Automatic tooth roots segmentation of cone beam computed tomography image sequences using U-net and RNN

2020 ◽  
Vol 28 (5) ◽  
pp. 905-922
Author(s):  
Qingqing Li ◽  
Ke Chen ◽  
Lin Han ◽  
Yan Zhuang ◽  
Jingtao Li ◽  
...  

BACKGROUND: Automatic segmentation of individual tooth root is a key technology for the reconstruction of the three-dimensional dental model from Cone Beam Computed Tomography (CBCT) images, which is of great significance for the orthodontic, implant and other dental diagnosis and treatment planning. OBJECTIVES: Currently, tooth root segmentation is mainly done manually because of the similar gray of the tooth root and the alveolar bone from CBCT images. This study aims to explore the automatic tooth root segmentation algorithm of CBCT axial image sequence based on deep learning. METHODS: We proposed a new automatic tooth root segmentation method based on the deep learning U-net with AGs. Since CBCT sequence has a strong correlation between adjacent slices, a Recurrent neural network (RNN) was applied to extract the intra-slice and inter-slice contexts. To develop and test this new method for automatic segmentation of tooth roots using CBCT images, 24 sets of CBCT sequences containing 1160 images and 5 sets of CBCT sequences containing 361 images were used to train and test the network, respectively. RESULTS: Applying to the testing dataset, the segmentation accuracy measured by the intersection over union (IOU), dice similarity coefficient (DICE), average precision rate (APR), average recall rate (ARR), and average symmetrical surface distance (ASSD) are 0.914, 0.955, 95.8% , 95.3% , 0.145 mm, respectively. CONCLUSIONS: The study demonstrates that the new method combining attention U-net with RNN yields the promising results of automatic tooth roots segmentation, which has potential to help improve the segmentation efficiency and accuracy in future clinical practice.

2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Kyungmin Lee ◽  
Gyu-Hyoung Lee

Abstract Background Radiographs are integral in evaluating implant space and inter-root distance. The purpose of this report is to introduce a method for evaluating the 3D root position with minimal radiation using a 3D tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. Materials and methods Intraoral scan and CBCT scan of the patient were obtained before treatment. In the CBCT image, tooth segmentation was performed by isolating individual teeth from the maxillary and mandibular alveolar bone using software program. The 3D tooth model was fabricated by combining segmented individual teeth with the intraoral scan. Results A post-treatment intraoral scan was integrated into the tooth model, and the resulting position of the root could be predicted without additional radiographs. It is possible to monitor the root position after a pretreatment CBCT scan using a 3D tooth model without additional radiographs. Conclusion The application of the 3D tooth model benefits the patient by reducing repeated radiation exposure while providing the clinician with a precise treatment evaluation to monitor tooth movement.


Author(s):  
Marcin Stasiak ◽  
Anna Wojtaszek-Słomińska ◽  
Bogna Racka-Pilszak

Abstract Purpose The aims of this retrospective cross-sectional study were to measure and compare labial and palatal alveolar bone heights of maxillary central incisors in unilateral cleft lip and palate patients, following STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines. Patients and methods The study group consisted of 21 patients with a mean age of 16 years. High-resolution cone-beam computed tomography was performed at least one year after secondary alveolar bone grafting. The experimental side was the cleft side and the contralateral side without congenital cleft was the control. Measurements were performed on incisors’ midsagittal cross-sections. The Wilcoxon signed-rank test was used for intergroup comparisons. Results The labial and palatal distances between alveolar bone crests and cementoenamel junctions were significantly greater on the cleft side than on the noncleft side. Mean differences were 0.75 and 1.41 mm, respectively. The prevalence of dehiscences at the cleft side maxillary central incisors was 52% on the labial surface and 43% on the palatal surface. In the controls, it was 19% and 14%, respectively. Conclusion The cleft-adjacent maxillary central incisors had more apically displaced alveolar bone crests on the labial and palatal sides of the roots than the controls. Higher prevalence of dehiscences was found on the cleft side. Bone margin differences predispose to gingival height differences of the central incisors. These differences could increase the demands of patients to obtain more esthetic treatment results with orthodontic extrusion and periodontal intervention on the cleft side.


2021 ◽  
pp. 103786
Author(s):  
Pieter-Jan Verhelst ◽  
Andreas Smolders ◽  
Thomas Beznik ◽  
Jeroen Meewis ◽  
Arne Vandemeulebroucke ◽  
...  

2021 ◽  
Vol 12 (3) ◽  
pp. 230-233
Author(s):  
Piyush Gupta ◽  
Nivedita Sahoo ◽  
Kavuda Nagarjuna Prasad ◽  
MS Rami Reddy ◽  
Saranya Sreedhar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document