scholarly journals Clipping as re-treatment strategy after treatment of a cerebral aneurysm with the Woven EndoBridge embolization device: case report

2019 ◽  
Vol 130 (3) ◽  
pp. 891-894 ◽  
Author(s):  
Gregor Durner ◽  
Yigit Özpeynirci ◽  
Bernd Schmitz ◽  
Christian Rainer Wirtz ◽  
Ralph König ◽  
...  

Recently, treatment of cerebral aneurysms with the Woven EndoBridge (WEB) device has become an established endovascular strategy. However, over time, neurosurgeons and neuroradiologists will be confronted with the challenge of how to treat aneurysm recanalization. The authors report the case of a 49-year-old woman who underwent re-treatment with clipping after the recanalization of a 4 × 3–mm anterior communicating artery aneurysm that had previously been treated using a 4 × 3 WEB device. In contrast to the authors’ prior experiences with clipping of previously coiled aneurysms, the WEB device was found to have a responsive softness during clip placement, and the aneurysm was more maneuverable. Moreover, evaluation with indocyanine green angiography was easy to perform because of the transparent mesh of the WEB device. No profound scarring or WEB protrusion was noted during surgery, making the procedure easier and less dangerous with regard to additional complications. The authors suggest that re-treatment via clipping should be considered in select cases of aneurysm recurrence after treatment with an intraaneurysmal flow diverter.

Neurosurgery ◽  
2020 ◽  
Vol 87 (1) ◽  
pp. E16-E22 ◽  
Author(s):  
Fadi Al Saiegh ◽  
David Hasan ◽  
Nikolaos Mouchtouris ◽  
Mario Zanaty ◽  
Ahmad Sweid ◽  
...  

Abstract BACKGROUND Coil embolization of ruptured bifurcation aneurysms is challenging and often necessitates adjunctive stenting, which requires antiplatelet therapy in the setting of subarachnoid hemorrhage (SAH). The Woven EndoBridge (WEB; Terumo) device is an alternative self-expanding 3D mesh that does not require antiplatelet agents. However, its use has been mostly reserved for unruptured aneurysms. OBJECTIVE To assess the safety and feasibility of ruptured aneurysm treatment with the WEB. METHODS Retrospective analysis of 9 SAH patients with 11 aneurysms that were treated with the WEB device at 2 institutions after FDA approval. RESULTS Hunt and Hess grades were III and IV in 4 (44%) each and V in 1 (11%). All patients were treated within 24 h of hospitalization, and a single WEB was used in all but one aneurysm. Aneurysms treated were 3 basilar tip, 2 anterior communicating artery, 2 posterior inferior cerebellarartery, 1 middle cerebral artery, 1 carotid-ophthalmic artery, 1 posterior communicating artery, and 1 vertebrobasilar junction. Mean aneurysm height and width were 6.2 ± 2.2 mm (range: 3-10) and 5.6 ± 3.0 mm (range: 3.3-14), respectively. Mean dome-to-neck ratio was 1.7 ± 0.8 (range: 1.0-3.8). There was one intraoperative rupture that occurred because of device dislodgement and was managed with embolization. There were no treatment-related mortalities and no re-rupture after securement of the aneurysms with the WEB. CONCLUSION Our preliminary experience indicates that the WEB device can be used safely for ruptured aneurysms of various sizes in the anterior and posterior circulation. Larger series with long-term follow-up are necessary to confirm our findings.


2021 ◽  
Author(s):  
Daniel M Heiferman ◽  
Jeremy C Peterson ◽  
Kendrick D Johnson ◽  
Vincent N Nguyen ◽  
David Dornbos ◽  
...  

Abstract The Woven EndoBridge (WEB) device (MicroVention, Aliso Viejo, California) is an intrasaccular flow disruptor used for the treatment of both unruptured and ruptured intracranial aneurysms. WEB has been shown to have 54% complete and 85% adequate aneurysm occlusion rates at 1-yr follow-up.1 Residual and recurrent ruptured aneurysms have been shown to have a higher risk of re-rupture than completely occluded aneurysms.2 With increased utilization of WEB in the United States, optimizing treatment strategies of residual aneurysms previously treated with the WEB device is essential, including surgical clipping.3,4 Here, we present an operative video demonstrating the surgical clip occlusion of previously ruptured middle cerebral artery and anterior communicating artery aneurysms that had been treated with the WEB device and had sizable recurrence on follow-up angiography. Informed consent was obtained from both patients. Lessons learned include the following: (1) the WEB device is highly compressible, unlike coils; (2) proximal WEB marker may interfere with clip closure; (3) no evidence of WEB extrusion into the subarachnoid space; (4) no more scarring than expected in ruptured cases; and (5) clipping is a feasible option for treating WEB recurrent or residual aneurysms.


2018 ◽  
Vol 11 (4) ◽  
pp. 386-389 ◽  
Author(s):  
Cristian Mihalea ◽  
Simon Escalard ◽  
Jildaz Caroff ◽  
Léon Ikka ◽  
Aymeric Rouchaud ◽  
...  

BackgroundWoven EndoBridge (WEB) deployment remains challenging in aneurysms with a complex shape or orientation.ObjectiveTo show that embolization of wide-neck bifurcation aneurysms using the WEB device balloon remodeling-assisted technique is a feasible and elegant endovascular solution compared with other techniques, such as balloon remodeling or stent-assisted coiling.Materials and methods10 cases (10 aneurysms in 9 patients) of balloon remodeling-assisted WEB treatment of unruptured complex bifurcation aneurysms were treated in our institution and retrospectively analyzed. Details of clinical presentations, technical details, perioperative and postoperative complications, and outcomes were collected. Immediate and long-term angiographic results were also evaluated.ResultsAneurysms included six middle cerebral artery aneurysms, one anterior communicating artery aneurysm, one posterior communicating artery aneurysm, one basilar artery aneurysm, and one T-shaped carotid aneurysm. Mean dome width was 6.55 mm, mean neck size 4.5 mm, mean height 4.79 mm, and mean dome-to-neck ratio was 1:1.46. Treatment was performed exclusively with the balloon remodeling-assisted WEB technique in all cases. The device was successfully deployed in every case. Periprocedural thromboembolic or hemorrhagic events did not occur. The modified Rankin Scale score at discharge was 0 for all patients. At mid-term or long-term angiographic follow-up, adequate occlusion was observed in 7 aneurysms from 8 controlled cases (87.5%), and one patient (2 aneurysms) did not have angiographic follow-up.ConclusionThe balloon remodeling-assisted WEB technique seems to be a safe and effective solution for endovascular treatment of unruptured wide-neck bifurcation aneurysms with specific complex anatomy. However, further studies are needed to evaluate the rate of complications and long-term efficacy.


2020 ◽  
pp. neurintsurg-2020-016405 ◽  
Author(s):  
Patrick P Youssef ◽  
David Dornbos III ◽  
Jeremy Peterson ◽  
Ahmad Sweid ◽  
Amanda Zakeri ◽  
...  

BackgroundWide-necked bifurcation aneurysms (WNBAs) present unique challenges for endovascular treatment. The Woven EndoBridge (WEB) device is an intrasaccular braided device, recently approved by the FDA for treatment of WNBAs. While treatment of intracranial aneurysms with the WEB device has been shown to yield an adequate occlusion rate of 85% at 1 year, few data have been published for patients with ruptured aneurysms.ObjectiveTo present a multi-institutional series depicting the safety and efficacy of using the WEB device as the primary treatment modality in ruptured intracranial aneurysms.MethodsA multi-institutional retrospective analysis was conducted, assessing patients presenting with aneurysmal subarachnoid hemorrhage treated with the WEB between January 2014 and April 2020. Baseline demographics, aneurysm characteristics, adverse events, and long-term outcomes (occlusion, re-treatment, functional status) were collected. A descriptive analysis was performed, and variables potentially associated with aneurysm recurrence or re-treatment were assessed.ResultsForty-eight patients were included. Anterior communicating artery aneurysms were the most common (35.4%) location for treatment, followed by middle cerebral artery (20.8%) and basilar apex (16.7%). Procedural success was noted in 95.8% of patients, and clinically significant periprocedural adverse events occurred in 12.5%. After a median follow-up of 5.5 months, 54.2% of patients had follow-up angiographic imaging. Complete occlusion was seen in 61.5% of cases with adequate occlusion in 92.3%. Re-treatment was required in only 4.2% of patients during the study period. Tobacco use was significantly higher in patients with aneurysm recurrence (88.9% vs 35.7%; p=0.012). No other characteristics were associated with recurrence/re-treatment. At 30 days, 81.1% were functionally independent (modified Rankin Scale score ≤2).ConclusionTreatment of acutely ruptured aneurysms with the WEB device demonstrates both safety and efficacy on par with rates of conventional treatment strategies.


Neurosurgery ◽  
2019 ◽  
Vol 66 (Supplement_1) ◽  
Author(s):  
Jorge A Roa ◽  
Mario Zanaty ◽  
Sudeepta Dandapat ◽  
Edgar Samaniego ◽  
Pascal Jabbour ◽  
...  

Abstract INTRODUCTION The Woven EndoBridge (WEB) device has recently emerged as an alternative to embolize complex intracranial aneurysms (IAs). However, there are limitations to the WEB device such as inability to secure acutely ruptured and wide-neck IAs. METHODS We conducted a retrospective analysis of our prospectively collected database of patients with IAs who underwent treatment with WEB device in conjunction with stenting and/or coiling, or WEB device placement in challenging locations. RESULTS A total of 7 patients/IAs were included. Average age was 59.3 ± 7.8 yr. All patients were women, and 2 presented with SAH. Two patients were treated with simultaneous stenting and WEB placement. One patient had a previous stent through which the WEB was placed. One patient underwent coiling, WEB and stent placement simultaneously. Another patient had a post-coiling recurring aneurysm which was treated with WEB placement. One patient was treated with WEB and coiling. One patient had an ophthalmic artery aneurysm with an acute angle treated with WEB alone. Two patients developed an asymptomatic decrease in flow in the parent vessel, which was successfully restored with the initiation of Tirofiban. One patient developed a herniation of the WEB device through the stent, requiring salvage with an expandable balloon that crushed the WEB against the stent and pushed it back to the aneurysm. No permanent complications or clinical deficits were reported after the endovascular procedures. The occlusion score was as follows: 4/7 cases (57.1%) achieved 100% occlusion, 2/7 cases (28.6%) had neck remnants, and 1 case (14.3%) had an aneurysmal remnant. One patient with severe SAH (Hunt & Hess grade IV) died due to no improvement in neurological exam and withdrawal of care. CONCLUSION WEB can be safely used in adjunct to coiling and/or stenting, or as a wire-navigation tool. Accurate sizing before deployment is critical.


2021 ◽  
pp. 1-7
Author(s):  
Nikolaos Mouchtouris ◽  
David Hasan ◽  
Edgar A. Samaniego ◽  
Fadi Al Saiegh ◽  
Ahmad Sweid ◽  
...  

OBJECTIVE Wide-neck bifurcation cerebral aneurysms have historically required either clip ligation or stent- or balloon-assisted coil embolization. This predicament led to the development of the Woven EndoBridge (WEB) aneurysm embolization system, a self-expanding mesh device that achieves intrasaccular flow disruption and does not require antithrombotic medications. The authors report their operative experience and 6-month follow-up occlusion outcomes with the first 115 aneurysms they treated via WEB embolization. METHODS The authors reviewed the first 115 cerebral aneurysms they treated by WEB embolization after FDA approval of the WEB embolization device (from February 2019 to January 2021). Data were collected on patient demographics and clinical presentation, aneurysm characteristics, procedural details, postembolization angiographic contrast stasis, and functional outcomes. RESULTS A total of 110 patients and 115 aneurysms were included in our study (34 ruptured and 81 unruptured aneurysms). WEB embolization was successful in 106 (92.2%) aneurysms, with a complication occurring in 6 (5.5%) patients. Contrast clearance was seen in the arterial phase in 14 (12.2%) aneurysms, in the capillary phase in 16 (13.9%), in the venous phase in 63 (54.8%), and no contrast was seen in 13 (11.3%) of the aneurysms studied. Follow-up angiography was performed on 60 (52.6%) of the aneurysms, with complete occlusion in 38 (63.3%), neck remnant in 14 (23.3%), and aneurysmal remnant in 8 (13.3%). Six (5.5%) patients required re-treatment for persistent aneurysmal residual on follow-up angiography. CONCLUSIONS The WEB device has been successfully used for the treatment of both unruptured and ruptured wide-neck bifurcation aneurysms by achieving intrasaccular flow diversion. Here, the authors have shared their experience with its unique technical considerations and device size selection, as well as critically reviewed complications and aneurysm occlusion rates.


2018 ◽  
Vol 128 (1) ◽  
pp. 144-153 ◽  
Author(s):  
Aimee Lawson ◽  
Andy Molyneux ◽  
Robin Sellar ◽  
Saleh Lamin ◽  
Allan Thomas ◽  
...  

OBJECTIVEThe Woven Endobridge (WEB) device has been in clinical use for the treatment of brain aneurysms for the past 4 years. Observational studies to assess clinical outcome and related complications have been published. Clear evidence is required to better understand the safety profile of the WEB device. The authors here present a multicenter series that provides a detailed safety analysis focused on patient selection, procedural events, and technical issues of treated patients throughout the United Kingdom (UK).METHODSA nationwide password-protected database was set up to collect anonymous information across the UK (14 centers). Complications and clinical outcome were analyzed for the initial 109 patients (112 procedures). An independent root cause analysis classified the complications into groups (procedural, disease, device, ancillary device, and other). The modified Rankin Scale (mRS) was used as a marker of clinical outcome.RESULTSEach of the 109 patients had 1 aneurysm suitable for WEB treatment (109 aneurysms). Three patients had 2 procedures, making a total of 112 procedures performed. Eight procedures were abandoned because of access issues; 2 patients went on to have a successful procedure. All 109 patients had a preprocedure and discharge mRS scores recorded. One hundred patients had a recorded mRS score from a > 3-month follow-up.Deployment of the WEB device was successful in 103 (94.5%) of 109 patients and 104 (92.9%) of 112 procedures. One patient had 2 successful WEB procedures on separate occasions. Patients without a successfully implanted WEB device were included in the analysis. Selection analysis showed that the average patient age was 56.5 years among 34 men and 75 women. The percentage of incidental aneurysms was 58.7%, acute 16.5%, symptomatic 18.3%, and recurrent 6.4%. Further results analysis showed that 40 (36.7%) of 109 patients had recorded adverse events, including those unrelated to the WEB device. Events that could be related to the WEB device numbered 17 (15.6%) among the 109 patients. Two patients with device-related complications were symptomatic. Overall, 11 patients (10.1%) had persistent clinical sequelae. Thromboembolism was the most prevalent event, affecting 15.6% of the patients (17 of 109), and 6.4% of the patients (7 of 109) with a thromboembolism were symptomatic.Overall mortality before discharge was 0% and at the > 3-month follow-up was 5% (5 of 100 patients). Morbidity was defined as an mRS score increase to > 2. Overall morbidity at discharge was 1.8% (2 of 109) and at the > 3-month follow-up was 6% (6 of 100). No device-related morbidity or mortality was associated with this group.CONCLUSIONSThe UK data show that the WEB device is safe for clinical use. Thromboembolic complication adds a risk that should be minimized with appropriate anticoagulation and correct sizing of the device. There is scope for further evaluation and standardization of an anticoagulation regimen for the WEB device.


2021 ◽  
pp. neurintsurg-2020-017105
Author(s):  
Gustavo M Cortez ◽  
Erinc Akture ◽  
Andre Monteiro ◽  
Adam S Arthur ◽  
Jeremy Peterson ◽  
...  

BackgroundThe Woven EndoBridge (WEB) device is approved in the USA for treatment of unruptured wide-neck bifurcation aneurysms. However, the safety and effectiveness of the WEB device in the treatment of ruptured intracranial aneurysms is not clear. We aim to evaluate the perioperative safety and effectiveness of the WEB device in patients with ruptured intracranial aneurysms.MethodsThis retrospective study, conducted at eight centers in the USA, included patients with ruptured intracranial aneurysms treated with the WEB device in the setting of subarachnoid hemorrhage (SAH). Safety outcomes included intraoperative complications such as vessel perforation, thromboembolic events, and postoperative hemorrhagic or thromboembolic complications based on radiologic imaging. The primary effectiveness outcome was adequate (complete and neck remnant) aneurysm occlusion, according to the Raymond–Roy classification.ResultsA total of 91 patients with 94 ruptured intracranial aneurysms were included (mean age 57.7±15.2 years; 68.1% women; 82.9% wide-necked). Aneurysms were located in the anterior communicating artery (42/94, 44.6%), middle cerebral artery (16/94, 17%), and basilar artery (15/94, 16%). Adequate occlusion was achieved in 48.8% (41/84) and 80.0% (40/50) at discharge and last follow-up (mean of 3.4 months), respectively. At discharge, procedural-related morbidity was 3.3% (3/91) and there was no procedure-related mortality. No re-rupture or delayed aneurysm rupture was observed.ConclusionsThis study demonstrates the perioperative safety and effectiveness of the WEB device for the treatment of patients with ruptured intracranial aneurysms in the setting of SAH, with low periprocedural morbidity and mortality. Long-term follow-up is warranted.


2017 ◽  
Vol 9 (12) ◽  
pp. 1191-1196 ◽  
Author(s):  
David Fiorella ◽  
Andrew Molyneux ◽  
Alexander Coon ◽  
Istvan Szikora ◽  
Isil Saatci ◽  
...  

IntroductionThe Woven EndoBridge (WEB) represents a novel intrasaccular therapeutic option for the treatment of intracranial wide-necked bifurcation aneurysms (WNBAs). The WEB-IT Study is a pivotal Investigational Device Exemption (IDE) study to determine the safety and effectiveness of the WEB device for the treatment of WNBAs located in the anterior and posterior intracranial circulations. We present the patient demographics, procedural characteristics, and 30-day adverse event data for the US WEB-IT study.MethodsWEB-IT is a prospective multicenter single-arm interventional study conducted at 25 US and 6 international centers. The study enrolled 150 adults with WNBAs of the anterior and posterior intracranial circulations. All patients were intended to receive a WEB device delivered via standard endovascular neurosurgical embolization techniques. The study was conducted under Good Clinical Practices and included independent adjudication effectiveness outcomes and all adverse events.ResultsOne hundred and fifty patients enrolled at 27 investigational sites underwent attempted treatment with the WEB. Mean age was 59 years (range 29–79) and 110 (73.3%) of the patients were female. Treated aneurysms were located at the basilar apex (n=59, 39.3%), middle cerebral artery bifurcation (n=45, 30%), anterior communicating artery (n=40, 26.7%), and internal carotid artery terminus (n=6, 4%). Average aneurysm size was 6.4 mm (range 3.6–11.4) with a mean neck size of 4.8 mm (range 2.0–8.2, mean dome to neck ratio 1.34). Nine patients presented with ruptured aneurysms. Of the enrolled patients, 98.7% were treated successfully with WEB devices. Mean±SD fluoroscopy time was 30.2±15.7 min. One primary safety event (PSE) (0.7%)—a delayed parenchymal hemorrhage 22 days after treatment—occurred between the index procedure and 30-day follow-up. In addition to the single PSE, there were seven (4.7%) minor ischemic strokes (5 resolved without sequelae and 2 had a modified Rankin Scale score of 1 at 30 days), five (2.7%) transient ischemic attacks, and two (1.3%) minor subarachnoid hemorrhages, which did not meet the prospectively established criteria for PSEs.ConclusionsThe WEB device can be used to treat WNBAs with a high level of procedural safety and a high degree of technical success.Trial registration numberNCT02191618; Pre-results.


Neurosurgery ◽  
2019 ◽  
Vol 66 (Supplement_1) ◽  
Author(s):  
Fadi Al Saiegh ◽  
David M Hasan ◽  
Nikolaos Mouchtouris ◽  
Mario Zanaty ◽  
Nohra Chalouhi ◽  
...  

Abstract INTRODUCTION Coiling has become the first-line treatment option for acutely ruptured aneurysms 1 to 3. However, coiling of wide-necked bifurcation aneurysms is challenging and stent-assisted coiling requires dual anti-platelet therapy. The Woven EndoBridge (WEB) flow disruptor has been recently Food and Drug Administration (FDA)-approved for bifurcation aneurysms and is designed to achieve intrasaccular flow diversion without the need for antiplatelet therapy. However, its use has been mostly reserved for unruptured aneurysms. Here, we present our series of ruptured aneurysms that were treated with the WEB-device post FDA approval. METHODS We performed a review of the first cohort of patients with acute subarachnoid hemorrhage (SAH) from ruptured aneurysms who underwent endovascular treatment with the WEB-device at Thomas Jefferson and Iowa University Hospitals and identified 7 patients. RESULTS All 7 patients were female and the mean age was 71 yr (range 57-81). Hunt and Hess grades ranged from 2 to 5. The aneurysms treated included anterior communicating, posterior communicating, posterior-inferior cerebellar (PICA), basilar apex, and vertebrobasilar junction (VBJ). In 6 of the 7 aneurysms, 1 WEB device was sufficient to achieve adequate obliteration; the VBJ aneurysm was 14 mm in size and required 2. The majority of patients underwent treatment via transfemoral access followed by transradial. One patient underwent direct carotid puncture due to vessel tortuosity. Aneurysm rebleeding was not encountered in any of the WEB-treated aneurysms. One patient had an intraoperative rupture of their PICA aneurysm after dislodgment of the WEB device. There were no treatment-related deaths, but one patient died of cardiopulmonary failure. CONCLUSION Our series shows that the WEB device can be safely used in ruptured bifurcation aneurysms of various sizes in the anterior and posterior circulation. It does not require adjunctive stent use and is a valuable alternative to stent-assisted coiling as it obviates the need for anti-platelet therapy.


Sign in / Sign up

Export Citation Format

Share Document