scholarly journals Research of decentralized loop automation simulation in distribution network using MALAB/SIMULINK

Author(s):  
Tuyen Thi Bich Nguyen ◽  
Minh Thi Tinh Le ◽  
Dat Tien Huynh

Nowadays, technologies are rapidly developing, automation is omnipresent in our life. In the power system, automation technology solutions have been applied gradually and widely to meet the requirements of reliability. Before, when a fault occurs on the distribution network, the fault locating, isolating and grid restoring are still being done manually, so a large number of customers that are not in the fault zone still suffer outage for a long time. Distribution Automation System was developed to solve this problem. Currently, with the development of information technology, the Decentralized Loop Automation (DLA) in the distribution network is carried out by communication between the protective devices in the grid. Communication between devices can be done using time-control rules, using GOOSE messages, wifi or according to protocol IEC 61850. In addition, the protective devices can be connected to the control center to create a Centralized Loop Automation (CLA) in the distribution network. The paper considers the DLA solution with the time-control rules for a simple grid. Time-control rules models and simulation results were performed on MATLAB/ SIMULINK software. The paper proposed a user interface for DLA solution with many different failure cases, especially considering the protection coordination in case of doubles failure. The results of the paper show that DLA can isolate faults automatically and restore the grid in a short time, and these results can be developed as an experimental simulation in the future.

2014 ◽  
Vol 971-973 ◽  
pp. 1431-1434
Author(s):  
Yan Hong Li ◽  
Zhi Rong Zhang

Whena fault of the distribution network has occurred, it is necessary to pinpointthe type of the fault and its location and to isolation the fault by sectionswitches. It is then the task toattempts to restore service to as many unfaulted sections of the feeder aspossible via the available sources. Torestore feeder sections, the feeder must be bothering least one backup sourcewith sufficient capacity to bear the additional load. A method based on the backup feeder loadbalancing is proposed and software is developed. The service restores software obtains thedistribution operation data from distribution automation system (SCADA) and thefeeder parameters from power grid production management system (GPMS). Then compares that loads with the sparecapacity for backup sources and bring out the service restoration plan for thedispatch staff.


2015 ◽  
Vol 734 ◽  
pp. 491-494
Author(s):  
Jun Feng Wang

The purpose of this paper is to propose a mixed integer programming model of service restoration reconfiguration considering the minimum switching frequency and power losses. The recovery after the service failure of distribution network is a multi-objective optimization problem with constraints. This paper also discusses the reconfiguration algorithms for power restoration and load balancing in the real-time operation environment of distribution network, which can make the problem solving easy to handle and control. The methods and measures for service auto restoration in distribution automation system are analyzed by examples.


2013 ◽  
Vol 340 ◽  
pp. 1034-1038
Author(s):  
Yang Jia ◽  
Qiang Fu ◽  
Du Shi Ma ◽  
Ming Yang Zhu

Not only distribution automation system but the principle of the existing means of communication are studied systematically and distribution automation communication system model based on IP network is provided. Backbone network is set between master station in the control center and substation sub-station. Communication between electronic station and terminal connections rely on the branch network. Simulation experiment shows the test of data traffic and network delay of IP communications network. In the actual network environment the data refresh meet the application requirements. So the program on the improvement of distribution automation communication in this article is feasible.


2021 ◽  
Vol 2121 (1) ◽  
pp. 012027
Author(s):  
Yinghua Song ◽  
Gang Wang

Abstract On the basis of analyzing and summarizing the current situation of the construction and use of distribution automation systems at home and abroad, according to the requirements of the use of distribution automation systems, a data two-way interactive distribution automation system architecture design is proposed. In response to the requirements for multi-source data collection in the distribution network, a distribution automation system architecture with partitioned collection and bidirectional data flow is proposed to improve the perception of distribution network equipment. Propose the self-recognition technology of power distribution system and terminal based on IEC61968 and IEC61850 model mapping to realize the fast access of power distribution terminal. Propose a grid integration modeling and global decision analysis method based on model splicing technology to realize multi-dimensional data fusion and analysis applications.


2012 ◽  
Vol 241-244 ◽  
pp. 1942-1946
Author(s):  
Zhi Hong Liu ◽  
Jian Wei Zhang ◽  
Xiang Zhao ◽  
Fang Yang

According to the statistic of the distribution network operation, distribution network fault is generally located on line branch, rather than the main line. In view of the structure and characteristics of the current distribution automation system, combining the distribution network reformation and construction practice, this paper puts a comprehensive distribution automation solution that the branch line is equipped with distribution automation terminal which integrates protection and reactive power compensation function. It can achieve the rapid isolation of the distribution network failures and the power supply reliability, and dynamically improve the quality of power supply.


2021 ◽  
Vol 2108 (1) ◽  
pp. 012019
Author(s):  
Zhihao Zhang ◽  
Yulin Qian ◽  
Diandian Zhou ◽  
Kexin Zhang

Abstract People’s lives are becoming more and more inseparable from electricity, and the requirements for the quality of power supply are getting higher and higher. Because of most of the faults in the power system originate from the distribution network, the need to standardize the management of power outages and improve the efficiency of research and judgment has become more and more significant. However, in China, the differences in the development of automation construction in various places and the outage information of different departments require that power outage business applications should try to achieve accurate analysis of outage information under different scenarios. This paper designs a power outage analysis approach, which comprehensively analyzes distribution network data such as substations, lines, and meters, and establishes a signal credibility image, which flexibly mines and analyzes outage events from multiple dimensions and effectively improves the fault tolerance of fault location.