scholarly journals The fate of cranial neuropathy after flow diversion for carotid aneurysms

2016 ◽  
Vol 124 (4) ◽  
pp. 1107-1113 ◽  
Author(s):  
Benjamin L. Brown ◽  
Demetrius Lopes ◽  
David A. Miller ◽  
Rabih G. Tawk ◽  
Leonardo B. C. Brasiliense ◽  
...  

OBJECT The authors sought to determine whether flow diversion with the Pipeline Embolization Device (PED) can approximate microsurgical decompression in restoring function after cranial neuropathy following carotid artery aneurysms. METHODS This multiinstitutional retrospective study involved 45 patients treated with PED across the United States. All patients included presented between November 2009 and October 2013 with cranial neuropathy (cranial nerves [CNs] II, III, IV, and VI) due to intracranial aneurysm. Outcome analysis included clinical and procedural variables at the time of treatment as well as at the latest clinical and radiographic follow-up. RESULTS Twenty-six aneurysms (57.8%) were located in the cavernous segment, while 6 (13.3%) were in the clinoid segment, and 13 (28.9%) were in the ophthalmic segment of the internal carotid artery. The average aneurysm size was 18.6 mm (range 4–35 mm), and the average number of flow diverters placed per patient was 1.2. Thirty-eight patients had available information regarding duration of cranial neuropathy prior to treatment. Eleven patients (28.9%) were treated within 1 month of symptom onset, while 27 (71.1%) were treated after 1 month of symptoms. The overall rate of cranial neuropathy improvement for all patients was 66.7%. The CN deficits resolved in 19 patients (42.2%), improved in 11 (24.4%), were unchanged in 14 (31.1%), and worsened in 1 (2.2%). Overtime, the rate of cranial neuropathy improvement was 33.3% (15/45), 68.8% (22/32), and 81.0% (17/21) at less than 6, 6, and 12 months, respectively. At last follow-up, 60% of patients in the isolated CN II group had improvement, while in the CN III, IV, or VI group, 85.7% had improved. Moreover, 100% (11/11) of patients experienced improvement if they were treated within 1 month of symptom onset, whereas 44.4% (12/27) experienced improvement if they treated after 1 month of symptom onset; 70.4% (19/27) of those with partial deficits improved compared with 30% (3/10) of those with complete deficits. CONCLUSIONS Cranial neuropathy caused by cerebral aneurysm responds similarly when the aneurysm is treated with the PED compared with open surgery and coil embolization. Lower morbidity and higher occlusion rates obtained with the PED may suggest it as treatment of choice for some of these lesions. Time to treatment is an important consideration regardless of treatment modality.

2020 ◽  
Vol 33 (4) ◽  
pp. 297-305
Author(s):  
Mostafa Mahmoud ◽  
Ahmed Farag ◽  
Mostafa Farid ◽  
Ahmed Elserwi ◽  
Amr Abdelsamad ◽  
...  

Introduction The treatment of aneurysms in the internal carotid bifurcation region (ICABR), including aneurysms of the true internal carotid artery (ICA) terminus, those inclined on the proximal A1 or M1 segments or at the most distal pre-bifurcation (ICA) segment, is often challenging in microsurgical clipping and endovascular surgery. Few reports had discussed flow diversion as a therapeutic option for this group. Methods This was a retrospective study analysing flow diversion in treating ICABR aneurysms. Seven patients harbouring eight aneurysms in the ICABR were treated with flow diversion. Five aneurysms were inclined on the proximal A1 segment, and three were located at the most distal pre-bifurcation segment. Patients’ demographics, presentation, procedure technical description, angiographic and clinical follow-up were recorded. PubMed and Ovid MEDLINE were also reviewed for articles published in English, including case series or case reports, for ICABR aneurysms treated with flow diverters. Results All patients except one underwent angiographic follow-up. The Karman–Byrne occlusion scale was used to determine the occlusion rate. All six patients with documented angiographic follow-up had a class IV occlusion score. No permanent or transient neurological or non-neurological complications were encountered in this study. Conclusion Treating ICABR aneurysms using flow diversion is feasible, with a promising angiographic occlusion rate. Further studies are needed to analyse long-term clinical and angiographic results.


2017 ◽  
Vol 127 (1) ◽  
pp. 81-88 ◽  
Author(s):  
Tibor Becske ◽  
Matthew B. Potts ◽  
Maksim Shapiro ◽  
David F. Kallmes ◽  
Waleed Brinjikji ◽  
...  

OBJECTIVEThe long-term effectiveness of endovascular treatment of large and giant wide-neck aneurysms using traditional endovascular techniques has been disappointing, with high recanalization and re-treatment rates. Flow diversion with the Pipeline Embolization Device (PED) has been recently used as a stand-alone therapy for complex aneurysms, showing significant improvement in effectiveness while demonstrating a similar safety profile to stent-supported coil treatment. However, relatively little is known about its long-term safety and effectiveness. Here the authors report on the 3-year safety and effectiveness of flow diversion with the PED in a prospective cohort of patients with large and giant internal carotid artery aneurysms enrolled in the Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial.METHODSThe PUFS trial is a prospective study of 107 patients with 109 aneurysms treated with the PED. Primary effectiveness and safety end points were demonstrated based on independently monitored 180-day clinical and angiographic data. Patients were enrolled in a long-term follow-up protocol including 1-, 3-, and 5-year clinical and imaging follow-up. In this paper, the authors report the midstudy (3-year) effectiveness and safety data.RESULTSAt 3 years posttreatment, 74 subjects with 76 aneurysms underwent catheter angiography as required per protocol. Overall, complete angiographic aneurysm occlusion was observed in 71 of these 76 aneurysms (93.4% cure rate). Five aneurysms were re-treated, using either coils or additional PEDs, for failure to occlude, and 3 of these 5 were cured by the 3-year follow-up. Angiographic cure with one or two treatments of Pipeline embolization alone was therefore achieved in 92.1%. No recanalization of a previously completely occluded aneurysm was noted on the 3-year angiograms. There were 3 (2.6%) delayed device- or aneurysm-related serious adverse events, none of which led to permanent neurological sequelae. No major or minor late-onset hemorrhagic or ischemic cerebrovascular events or neurological deaths were observed in the 6-month through 3-year posttreatment period. Among 103 surviving patients, 85 underwent functional outcome assessment in which modified Rankin Scale scores of 0–1 were demonstrated in 80 subjects.CONCLUSIONSPipeline embolization is safe and effective in the treatment of complex large and giant aneurysms of the intracranial internal carotid artery. Unlike more traditional endovascular treatments, flow diversion results in progressive vascular remodeling that leads to complete aneurysm obliteration over longer-term follow-up without delayed aneurysm recanalization and/or growth.Clinical trial registration no.: NCT00777088 (clinicaltrials.gov)


2020 ◽  
Vol 33 (2) ◽  
pp. 105-111
Author(s):  
Xianli Lv ◽  
Jianjun Yu ◽  
Ting Liao ◽  
Jin Wang ◽  
Guihuai Wang

Background and objective Giant intracavernous aneurysms (GICAs) are located in extradural space; their clinical manifestation and treatment are different from other intradural aneurysms. This study reports clinical outcomes of GICAs untolerate internal carotid artery occlusion tests. Methods Between January 2012 and September 2017, 14 consecutive cases of GICAs untolerated internal carotid artery occlusion test were retrospectively reviewed. A total of nine patients were not treated and five patients were treated using a Pipeline Embolization Device. Results Of the 14 patients, 12 had compression symptoms and 2 were incidental. In nine untreated patients, during 34 months' (range, 7–64 months) follow-up, four worsened to headaches or ablepsia (more than 34 months). One patient, who presented with ophthalmoplegia and diplopia, showed spontaneous resolution of symptoms at 32-month follow-up. Symptoms in four patients remained unchanged during less than 36-month follow-up period. In five (100%, 95% confidence interval 57% to 100%) treated patients, symptoms recovered completely during 11 months' follow-up after transient worsening of mass compression. Conclusions GICAs frequently result in intractable cranial neuropathy requiring treatment. The Pipeline Embolization Device is an effective option for these complex aneurysms in selective cases.


Author(s):  
Jacob F. Baranoski ◽  
Tyler S. Cole ◽  
Colin J. Przybylowski ◽  
Rami O. Almefty ◽  
Dale Ding ◽  
...  

Abstract: This chapter discusses issues surrounding the management of giant cavernous carotid artery aneurysms. These aneurysms most commonly present with symptoms of cranial neuropathy. They present a unique treatment challenge given their location and often large size. Endovascular flow diversion has emerged as the mainstay of treatment, although parent vessel sacrifice, high-flow bypass, and surgical trapping are important alternatives. Evaluation of the nature of collateral circulation and the tolerance of the intracranial circulation to carotid artery sacrifice should also be part of the work-up. The technical details of endovascular flow diversion strategy are described, as well as the management of known post-procedural complications.


2017 ◽  
Vol 42 (6) ◽  
pp. E7 ◽  
Author(s):  
Craig Kilburg ◽  
Philipp Taussky ◽  
M. Yashar S. Kalani ◽  
Min S. Park

The use of flow-diverting stents for intracranial aneurysms has become more prevalent, and flow diverters are now routinely used beyond their initial scope of approval at the proximal internal carotid artery. Although flow diversion for the treatment of cerebral aneurysms is becoming more commonplace, there have been no reports of its use to treat flow-related cerebral aneurysms associated with arteriovenous malformations (AVMs). The authors report the cases of 2 patients whose AVM-associated aneurysms were managed with flow diversion. A 40-year-old woman presented with a history of headaches that led to the identification of an unruptured Spetzler-Martin Grade V, right parietooccipital AVM associated with 3 aneurysms of the ipsilateral internal carotid artery. Initial attempts at balloon-assisted coil embolization of the aneurysms were unsuccessful. The patient underwent placement of a flow-diverting stent across the diseased vessel; a 6-month follow-up angiogram demonstrated complete occlusion of the aneurysms. In the second case, a 57-year-old man presented with new-onset seizures, and an unruptured Spetzler-Martin Grade V, right frontal AVM associated with an irregular, wide-necked anterior communicating artery aneurysm was identified. The patient underwent placement of a flow-diverting stent, and complete occlusion of the aneurysm was observed on a 7-month follow-up angiogram. These 2 cases illustrate the potential for use of flow diversion as a treatment strategy for feeding artery aneurysms associated with AVMs. Because of the need for dual antiplatelet medications after flow diversion in this patient population, however, this strategy should be used judiciously.


2021 ◽  
Author(s):  
Daniel D Cavalcanti ◽  
Peter Kim Nelson ◽  
Eytan Raz ◽  
Maksim Shapiro ◽  
Erez Nossek ◽  
...  

Abstract Initially developed for large and giant wide-necked aneurysms of the internal carotid artery, flow diverter devices are now used in almost every location safely and with effectiveness.1-5 This video demonstrates a unique case of a giant aneurysm of the right petrous internal carotid artery in a 20-yr-old patient. This is an extremely rare location, and most of patients are asymptomatic.3-6 Signs of compression of the seventh and eight cranial nerves can be present and even Horner syndrome and lower cranial nerves neuropathies. Nevertheless, rupture can lead to epistaxis and otorrhagia, and ultimately to hemorrhagic shock. The patient in the current report was otherwise healthy but presented with lightheadedness and dizziness for 10 d. The patient consented to the procedure. There was no history of major trauma or head and neck infection. A transradial endovascular flow diversion embolization of a giant aneurysm of the petrous internal carotid artery is herein demonstrated in a stepwise manner. A triaxial system was used to deploy 3 overlapping devices. Concepts of J-wire technique, multiple coverage,1 and the so-called weld technique are emphasized. The role of adjunctive coiling and main reasons for failure are also discussed.7,8 Brief cases of flow diversion embolization of aneurysms of different morphologies at different locations are used to highlight the importance of assessing vessel wall apposition and follow-up imaging.


2021 ◽  
Vol 108 (Supplement_4) ◽  
Author(s):  
R Liechti ◽  
R Babst ◽  
U Hug ◽  
B -C Link ◽  
B van de Wall ◽  
...  

Abstract Objective Minimal invasive temporary spanning plate (SP) fixation of the wrist has been described as an alternative treatment method in complex distal radius fractures (DRFs). The purpose of this study is to conduct an outcome analysis of all consecutive DRFs treated by SP fixation representing the so far largest published patient cohort outside the United States. Methods Indication for SP fixation included DRFs with severe metaphyseal comminution, radiocarpal luxation fractures with concomitant ligamentous injuries and very distal intra-articular fractures lacking the possibility of adequate plate anchoring. All consecutive patients undergoing SP fixation of DRFs were prospectively included in a single level I trauma centre between 01/01/2018 and 31/12/2020. Post-operative assessments included radiological, functional and patient-rated outcomes at a minimum of 12 months follow-up. Results In the mentioned timeframe, a total of 508 DRFs were treated operatively of which 28 underwent SP fixation. Average age was 58.1 years (range 22-95 years). The fracture type ranged from AO/OTA type B1.1 to C3.3 and included 8 fracture dislocations. SP removal was performed on average 3.7 months after the initial operation (range 1.4-6.5 months). The mean follow-up time was 14.5 months (range 12-24 months). Radiological evidence of fracture healing appeared on average 9.9 weeks (range 5-28 weeks) after the initial operation. One patient experienced oligosymptomatic non-union. Complications included 2 patients with tendon rupture and one patient with extensor tendon adhesions needing tenolysis at the time of plate removal leaving an overall complication rate of 12%. There was no implant failure and no infection. Mean satisfaction score was 8 (range 0-10) and mean visual analogue scale for resting pain was 0.9 (range 0-9). The mean PRWE score was 17.9 (range 0-59.5) and the mean DASH score was 16.6 (range 0-60.8). Grip strength averaged 23kg (range 4-74kg) amounting to 68% of the opposite side. Mean radial inclination, volar tilt and ulnar variance at 1 year were all within the acceptable limit predictive of symptomatic malunion. Conclusion The radiological, functional and patient-rated outcomes in this study are remarkably good considering the complexity of the included fractures. Therefore, this method represents a valuable alternative for the treatment of complex DRFs in selected patients.


2022 ◽  
pp. 174749302110686
Author(s):  
Andrea Morotti ◽  
Gregoire Boulouis ◽  
Andreas Charidimou ◽  
Loris Poli ◽  
Paolo Costa ◽  
...  

Background: Hematoma expansion (HE) is common and associated with poor outcome in intracerebral hemorrhage (ICH) with unclear symptom onset (USO). Aims: We tested the association between non-contrast computed tomography (NCCT) markers and HE in this population. Methods: Retrospective analysis of patients with primary spontaneous ICH admitted at five centers in the United States and Italy. Baseline NCCT was analyzed for presence of the following markers: intrahematoma hypodensities, heterogeneous density, blend sign, and irregular shape. Variables associated with HE (hematoma growth > 6 mL and/or > 33% from baseline to follow-up imaging) were explored with multivariable logistic regression. Results: Of 2074 patients screened, we included 646 subjects (median age = 75, 53.9% males), of whom 178 (27.6%) had HE. Hypodensities (odds ratio (OR) = 2.67, 95% confidence interval (CI) = 1.79–3.98), heterogeneous density (OR = 2.16, 95% CI = 1.46–3.21), blend sign (OR = 2.28, 95% CI = 1.38–3.75) and irregular shape (OR = 1.82, 95% CI = 1.21–2.75) were independently associated with a higher risk of HE, after adjustment for confounders (ICH volume, anticoagulation, and time from last seen well (LSW) to NCCT). Hypodensities had the highest sensitivity for HE (0.69), whereas blend sign was the most specific marker (0.90). All NCCT markers were more frequent in early presenters (time from LSW to NCCT ⩽ 6 h, n = 189, 29.3%), and more sensitive in this population as well (hypodensities had 0.77 sensitivity). Conclusion: NCCT markers are associated with HE in ICH with USO. These findings require prospective replication and suggest that NCCT features may help the stratification of HE in future studies on USO patients.


2018 ◽  
Vol 4 (3) ◽  
pp. 141-147 ◽  
Author(s):  
Li-Mei Lin ◽  
Matthew T Bender ◽  
Geoffrey P Colby ◽  
Bowen Jiang ◽  
Jessica K Campos ◽  
...  

IntroductionInternal carotid artery termination (ICAT) and proximal A1 aneurysms can be challenging for open surgical clipping or endovascular coiling. Treatment with flow diversion covering the middle cerebral artery (MCA), an end vessel supplying a terminal circulation, has not been reported.MethodsA prospective, Institutional Review Board-approved database was analysed for patients with pipeline embolisation device (PED) placement from the anterior cerebral artery (ACA) to the ICA during cerebral aneurysm treatment.ResultsNine cases were identified, including five proximal A1, three posterior communicating artery and one ICAT aneurysm locations. Average aneurysm size was 8.3 mm (range 3–17), with 67% saccular and 78% right-sided. Primary indication for treatment was significant dome irregularity (44%), recurrence or enlargement (33%), underlying collagen vascular disorder (11%) and traumatic pseudoaneurysm (11%). Preservation of the ipsilateral ACA (with PED placed in A1) was performed when the anterior communicating artery (67%) or contralateral A1 (33%) were absent on angiography. Adjunctive coiling was done in four cases (44%). There was one major stroke leading to mortality (11%) and one minor stroke (11%). Clinical follow-up was 27 months on average. Follow-up digital subtraction angiography (average interval 15 months) showed complete aneurysm obliteration (88%) or dome occlusion with entry remnant (12%). The jailed MCA showed minimal or mild delay (primarily anterograde flow) in 75% of cases and significant delay (reliance primarily on ACA and external carotid artery collaterals) in 25%.ConclusionsCovering the MCA with a flow diverting stent should be reserved for select rare cases. Strict attention to blood pressure augmentation during the periprocedural period is necessary to minimise potential ischaemic compromise.


2020 ◽  
pp. neurintsurg-2020-016051
Author(s):  
Federico Cagnazzo ◽  
Raed Ahmed ◽  
Pierre-Henri Lefevre ◽  
Imad Derraz ◽  
Cyril Dargazanli ◽  
...  

BackgroundClinical and hemodynamic consequences of flow diverters extending from the M1 to the internal carotid artery (ICA), covering the A1 segment, have rarely been investigated. We aimed to provide angiographic and clinical data about flow modifications on the covered A1.MethodsConsecutive patients receiving M1-ICA flow diverters for unruptured aneurysms were collected from our prospective database (2014–2020).Results42 A1 arteries covered with a single device were studied. All patients had an angiographic detected contralateral flow from the anterior communicating artery (AcomA). Immediately after flow diversion, 20 (47.6%) covered A1 showed slow flow. During a mean angiographic follow-up of 14 months, 13 (31%) and 22 (52.3%) A1 arteries were occluded and narrowed, respectively. Flow changes were asymptomatic in all cases. Vascular risk factors, sex, oversized compared with not oversized stents, immediate A1 slow flow, age, diameter of the A1, length of follow-up, and platelet inhibition rate were tested as prognosticators of A1 occlusion. Length of the angiographic follow-up was the only predictor of A1 occlusion (p=0.005, OR=3, CI=1.4 to 6.7). There were two device related ischemic events with a 2.3% rate of morbidity (one basal ganglia infarct after coverage of the M1 perforators and one transient acute instent thrombosis).ConclusionsCovering the A1 segment during M1-ICA flow diversion seems relatively safe, if the contralateral flow is assured by the AcomA. Approximately 31% and 52% of the covered A1 showed asymptomatic occlusions and narrowing, respectively. The likelihood of flow modification was proportional to the length of follow-up. Morbidity associated with flow diversion in the ICA terminus region was 2.3%.


Sign in / Sign up

Export Citation Format

Share Document