scholarly journals Alternative site testing

2020 ◽  
Author(s):  
1993 ◽  
Vol 39 (2) ◽  
pp. 271-277 ◽  
Author(s):  
G R Warnick ◽  
G J Boerma ◽  
G Assmann ◽  
A T Endler ◽  
G Gerique ◽  
...  

Abstract The Reflotron HDL Cholesterol test (Boehringer Mannheim GmbH) directly separates and analyzes high-density lipoprotein (HDL) cholesterol in plasma collected with EDTA in an integrated dry-reagent system suitable for alternative site testing of lipoproteins. We describe a multicenter evaluation of this test by two US and six European laboratories experienced in lipid analysis. Each laboratory compared the Reflotron with the same conventional wet-chemistry method, Boehringer phosphotungstate-Mg2+ precipitation with enzymatic cholesterol assay. Imprecision was within accepted guidelines, with CVs of < or = 8% for fresh and frozen plasmas (median CV 1.7-3.9%) and for lyophilized sera (median CV 3.8-4.7%), similar to those of the conventional method. Results of linear-regression analysis were as follows: Reflotron HDL Cholesterol = 1.03 conventional - 3.9 mg/L, r = 0.987. The Reflotron results were somewhat low in the two US laboratories, demonstrating the need for general standardization of methods for measuring HDL cholesterol. Results from capillary fingerstick plasma agreed well with those from venous-derived plasma; capillary = 1.04 venous + 4.5 mg/L, r = 0.967. The system is relatively insensitive to interference from hemoglobin (< or = 0.75 g/L), ascorbic acid (< or = 0.3 g/L), bilirubin (< or = 50 mg/L), cholesterol (< or = 3.5 g/L), and triglycerides (< or = 4 g/L). The relative ease of operation and the rapid availability of results (within 90 s for plasma collected in EDTA) make the method appropriate for use by well-trained, but not necessarily technical, operators in the physician's office or other alternative sites.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2499
Author(s):  
Michael Dillon ◽  
Maja A. Zaczek-Moczydlowska ◽  
Christine Edwards ◽  
Andrew D. Turner ◽  
Peter I. Miller ◽  
...  

In the past twenty years marine biotoxin analysis in routine regulatory monitoring has advanced significantly in Europe (EU) and other regions from the use of the mouse bioassay (MBA) towards the high-end analytical techniques such as high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS). Previously, acceptance of these advanced methods, in progressing away from the MBA, was hindered by a lack of commercial certified analytical standards for method development and validation. This has now been addressed whereby the availability of a wide range of analytical standards from several companies in the EU, North America and Asia has enhanced the development and validation of methods to the required regulatory standards. However, the cost of the high-end analytical equipment, lengthy procedures and the need for qualified personnel to perform analysis can still be a challenge for routine monitoring laboratories. In developing regions, aquaculture production is increasing and alternative inexpensive Sensitive, Measurable, Accurate and Real-Time (SMART) rapid point-of-site testing (POST) methods suitable for novice end users that can be validated and internationally accepted remain an objective for both regulators and the industry. The range of commercial testing kits on the market for marine toxin analysis remains limited and even more so those meeting the requirements for use in regulatory control. Individual assays include enzyme-linked immunosorbent assays (ELISA) and lateral flow membrane-based immunoassays (LFIA) for EU-regulated toxins, such as okadaic acid (OA) and dinophysistoxins (DTXs), saxitoxin (STX) and its analogues and domoic acid (DA) in the form of three separate tests offering varying costs and benefits for the industry. It can be observed from the literature that not only are developments and improvements ongoing for these assays, but there are also novel assays being developed using upcoming state-of-the-art biosensor technology. This review focuses on both currently available methods and recent advances in innovative methods for marine biotoxin testing and the end-user practicalities that need to be observed. Furthermore, it highlights trends that are influencing assay developments such as multiplexing capabilities and rapid POST, indicating potential detection methods that will shape the future market.


Sign in / Sign up

Export Citation Format

Share Document