A case of rib fracture detected by breast ultrasound examination

Choonpa Igaku ◽  
2020 ◽  
Author(s):  
Ayami SHIMIZU ◽  
Yuko HASHIMOTO ◽  
Tsuyoshi TABATA ◽  
Kazuhiro SHIMIZU ◽  
Nobuo TAKADA
2021 ◽  
Vol 64 (10) ◽  
pp. 671-677
Author(s):  
Su Min Ha ◽  
Jung Min Chang

Background: Coronavirus disease 2019 (COVID-19) vaccine-induced lymphadenopathy is a critical side effect that should be a concern to clinicians, patients, radiologists, and oncologists. Vaccine-induced lymphadenopathy causes a diagnostic dilemma, especially for breast radiologists who examine both axillary regions during breast ultrasound examinations. Appropriate imaging guidelines are needed to manage vaccine-induced lymphadenopathy for patients undergoing screening examinations or symptomatic patients, including cancer patients.Current Concepts: For patients with axillary lymphadenopathy in the setting of recent ipsilateral vaccination, clinical follow-up is recommended. In other scenarios, short-term follow-up axillary ultrasound examinations are recommended if the clinical concerns persist for more than 6 weeks after vaccination. To mitigate the diagnostic dilemma of vaccine-induced lymphadenopathy, patients should schedule screening imaging examinations before the first vaccination or at least six weeks following the second vaccination. For clinicians and radiologists, documenting the patients’ vaccination status is critical to decreasing unnecessary follow-up imaging, biopsies, and patient’s anxiety.Discussion and Conclusion: Our proposal can help reduce patient anxiety, provider burden, and costs of unnecessary evaluation of enlarged lymph nodes in the setting of recent COVID-19 vaccination. Further, it can avoid delays in vaccination and breast cancer screening during the COVID-19 pandemic.


2020 ◽  
Vol 0 (0) ◽  
pp. 0
Author(s):  
SaraDe Giorgis ◽  
Nicole Brunetti ◽  
Jeries Zawaideh ◽  
Federica Rossi ◽  
Massimo Calabrese ◽  
...  

2017 ◽  
Vol 43 ◽  
pp. S18
Author(s):  
Eriko Tohno ◽  
Setsuko Kaoku ◽  
Takanori Watanabe ◽  
Toshitaka Okuno ◽  
Takuhiro Yamaguchi ◽  
...  

Author(s):  
Takanori Watanabe ◽  
Takuhiro Yamaguchi ◽  
Eriko Tohno ◽  
Hiroko Tsunoda ◽  
Setsuko Kaoku ◽  
...  

Abstract Purpose Breast ultrasound has been widely used as an essential examination for diagnosing breast cancer. However, standardized diagnostic criteria are as yet lacking. This study aimed to develop a simple diagnostic flowchart for beginners learning breast ultrasonography. The diagnostic flowchart was developed based on the recall criteria widely used in Japan. Methods We conducted a multicenter study to examine recall criteria usefulness in the diagnostic phase of breast disease. Women with ultrasound-visible breast masses who underwent B-mode breast ultrasound examination were recruited from 22 hospitals in Japan between September 2009 and January 2010. B-mode images were evaluated by members of the centralized image interpretation committee. We developed the new diagnostic flowchart based on the results. The usefulness of the diagnostic flowchart was assessed by employing datasets from the current study and another study which we conducted (BC-04 study). Results We evaluated 1045 solid masses (malignant: 495, benign: 550). Multivariate analysis showed that shape, margin, echogenic halo, interruption of the mammary gland interface, and depth width ratio were significant findings for distinguishing between benign and malignant masses. We modified the recall criteria and developed our novel diagnostic flowchart using these findings. The sensitivity and specificity of the new flowchart (current study: 0.97, 0.45; BC-04 study dataset: 0.95, 0.45) were similar to those of experts (current study: 0.96, 0.54; BC-04 study dataset: 0.98, 0.38). Conclusion We developed a simple diagnostic flowchart for breast ultrasound. This flowchart is anticipated to be applicable to educating beginners learning breast ultrasound.


Author(s):  
Yasser I. Abd Elkhalek ◽  
Ahmed M. Bassiouny ◽  
Rasha Wessam Abdel Rahman Abdel Hamid

Abstract Background Mammography is the most accepted, accurate, and effective modality in screening of breast cancer, yet its sensitivity is affected by the density of the breast tissue. Alternative methods for screening are the sonography and MRI but both had their limitations. A new option named ABUS (automated breast ultrasound system) is now proposed to overcome the breast US limitation as it is time-consuming and operator-dependent and to overcome the costly time-consuming MRI. The objectives of the study are to evaluate the accuracy of ABUS in the detection of different breast lesions as a substitution for mammography. This prospective study included 25 women outreached for digital mammography or handheld ultrasound examination at the period between January 2017 and February 2018. Women have no specific age group. Results Significant improvement in the detection of breast lesions by ABUS use with mammogram especially in dense breasts (ACR class C and D) Conclusion ABUS is a promising competitor to mammogram in screening of breast lesions


Sign in / Sign up

Export Citation Format

Share Document