scholarly journals Effects of COVID-19 Infection on P-Wave Dispersion, P-Wave Peak Time and Atrial Conduction Times

2021 ◽  
Vol 9 (3) ◽  
pp. 143-149
Author(s):  
Bedrettin Boyraz ◽  
Ersin İbişoğlu
Author(s):  
Ashish Kumar Agarwal ◽  
Daulat Singh Meena ◽  
Vijay Pathak ◽  
Anoop Jain ◽  
Rakesh Kumar Ola

Background: The aim of the present study was to study the effect of percutaneous balloon mitral  valvuloplasty (PBMV) on P wave dispersion and to test the correlation between P-maximum and  P-dispersion to right ventricular function and pulmonary artery pressure before and after PMBV. Also to study the impact of P-maximum and P-wave dispersion on the short term clinical outcome after successful PBMV in patients with mitral stenosis (MS) and sinus rhythm. Methods: 75 patients undergoing PMBV were enrolled in this study. We evaluated P-maximum, P-minimum and P-wave dispersion before and one month and one year after PBMV . We studied the changes in pulmonary arterial pressure (PAP), left atrial (LA) dimension, mitral diastolic gradient, and mitral valve area, in addition to the changes in right ventricular function utilizing tissue Doppler assessment both before and after PMBV, in addition the role of the P-wave dispersion in prediction of late cardiac events. Results: There were significant decrease in mean diastolic gradient, PAP, and LA size and significant improvement in right ventricular tissue Doppler indices after PMBV. Accompany these hemodynamic changes after PMBV. P-maximum and P-wave dispersion were found to be decreased (P < 0.001). Conclusion: Successful PBMV was associated with a decrease in Pmax and PWD. These simple electrocardiographic indices may predict the success of the procedure immediately after PBMV.  The P-maximum and P-wave dispersion changes were correlated with significant impairment of right dysfunction and the degree of pulmonary artery pressure. Keywords: PBMV.PAP,LA


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
S Masood ◽  
M.M Azharuddin ◽  
S.M.K Ashraf ◽  
S Wahab

Abstract Introduction Around 25% of all ischaemic strokes have no known cause despite standard investigations. Most of these cases are suspected to have an embolic source for ischaemia, leading to the moniker of Embolic Stroke of Undetermined Source (ESUS). Recent studies suggest that abnormalities of the left atrium, in the form of atrial cardiopathy, can lead to increased risk of stroke even in the absence of atrial fibrillation (AF), which may be either as precursors to AF or as independent risk factors for the development of left atrial thrombus and subsequent stroke. Purpose The aim of this study was to measure LA electromechanical dissociation, LA volumes and P-wave dispersion as markers of atrial cardiopathy in patients with ESUS to determine whether atrial cardiopathy may be in the causal pathway of ESUS. Methods 28 patients presenting with ischaemic stroke and fulfilling the criteria for ESUS were enrolled into this cross-sectional, observational study. All patients had 24-hour Holter monitoring done to rule out the presence of AF. The control group consisted of 28 age- and gender-matched apparently healthy individuals. On ECG, P-wave Dispersion (PWD) was calculated by subtracting minimum P-wave duration from maximum P-wave duration. On echocardiography, time intervals from the beginning of P-wave to beginning of A' wave from the lateral mitral annulus in tissue doppler imaging was measured as the atrial electromechanical delay. LA volumes were recorded using the Modified Biplane Simpson's method. Statistical analysis was performed using student's t-test, chi-square test, and Pearson's test. Results Baseline demographic and laboratory characteristics were similar between the two groups. Increased PWD (34.14±9.89 ms vs. 27.32±8.95 ms; p=0.01), atrial electromechanical delay (73.32±16.31 ms vs. 63.63±13.59 ms; p=0.02) and LA volumes were observed in patients with ESUS as compared to controls. A significant correlation was also found between these parameters (p&lt;0.01). Discussion According to the results of our study, PWD, atrial electromechanical delay and LA volumes may be novel predictors for ESUS. Atrial cardiopathy is a unique mechanism of thrombo-embolism in ESUS patients and our data establishes its association with ESUS. Further studies will be needed to shed more light on its role in the causality of stroke in the ESUS population. Measurement of electromechanical delay Funding Acknowledgement Type of funding source: None


2000 ◽  
Vol 23 (11P2) ◽  
pp. 1859-1862 ◽  
Author(s):  
NECLA ÖZER ◽  
KUDRET AYTEMIR ◽  
ENVER ATALAR ◽  
ELIF SADE ◽  
SERDAR AKSÖYEK ◽  
...  

Author(s):  
Raimundo Carmona Puerta ◽  
Elizabeth Lorenzo Martínez ◽  
Magda Alina Rabassa López-Calleja ◽  
Gustavo Padrón Peña ◽  
Juan Miguel Cruz Elizundia ◽  
...  

2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
I Jafaripour ◽  
Z Aryanian ◽  
S Hosseinzadeh ◽  
R Pourkia ◽  
MM Ansari Ramandi ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Lichen planus (LP) which is a chronic inflammatory disease can cause impaired atrial electromechanical coupling, leading to increased risk of atrial fibrillation. Purpose The present study aimed to evaluate atrial electromechanical coupling in LP patients by using electrocardiography (ECG) and echocardiography. Methods Forty-six LP patients were investigated in this cross-sectional case-control study. The control group comprised healthy individuals selected in age and gender-matched manner. Echocardiography and ECG were done for all patients to show inter and intra-atrial electromechanical delays and P wave dispersion respectively. The electromechanical delays were calculated by using the difference between the delays from the onset of the P wave on ECG to the onset of A wave on tissue Doppler recordings of the different areas. Results The baseline characteristics of the case and control group were similar and did not differ significantly. The P wave dispersion was 45.63 ± 3.48 milliseconds in the LP group in comparison to 36.56 ± 2.87 milliseconds in the control group (p &lt; 0.001). As shown in the table, the intra and inter-atrial electromechanical delays were also significantly prolonged in LP patients when compared to the control group (p &lt; 0.001). There was no significant difference between the left and right ventricular systolic function and diastolic function of the two groups. Conclusion The results of the study indicate the presence of significant impaired atrial electromechanical coupling in patients with LP confirmed by both electrocardiographic and echocardiographic tools. Electromechanical delays Case N = 46 (mean ± SD) Control N = 46 (mean ± SD) P value Septal - PA (msec) 59.71 ± 13.24 44.39 ± 11.07 0.002 Lateral - PA (msec) 55.71 ± 13.26 48.89 ± 11.21 0.009 Tricuspid - PA (msec) 52.37 ± 13.12 43.28 ± 10.58 0.002 Inter-atrial delay (msec) (lateral PA−RV PA) 8.47 ± 1.62 6.37 ± 1.36 &lt;0.001 Intra-atrial delay (msec) (LA) [lateral PA−septal PA] 4.80 ± 1.48 3.83 ± 0.82 &lt;0.001 Intra-atrial delay (msec) (RA) [septal PA−RV PA] 3.91 ± 0.96 2.02 ± 0.71 &lt;0.001 PA Delay from the onset of the P wave on ECG to the onset of A wave on tissue Doppler, N: number, SD: Standard Deviation, LA: Left Atrium, RA: Right Atrium, RV: Right Ventricle


Sign in / Sign up

Export Citation Format

Share Document