ◽  
C. Schilling ◽  
T. M. Grupp ◽  
L. Papavero ◽  
K. Püschel ◽  
...  

2009 ◽  
Vol 23 (1) ◽  
pp. 6-10
Author(s):  
Nobuyuki Shimokawa ◽  
Yoshihiko Fu ◽  
Yuji Tsukazaki ◽  
Toshiyuki Sugino ◽  
Hidetoshi Ikeda ◽  
...  

2020 ◽  
Author(s):  
Sreeramalingam Rathinavelu ◽  
Ariful Islam ◽  
Pankaj Shivhare ◽  
Sandip Chatterjee

2002 ◽  
Vol 9 (2) ◽  
pp. 121 ◽  
Author(s):  
Kyung-Soo Suk ◽  
Ki-Tack Kim ◽  
Sang-Hoon Lee ◽  
Kyung-Nam Ryu

Sign in / Sign up

Export Citation Format

Share Document