A compact guided-wave EMAT with pulsed electromagnet for ferromagnetic tube inspection

2020 ◽  
Vol 64 (1-4) ◽  
pp. 951-958
Author(s):  
Tianhao Liu ◽  
Yu Jin ◽  
Cuixiang Pei ◽  
Jie Han ◽  
Zhenmao Chen

Small-diameter tubes that are widely used in petroleum industries and power plants experience corrosion during long-term services. In this paper, a compact inserted guided-wave EMAT with a pulsed electromagnet is proposed for small-diameter tube inspection. The proposed transducer is noncontact, compact with high signal-to-noise ratio and unattractive to ferromagnetic tubes. The proposed EMAT is designed with coils-only configuration, which consists of a pulsed electromagnet and a meander pulser/receiver coil. Both the numerical simulation and experimental results validate its feasibility on generating and receiving L(0,2) mode guided wave. The parameters for driving the proposed EMAT are optimized by performance testing. Finally, feasibility on quantification evaluation for corrosion defects was verified by experiments.

Author(s):  
Achilles Vairis ◽  
Suzana Brown ◽  
Maurice Bess ◽  
Kyu Hyun Bae ◽  
Jonathan Boyack

Enhancing gait stability in people who use crutches is paramount for their health. With the significant difference in gait compared to users who do not require an assistive device, the use of standard gait analysis tools to measure movement for temporary crush users and physically disabled people proves to be more challenging. In this paper, a novel approach based on video analysis is proposed as non-contact low-cost solution to the more expensive alternative with the data collected from processed videos, two values are calculated: the Signal to Noise Ratio (SNR) of acceleration, and the Signal to Noise Ratio of the jerk (time derivative of acceleration), to assess the user’s stability while they walk with crutches. The adopted methodology has been tested on a total of 10 participants. Five are temporary users of assistive devices with one being a long-term user and the other four novice users, and five are disabled participants who use those assistive devices permanently. Preliminary results show differences between novice users, long-term users, and physically disabled users. The approach is promising and could improve the assessment of crutch user stability, allowing for the correction of gait for individuals while using an inexpensive non-contact setup and preventing unnecessary falls.


Nanophotonics ◽  
2020 ◽  
Vol 9 (10) ◽  
pp. 3443-3450 ◽  
Author(s):  
Wei-Nan Liu ◽  
Rui Chen ◽  
Wei-Yi Shi ◽  
Ke-Bo Zeng ◽  
Fu-Li Zhao ◽  
...  

AbstractSelective transmission or filtering always responds to either frequency or incident angle, so as hardly to maximize signal-to-noise ratio in communication, detection and sensing. Here, we propose compact meta-filters of narrow-frequency sharp-angular transmission peak along with broad omnidirectional reflection sidebands, in all-dielectric cascaded subwavelength meta-gratings. The inherent collective resonance of waveguide-array modes and thin film approximation of meta-grating are employed as the design strategy. A unity transmission peak, locating at the incident angle of 44.4° and the center wavelength of 1550 nm, is demonstrated in a silicon meta-filter consisting of two-layer silicon rectangular meta-grating. These findings provide possibilities in cascaded meta-gratings spectroscopic design and alternative utilities for high signal-to-noise ratio applications in focus-free spatial filtering and anti-noise systems in telecommunications.


2016 ◽  
Vol 7 (2) ◽  
pp. 381 ◽  
Author(s):  
Lukas B. Gromann ◽  
Dirk Bequé ◽  
Kai Scherer ◽  
Konstantin Willer ◽  
Lorenz Birnbacher ◽  
...  

2014 ◽  
Vol 556-562 ◽  
pp. 6328-6331
Author(s):  
Su Zhen Shi ◽  
Yi Chen Zhao ◽  
Li Biao Yang ◽  
Yao Tang ◽  
Juan Li

The LIFT technology has applied in process of denoising to ensure the imaging precision of minor faults and structure in 3D coalfield seismic processing. The paper focused on the denoising process in two study areas where the LIFT technology is used. The separation of signal and noise is done firstly. Then denoising would be done in the noise data. The Data of weak effective signal that is from the noise data could be blended with the original effective signal to reconstruct the denoising data, so the result which has high signal-to-noise ratio and preserved amplitude is acquired. Thus the fact shows that LIFT is an effective denoising method for 3D seismic in coalfield and could be used widely in other work area.


2013 ◽  
Vol 770 ◽  
pp. 319-322 ◽  
Author(s):  
Piya Kovintavewat ◽  
Santi Koonkarnkhai ◽  
Aimamorn Suvichakorn

During hard disk drive (HDD) testing process, the magneto-resistive read (MR) head is analyzed and checked if the head is defective or not. Baseline popping (BLP) is one of the crucial problems caused by head instability, whose effect can distort the readback signal to the extent of causing possible sector read failure. Without BLP detection algorithm, the defective read head might pass through HDD assembling process, thus producing an unreliable HDD. This situation must be prevented so as to retain customer satisfaction. This paper proposes a simple (but efficient) BLP detection algorithm for perpendicular magnetic recording systems. Results show that the proposed algorithm outperforms the conventional one in terms of both the percentage of detection and the percentage of false alarm, when operating at high signal-to-noise ratio.


2006 ◽  
Author(s):  
Stanley Wissmar ◽  
Linda Höglund ◽  
Jan Andersson ◽  
Christian Vieider ◽  
Susan Savage ◽  
...  

1976 ◽  
Vol 66 (6) ◽  
pp. 1887-1904
Author(s):  
J. F. Evernden ◽  
W. M. Kohler

abstract A possibly significant factor in application of an identification criterion such as MS:mb is systematic bias in mb magnitude estimates at small magnitudes due to a variety of factors. Magnitude bias is the difference in magnitude value, positive or negative, between an observed network-based magnitude value and the expected magnitude value if all stations of the network had detected the event at high signal-to-noise ratio. This paper constitutes a partial study of the general problem; it evaluates the bias effects expected from both conceptual and operational networks when using parameters for noise and signal levels and standard deviations derived from observations, and when correcting observed station mb values solely via a simple parameter station correction factor. The analysis shows that any bias effects on mb inherent in any operational or potential worldwide network are so small as to have negligible effect on use of an MS:mb discriminant.


Sign in / Sign up

Export Citation Format

Share Document