Posterior atlantoaxial facet screw fixation in rheumatoid arthritis

1998 ◽  
Vol 89 (1) ◽  
pp. 8-12 ◽  
Author(s):  
Mohammed Aly Eleraky ◽  
Roberto Masferrer ◽  
Volker K. H. Sonntag

Object. This retrospective review was conducted to determine the efficacy of transarticular screw fixation in a group of patients who were treated for rheumatoid atlantoaxial instability. Methods. Thirty-six patients (mean age 63 years) with rheumatoid atlantoaxial instability were treated with posterior atlantoaxial transarticular screw fixation supplemented with an interspinous C1–2 strut graft—cable construct to provide immediate three-point fixation to facilitate bone fusion. Previous attempts at fusions by using bone grafting with wire fixation at other institutions had failed in six of these patients. Six patients underwent transoral odontoid resections for removal of large irreducible pannus as a first-stage procedure, which was followed within 2 to 3 days by the posterior procedure. Postoperatively, 33 patients were placed in hard cervical collars and three required halo vests because of severe osteoporosis. Of eight patients categorized as Ranawat Class II preoperatively, all eight returned to normal after surgery; of eight patients in Ranawat Class III-A preoperatively, four improved to Class II and four remained unchanged. All 20 patients classified as Ranawat Class I preoperatively recovered completely. Pain decreased or resolved in all patients, and there were no complications related to instrumentation. At follow-up review (mean 2 years), 33 patients (92%) had solid bone fusions, and three (8%) had stable fibrous unions. Conclusions. Posterior atlantoaxial transarticular screw fixation provides a good surgical alternative for the management of patients with rheumatoid atlantoaxial instability. This technique provides immediate three-point rigid fixation of the C1–2 region, thus obviating the need for halo vest immobilization in most cases.

2000 ◽  
Vol 92 (1) ◽  
pp. 7-11 ◽  
Author(s):  
Douglas L. Brockmeyer ◽  
Julie E. York ◽  
Ronald I. Apfelbaum

Object. Craniovertebral instability is a challenging problem in pediatric spinal surgery. Recently, C1–2 transarticular screw fixation has been used to assist in craniovertebral joint stabilization in pediatric patients. Currently there are no available data that define the anatomical suitability of this technique in the pediatric population. The authors report their experience in treating 31 pediatric patients with craniovertebral instability by using C1–2 transarticular screws. Methods. From March 1992 to October 1998, 31 patients who were 16 years of age or younger with atlantooccipital or atlantoaxial instability, or both, were evaluated at our institution. There were 21 boys and 10 girls. Their ages ranged from 4 to 16 years (mean age 10.2 years). The most common causes of instability were os odontoideum (12 patients) and ligamentous laxity (eight patients). Six patients had undergone a total of nine previous attempts at posterior fusion while at outside institutions. All patients underwent extensive preoperative radiological evaluation including fine-slice (1-mm) computerized tomography scanning with multiplanar reconstruction to evaluate the anatomy of the C1–2 joint space. Preoperatively, of the 62 possible C1–2 joint spaces in 31 patients, 55 sides (89%) were considered suitable for transarticular screw placement. In three patients the anatomy was considered unsuitable for bilateral screw placement. In three patients the anatomy was considered inadequate on one side. Fifty-five C1–2 transarticular screws were subsequently placed, and there were no neurological or vascular complications. Conclusions. The authors conclude that C1–2 transarticular screw fixation is technically possible in a large proportion of pediatric patients with craniovertebral instability.


1993 ◽  
Vol 79 (2) ◽  
pp. 234-237 ◽  
Author(s):  
Paul Marcotte ◽  
Curtis A. Dickman ◽  
Volker K. H. Sonntag ◽  
Dean G. Karahalios ◽  
Janine Drabier

✓ Eighteen patients with atlantoaxial instability were treated with posterior atlantoaxial facet screws to obtain immediate rigid fixation of C1–2. Of these 18 patients, instability occurred due to trauma in nine, rheumatoid arthritis in six, neoplasms in two, and os odontoideum in one. Four patients presented with nonunion after failed C1–2 wire and graft procedures. In all cases in this series the screw fixations were augmented with an interspinous C1–2 strut graft which was wired in place to provide three-point stabilization and to facilitate bone fusion. In every case fixation was satisfactory, and C1–2 alignment and stability were restored without complications due to instrumentation. One patient died 3 months postoperatively from metastatic tumor; the spinal fixation was intact. All 17 surviving patients have developed osseous unions (mean follow-up period 12 months, range 6 to 16 months). Posterior atlantoaxial facet screw fixation provides immediate multidirectional rigid fixation of C1–2 that is mechanically superior to wiring or clamp fixation. This technique maximizes success without the need for a supplemental rigid external orthosis, and is particularly useful for pseudoarthrosis.


1996 ◽  
Vol 85 (2) ◽  
pp. 221-224 ◽  
Author(s):  
Christopher G. Paramore ◽  
Curtis A. Dickman ◽  
Volker K. H. Sonntag

✓ Posterior transarticular screw fixation of the C1–2 complex has become an accepted method of rigid internal fixation for patients requiring posterior C1–2 fusion. The principal limitation of this procedure is the location of the vertebral artery, because an anomalous position may prohibit screw placement. In this study, a consecutive series of computerized tomography (CT) scans was reviewed, and the suitability of each patient for transarticular screw fixation was evaluated. All of the fine-slice axial C1–2 CT scans and reconstructions performed on a spiral scanner over 2 years were reviewed. A novel screw trajectory reconstruction was designed to visualize the potential path of a transarticular screw in the plane of the reconstruction. Scans were reviewed for bone anatomy and the position of the transverse foramen. Seventeen (18%) of 94 patients had a high-riding transverse foramen on at least one side of the C-2 vertebra that would prohibit the placement of transarticular screws. The left side was involved in nine patients and the right in five. Three patients had bilateral anomalies. The mean age of the group with anomalies (35.9 years, range 10–76) was not significantly different from the overall mean age (35.7 years, range 6–94). An additional five patients (5%) were considered to have anatomy in which screw placement was feasible but risky. On the basis of these data, it is postulated that 18% to 23% of patients may not be suitable candidates for posterior C1–2 transarticular screw fixation on at least one side.


2005 ◽  
Vol 2 (2) ◽  
pp. 164-169 ◽  
Author(s):  
Wayne M. Gluf ◽  
Douglas L. Brockmeyer

Object. In this, the second of two articles regarding C1–2 transarticular screw fixation, the authors discuss their surgical experience in treating patients 16 years of age and younger, detailing the rate of fusion, complication avoidance, and lessons learned in the pediatric population. Methods. The authors retrospectively reviewed 67 consecutive patients (23 girls and 44 boys) younger than 16 years of age in whom at least one C1–2 transarticular screw fixation procedure was performed. A total of 127 transarticular screws were placed in these 67 patients whose mean age at time of surgery was 9 years (range 1.7–16 years). The indications for surgery were trauma in 24 patients, os odontoideum in 22 patients, and congenital anomaly in 17 patients. Forty-four patients underwent atlantoaxial fusion and 23 patients underwent occipitocervical fusion. Two of the 67 patients underwent halo therapy postoperatively. All patients were followed for a minimum of 3 months. In all 67 patients successful fusion was achieved.Complications occurred in seven patients (10.4%), including two vertebral artery injuries. Conclusions. The use of C1–2 transarticular screw fixation, combined with appropriate atlantoaxial and craniovertebral bone/graft constructs, resulted in a 100% fusion rate in a large consecutive series of pediatric patients. The risks of C1–2 transarticular screw fixation can be minimized in this population by undertaking careful patient selection and meticulous preoperative planning.


2003 ◽  
Vol 98 (1) ◽  
pp. 73-76 ◽  
Author(s):  
Do Heum Yoon ◽  
Kook Hee Yang ◽  
Keung Nyun Kim ◽  
Sung Han Oh

✓ Posterior dislocation of the atlas onto the axis without related fracture of the odontoid process is a very rare traumatic condition of which five cases have been previously reported. The authors present a sixth case in which management was different from the others. The patient was successfully treated by open reduction of the dislocation and C1–2 transarticular screw fixation. The rarity of the lesion, the differences in diagnostic studies, and the successful treatment by safe intraoperative reduction and fixation are factors of interest in this case.


2002 ◽  
Vol 97 (1) ◽  
pp. 123-127 ◽  
Author(s):  
Masashi Neo ◽  
Mutsumi Matsushita ◽  
Tadashi Yasuda ◽  
Takeshi Sakamoto ◽  
Takashi Nakamura

✓ Posterior atlantoaxial transarticular screw fixation is an excellent procedure associated with high fusion rates. There is, however, the potential risk of vertebral artery (VA) injury. The authors designed a special aiming device that allows a cannulated screw to be inserted accurately in the most posterior part of the C1–2 joint via the most posterior and medial part of the isthmus of C-2; this screw pathway most safely avoids VA injury. The instruments include an aiming device and a flexible screw-inserting system. The tip of the aiming device is placed on the ridge of the C-2 isthmus just posterior to the atlantoaxial joint. The guide wire should then pass 1 mm below the device tip. The system consists of flexible guide wires, a drill, a tap, and a screwdriver, and the screw is inserted easily via a posterior approach in which the patient's back is not obstructive. Ten patients with atlantoaxial subluxation or osteoarthritis underwent surgery in which the device was used. In all cases, the screws were inserted safely without causing VA injury, although preoperative computerized tomography (CT) reconstructions revealed a high-risk high-riding unilateral VA in three patients. Postoperative CT reconstructions demonstrated that all screws but one were inserted as planned, and successfully cleared the vertebral groove. In conclusion, this newly designed device is practical and useful for the accurate insertion of screws, thus avoiding VA injury during atlantoaxial transarticular screw fixation.


2002 ◽  
Vol 97 (3) ◽  
pp. 400-402 ◽  
Author(s):  
Douglas L. Brockmeyer

✓ A new technique for performing a posterior rib and multistranded cable atlantoaxial fusion in children is described. The technique has been used successfully, in two patients 22 and 18 months of age, respectively. In both cases, fusion was used to augment C1–2 transarticular screw fixation, and solid arthrodesis was achieved without a halo orthosis.


2006 ◽  
Vol 5 (2) ◽  
pp. 172-177 ◽  
Author(s):  
Eric M. Horn ◽  
Jonathan S. Hott ◽  
Randall W. Porter ◽  
Nicholas Theodore ◽  
Stephen M. Papadopoulos ◽  
...  

✓ Atlantoaxial stabilization has evolved from simple posterior wiring to transarticular screw fixation. In some patients, however, the course of the vertebral artery (VA) through the axis varies, and therefore transarticular screw placement is not always feasible. For these patients, the authors have developed a novel method of atlantoaxial stabilization that does not require axial screws. In this paper, they describe the use of this technique in the first 10 cases. Ten consecutive patients underwent the combined C1–3 lateral mass–sublaminar axis cable fixation technique. The mean age of the patients was 62.6 years (range 23–84 years). There were six men and four women. Eight patients were treated after traumatic atlantoaxial instability developed (four had remote trauma and previous nonunion), whereas in the other two atlantoaxial instability was caused by arthritic degeneration. All had VA anatomy unsuitable to traditional transarticular screw fixation. There were no intraoperative complications in any of the patients. Postoperative computed tomography studies demonstrated excellent screw positioning in each patient. Nine patients were treated postoperatively with the aid of a rigid cervical orthosis. The remaining patient was treated using a halo fixation device. One patient died of respiratory failure 2 months after surgery. Follow-up data (mean follow-up duration 13.1 months) were available for seven of the remaining nine patients and demonstrated a stable construct with fusion in each patient. The authors present an effective alternative method in which C1–3 lateral mass screw fixation is used to treat patients with unfavorable anatomy for atlantoaxial transarticular screw fixation. In this series of 10 patients, the method was a safe and effective way to provide stabilization in these anatomically difficult patients.


2005 ◽  
Vol 2 (2) ◽  
pp. 175-181 ◽  
Author(s):  
Jonathan S. Hott ◽  
James J. Lynch ◽  
Robert H. Chamberlain ◽  
Volker K. H. Sonntag ◽  
Neil R. Crawford

Object. In a nondestructive, repeated-measures in vitro flexibility experiment, the authors compared the acute stability of C1–2 after placement of C-1 lateral mass and C-2 pars interarticularis (LC1—PC2) instrumentation with that of C1–2 transarticular screw fixation. Methods. The effect of C-1 laminectomy and C1–2 interspinous cable/graft fixation on LC1—PC2 stability was studied. Screw pullout strengths were also compared. Seven human cadaveric occiput—C3 specimens were loaded nondestructively with pure moments while measuring nonconstrained atlantoaxial motion. Specimens were tested with graft alone, LC1—PC2 alone, LC1—PC2 combined with C-1 laminectomy, and graft-augmented LC1—PC2. Interspinous cable/graft fixation significantly enhanced LC1—PC2 stability during extension. After C-1 laminectomy, the LC1—PC2 construct allowed increased motion during flexion and extension. There was no significant difference in lax zone or range of motion between LC1—PC2 fixation and transarticular screw fixation, but graft-assisted transarticular screws yielded a significantly smaller stiff zone during extension. The difference in pullout resistance between C-1 lateral mass screws and C-2 pars interarticularis screws was insignificant. The LC1—PC2 region restricted motion to within the normal range during all loading modes. Atlantal laminectomy reduced LC1—PC2 stability during flexion and extension. Conclusions. The instrumentation-augmented LC1—PC2 construct performed biomechanically similarly to the C1–2 transarticular screw fixation. The LC1—PC2 construct resisted flexion, lateral bending, and axial rotation well. The weakness of the LC1—PC2 fixation in resisting extension can be overcome by adding an interspinous graft to the construct.


1997 ◽  
Vol 86 (6) ◽  
pp. 961-968 ◽  
Author(s):  
Ali Abou Madawi ◽  
Adrian T. H. Casey ◽  
Guirish A. Solanki ◽  
Gerald Tuite ◽  
Robert Veres ◽  
...  

✓ Sixty-one patients treated with C1–2 transarticular screw fixation for spinal instability participated in a detailed clinical and radiological study to determine outcome and clarify potential hazards. The most common condition was rheumatoid arthritis (37 patients) followed by traumatic instability (15 patients). Twenty-one of these patients (onethird) underwent either surgical revision for a previously failed posterior fusion technique or a combined anteroposterior procedure. Eleven patients underwent transoral odontoidectomy and excision of the arch of C-1 prior to posterior surgery. No patient died, but there were five vertebral artery (VA) injuries and one temporary cranial nerve palsy. Screw malposition (14% of placements) was comparable to another large series reported by Grob, et al. There were five broken screws, and all were associated with incorrect placement. Anatomical measurements were made on 25 axis bones. In 20% the VA groove on one side was large enough to reduce the width of the C-2 pedicle, thus preventing the safe passage of a 3.5-mm diameter screw. In addition to the obvious dangers in patients with damaged or deficient atlantoaxial lateral mass, the following risk factors were identified in this series: 1) incomplete reduction prior to screw placement, accounting for two-thirds of screw complications and all five VA injuries; 2) previous transoral surgery with removal of the anterior tubercle or the arch of the atlas, thus obliterating an important fluoroscopic landmark; and 3) failure to appreciate the size of the VA in the axis pedicle and lateral mass. A low trajectory with screw placement below the atlas tubercle was found in patients with VA laceration. The technique that was associated with an 87% fusion rate requires detailed computerized tomography scanning prior to surgery, very careful attention to local anatomy, and nearly complete atlantoaxial reduction during surgery.


Sign in / Sign up

Export Citation Format

Share Document