scholarly journals Endovascular Treatment of Intracranial Aneurysms with the WEB Device: A Systematic Review of Clinical Outcomes

2015 ◽  
Vol 37 (5) ◽  
pp. 868-872 ◽  
Author(s):  
X. Armoiry ◽  
F. Turjman ◽  
D. J. Hartmann ◽  
R. Sivan-Hoffmann ◽  
R. Riva ◽  
...  
2015 ◽  
Vol 21 (4) ◽  
pp. 462-469 ◽  
Author(s):  
Patricia Bozzetto Ambrosi ◽  
Benjamin Gory ◽  
Rotem Sivan-Hoffmann ◽  
Roberto Riva ◽  
Francesco Signorelli ◽  
...  

Background The WEB device is a recent intrasaccular flow disruption technique developed for the treatment of wide-necked intracranial aneurysms. To date, a single report on the WEB Single-Layer (SL) treatment of intracranial aneurysms has been published with 1-months' safety results. The aim of this study is to report our experience and 6-month clinical and angiographic follow-up of endovascular treatment of wide-neck aneurysm with the WEB SL. Methods Ten patients with 10 unruptured wide-necked aneurysms were prospectively enrolled in this study. Feasibility, intraoperative and postoperative complications, and outcomes were recorded. Immediate and 6-month clinical and angiographic results were evaluated. Results Failure of WEB SL placement occurred in two cases. Eight aneurysms were successfully treated using one WEB SL without additional treatment. Three middle cerebral artery, four anterior communicating artery, and one basilar artery aneurysms were treated. Average dome width was 7.5 mm (range 5.4–10.7 mm), and average neck size was 4.9 mm (range 2.6–6.5 mm). No periprocedural complication was observed, and morbi-mortality at discharge and 6 months was 0.0%. Angiographic follow-up at 6 months demonstrated complete aneurysm occlusion in 2/8 aneurysms, neck remnant in 5/8 aneurysms, and aneurysm remnant in 1/8 aneurysm. Conclusions From this preliminary study, treatment of bifurcation intracranial aneurysms using WEB SL is feasible. WEB SL treatment seems safe at 6 months; however, the rate of neck remnants is not negligible due to compression of the WEB SL. Further technical improvements may be needed in order to ameliorate the occlusion in the WEB SL treatment.


2020 ◽  
pp. neurintsurg-2020-016405 ◽  
Author(s):  
Patrick P Youssef ◽  
David Dornbos III ◽  
Jeremy Peterson ◽  
Ahmad Sweid ◽  
Amanda Zakeri ◽  
...  

BackgroundWide-necked bifurcation aneurysms (WNBAs) present unique challenges for endovascular treatment. The Woven EndoBridge (WEB) device is an intrasaccular braided device, recently approved by the FDA for treatment of WNBAs. While treatment of intracranial aneurysms with the WEB device has been shown to yield an adequate occlusion rate of 85% at 1 year, few data have been published for patients with ruptured aneurysms.ObjectiveTo present a multi-institutional series depicting the safety and efficacy of using the WEB device as the primary treatment modality in ruptured intracranial aneurysms.MethodsA multi-institutional retrospective analysis was conducted, assessing patients presenting with aneurysmal subarachnoid hemorrhage treated with the WEB between January 2014 and April 2020. Baseline demographics, aneurysm characteristics, adverse events, and long-term outcomes (occlusion, re-treatment, functional status) were collected. A descriptive analysis was performed, and variables potentially associated with aneurysm recurrence or re-treatment were assessed.ResultsForty-eight patients were included. Anterior communicating artery aneurysms were the most common (35.4%) location for treatment, followed by middle cerebral artery (20.8%) and basilar apex (16.7%). Procedural success was noted in 95.8% of patients, and clinically significant periprocedural adverse events occurred in 12.5%. After a median follow-up of 5.5 months, 54.2% of patients had follow-up angiographic imaging. Complete occlusion was seen in 61.5% of cases with adequate occlusion in 92.3%. Re-treatment was required in only 4.2% of patients during the study period. Tobacco use was significantly higher in patients with aneurysm recurrence (88.9% vs 35.7%; p=0.012). No other characteristics were associated with recurrence/re-treatment. At 30 days, 81.1% were functionally independent (modified Rankin Scale score ≤2).ConclusionTreatment of acutely ruptured aneurysms with the WEB device demonstrates both safety and efficacy on par with rates of conventional treatment strategies.


2017 ◽  
Vol 10 (2) ◽  
pp. 127-132 ◽  
Author(s):  
Benjamin Mine ◽  
Alexandra Goutte ◽  
Denis Brisbois ◽  
Boris Lubicz

PurposeTo evaluate the clinical and anatomical results of treatment of intracranial aneurysms (IA) with the Woven EndoBridge (WEB) device, with emphasis on mid term and long term follow-up.MethodsBetween November 2010 and November 2015, we retrospectively identified, in our prospectively maintained database, all patients treated by WEB device placement for an IA at three institutions. Clinical charts, procedural data, and angiographic results were reviewed.Results48 patients with 49 IAs were identified. There were 35 women and 13 men with a mean age of 57 years (range 35–76 years). All IA were wide necked. Mean aneurysm size was 8.6 mm. There were 44 unruptured IA and 5 ruptured IA. During endovascular treatment (EVT), adjunctive devices were used in 22.4% of procedures. A good clinical outcome (modified Rankin Scale score ≤2) was achieved in 44/48 patients (92%). There was no mortality. Mean follow-up was 25 months (range 3–72 months; median 24 months). Between mid term and long term follow-up, occlusion was stable in 19/23 IA (82.6%), improved in 2/23 IA (8.7%), and worsened in 2/23 IA (8.7%). Retreatment was performed in 8/49 IA (16.3%). At the latest available follow-up, there were 34/47 (72.3%) complete occlusions and 13/47 (27.7%) neck remnants.ConclusionsOur study suggests that EVT of IA with the WEB device provides adequate and stable long term occlusion.


2015 ◽  
Vol 8 (5) ◽  
pp. e18-e18 ◽  
Author(s):  
Joe Joseph Leyon ◽  
Swarupsinh Chavda ◽  
Saleh Lamin

The WEB is an endovascular flow-disrupting device used in treating wide-necked intracranial aneurysms. Although the device is available in varying sizes, large aneurysms pose a challenge with the need for custom-made devices. We describe the use of coils as an adjunct to the WEB device in successfully treating large aneurysms in two patients, one with an acutely ruptured aneurysm. This novel technique of jailing a microcatheter, deploying the WEB and then coiling the aneurysm saves the need for intracranial stenting, thereby avoiding the need for antiplatelet therapy, which is of benefit in the setting of acute aneurysm rupture.


Author(s):  
Laurent Pierot

Intrasaccular flow disruption is an innovative approach for the endovascular treatment of intracranial aneurysms. As of now, only one device is currently available worldwide: the Woven EndoBridge (WEB) device (MicroVention, Aliso Viejo, CA, USA). After 10 years of clinical use and careful clinical evaluation of the WEB device by multiple prospective, multicenter studies, this article is summarizing the current knowledge regarding this endovascular technique; indications, modalities, safety and efficacy of the WEB procedure are described.


2020 ◽  
pp. 159101992097384
Author(s):  
Timothy G White ◽  
Kevin Shah ◽  
Justin Turpin ◽  
Thomas Link ◽  
Amir R Dehdashti ◽  
...  

Introduction The concurrent use of endoluminal flow diversion with coils is a viable option when treating complex or large aneurysms. Alternatives to coil embolization as an adjunctive treatment are currently limited. The Food and Drug Administration recently approved the Woven EndoBridge (WEB) device (Microvention, Aliso Viejo, California) as an intrasaccular flow diverter for wide-neck bifurcation aneurysms. We present the technical aspects of combined WEB device plus endoluminal flow diversion for the treatment of complex wide-necked intracranial aneurysms. Methods A retrospective chart review of all patients treated via intrasaccular flow diversion at a single institution over the last 12 months was performed. Results In total, seven patients underwent treatment of eight aneurysms via combined intrasaccular and endoluminal flow diversion. Of the seven patients, six were treated in a single setting. The most common aneurysm location was the posterior communicating artery. The majority of the aneurysms required steam shaping of the Via deployment catheter to place the WEB device orthogonally to the aneurysm dome. There were no complications. Conclusions We believe this is one of the first series reporting the combined use of the WEB device and endoluminal flow diversion for the treatment of intracranial aneurysms. This series demonstrates that the concurrent use of the WEB device with endoluminal flow diversion is safe for achieving immediate aneurysm treatment and may enhance the long-term durability in complex aneurysms.


2013 ◽  
Vol 19 (2) ◽  
pp. 195-202 ◽  
Author(s):  
A. Consoli ◽  
G. Grazzini ◽  
L. Renieri ◽  
A. Rosi ◽  
A. De Renzis ◽  
...  

Despite the encouraging results obtained with the endovascular treatment of ruptured intracranial aneurysms, few data are available on the effects of the timing of this approach on clinical outcome. The aim of our study was to evaluate the effects of the hyper-early timing of treatment and of pre-treatment and treatment-related variables on the clinical outcome of patients with ruptured intracranial aneurysms. Five hundred and ten patients (167 M, 343 F; mean age 56.45 years) with 557 ruptured intracranial aneurysms were treated at our institution from 2000 to 2011 immediately after their admission. The total population was divided into three groups: patients treated within 12 hours (hyper-early, group A), between 12–48 hours (early, group B) and after 48 hours (delayed, group C). A statistical analysis was carried out for global population and subgroups. Two hundred and thirty-four patients (46%) were included in group A, 172 (34%) in group B and 104 (20%) in group C. Pre-treatment variables (Hunt&Hess, Fisher grades, older age) and procedure-related variable (ischaemic/haemorrhagic complications) showed a significant correlation with worse clinical outcomes. The hyper-early treatment showed no correlation with good clinical outcomes. The incidence of intraprocedural complications was not significantly different between the three groups; 1.2% of pre-treatment rebleedings were observed. The hyper-early endovascular treatment of ruptured intracranial aneurysm does not seem to be statistically correlated with good clinical outcomes although it may reduce the incidence of pre-treatment spontaneous rebleedings without being associated with a higher risk of intraprocedural complications. However, since no significant differences in terms of clinical outcome and pre-treatment rebleeding rate were observed, a hyper-early treatment is not be supported by our data.


Sign in / Sign up

Export Citation Format

Share Document