scholarly journals Valgus Osteotomy Outcome for Treating Femoral Neck Nonunion in Young and Active Patients

2021 ◽  
Vol 8 (2) ◽  
pp. 65-70
Author(s):  
Kaveh Gharanizadeh ◽  
◽  
Hamed Tayyebi ◽  
Abbas Esmaeli ◽  
Maziar Rajei ◽  
...  

Background: Femoral neck fracture nonunion is a frequent and challenging complication, with several surgical options. Objectives: The present study reported the outcome of valgus osteotomy for treating femoral neck nonunion in patients aged <65 years. Methods: This case series research included young patients who underwent valgus osteotomy for treating femoral neck nonunion or device failure of the index surgery. The fixation of the osteotomy site was performed using either a dynamic hip screw or a fixed angle blade. The union of the neck and osteotomy site (subtrochanteric region) was evaluated by monitoring callus formation in the postoperative radiographs. Limb length discrepancy, Pauwels’ angle, and the neck-shaft angle were evaluated before the surgery and at the last follow-up. Postoperative complications were extracted from the explored patients’ profiles. Results: Twenty patients with a Mean±SD age of 27.2±10.8 years were examined in this study‎. The Mean±SD follow-up time of the patients was 6.1±3.9 years. The femoral neck was united in 18 patients in a Mean±SD period of 5.1±2.3 months. The Mean±SD limb length discrepancy was measured as 1.3±0.8 cm before and 0.5±0.7 cm after the ‏osteotomy. The Mean±SD Pauwels’ angle was calculated as 65.5±16.9º before and 32.4±16.2º after the osteotomy. The Mean±SD neck-shaft angle was computed to be 121.9±22.8º before and 144.5±17.7º after the osteotomy. Revision surgery was performed for 6 (30%) patients. This measure included device removal in 4 and total hip arthroplasty in 2 patient. Conclusion: Valgus osteotomy is a safe and efficient technique for managing femoral neck nonunion. Therefore‎, this approach is suggested as a good alternative for total hip arthroplasty, particularly in young and active patients‎.

2019 ◽  
Vol 27 (2) ◽  
pp. 230949901985803
Author(s):  
Goksel Dikmen ◽  
Vahit Emre Ozden ◽  
Fırat Gulagaci ◽  
I. Remzi Tozun

Purpose: The purpose of this study was to report the long-term results of total hip arthroplasty (THA) for the treatment of ankylosed hip. Methods: Twenty-nine consecutive THAs were performed in 26 patients. The mean age of the patients at the time of the operation was 43.3 years (range, 19–69 years). We used cementless fixation in all hips and the mean duration of follow-up was 10.1 years (range, 4.5–20 years). Radiological evaluation of components, osteolysis, radiolucent lines and loosening were assessed. The Harris Hip Score (HHS), range of motion (ROM), limb-length discrepancy and walking capacity with or without any support were used preoperatively and at final follow-up for clinical evaluation. Survivorship analysis was conducted using the Kaplan–Meier method using second revision for any reason as the endpoint. Results: The mean HHS was 85.6 (range, 55–98) points and mean ROM was 110.5° for flexion. The mean limb-length discrepancy improved from 4.1 cm to 1.1 cm. Positive Trendelenburg sign was recorded in 31% of the patients and 24% of patients needed any support for walking postoperatively. We observed surgical complications related to abductor arm in 25% of the patients. Radiolucency on the acetabular side was seen on one or more zones in 15 patients (16 hips). One aseptic acetabular component loosening was observed. On the femoral side, 11 patients demonstrated non-progressive radiolucent lines and osteolysis around the stem was seen in four hips but there was no aseptic stem loosening. The Kaplan–Meier survival rate considering revision for any reason as the endpoint was 81.5%, for aseptic loosening 91.3%, for a worst-case scenario of 66.4% at 10 years. Conclusion: Cementless fixation showed good to excellent results at 10 years. Preoperative and postoperative abductor status of the patient is critical for patient satisfaction.


Medicina ◽  
2013 ◽  
Vol 49 (3) ◽  
pp. 22
Author(s):  
Jaunius Kurtinaitis ◽  
Narūnas Porvaneckas ◽  
Giedrius Kvederas ◽  
Tomas Butėnas ◽  
Valentinas Uvarovas

Background and Objective. Intracapsular fractures of the femoral neck account for a major share of fractures in the elderly. Open reduction and internal fixation has been shown to have a higher rate of revision surgery than arthroplasty. The aim of this study was to assess and compare the rates of revision surgery performed after internal fixation and primary total hip arthroplasty. Material and Methods. Between 2004 and 2006, 681 intracapsular femoral neck fractures in 679 consecutive patients were treated with internal fixation or total hip arthroplasty at our institution. Revision surgery rates were evaluated at 1-, 3-, 6-, 12-, and 24-month follow-up. Results. There was no significant difference in the ratio of internal fixation to total hip arthroplasty during 2004–2006 (P=0.31). The mean rate of total hip arthroplasty was 19.1% with a lower rate being among patients younger than 60 years. Revision surgery rates at the 2-year followup were higher in the internal fixation group compared with total hip arthroplasty group (28.9% vs. 7.0%, P<0.001). Patients who underwent internal fixation were at a 4-fold greater risk of having revision surgery at the 2-year follow-up than those who underwent total hip arthroplasty (odds ratio, 4.11; 95% CI, 1.95–8.65; P<0.001). Age was a significant risk factor for revision surgery after total hip arthroplasty (hazard ratio, 0.93; 95% CI, 0.87–0.98; P=0.02), but not significant after the internal fixation (P=0.86). Conclusions. Higher revision surgery rates after internal fixation favors arthroplasty as a primary choice of treatment for the femoral neck fractures.


2022 ◽  
Vol 11 (2) ◽  
pp. 346
Author(s):  
Ali Darwich ◽  
Kim Pankert ◽  
Andreas Ottersbach ◽  
Marcel Betsch ◽  
Sascha Gravius ◽  
...  

The aim of this study was to investigate the radiological and clinical outcome of the direct anterior approach (DAA) in total hip arthroplasty (THA) using a collared cementless femoral short-stem. This retrospective study included 124 patients with 135 THAs operated from 2014 to 2016 using a collared cementless triple tapered hydroxyapatite-coated femoral short-stem (AMIStem H Collared®, Medacta International, Castel San Pietro, Switzerland) implanted with a DAA. Follow-up was performed at three months, 12 months, and five years. Clinical outcome was assessed using the hip osteoarthritis outcome score (HOOS) and radiological analysis was done using conventional radiographs, which included evaluation of the femur morphology based on Dorr classification, of radiolucencies based on the Gruen zone classification and of stem subsidence. The mean age was 67.7 ± 11.3 years and the mean body mass index (BMI) was 27.4 ± 4.4 kg/m2. The stem survival rate at five years was 99.1% with one revision due to recurrent dislocations. Mean HOOS score improved from 40.9 ± 18.3 preoperatively to 81.5 ± 19.7 at three months, 89.3 ± 10.9 at 12 months, and 89.0 ± 14.0 at five years (all with p < 0.001). No significant correlations were found between age, femoral bone morphology, BMI and HOOS, and the appearance of relevant radiolucencies.


2020 ◽  
Vol 102-B (11) ◽  
pp. 1491-1496
Author(s):  
Pranai K. Buddhdev ◽  
Ivor S. Vanhegan ◽  
Tahir Khan ◽  
Aresh Hashemi-Nejad

Aims Despite advances in the treatment of paediatric hip disease, adolescent and young adult patients can develop early onset end-stage osteoarthritis. The aims of this study were to address the indications and medium-term outcomes for total hip arthroplasty (THA) with ceramic bearings for teenage patients. Methods Surgery was performed by a single surgeon working in the paediatric orthopaedic unit of a tertiary referral hospital. Databases were interrogated from 2003 to 2017 for all teenage patients undergoing THA with a minimum 2.3 year follow-up. Data capture included patient demographics, the underlying hip pathology, number of previous surgeries, and THA prostheses used. Institutional ethical approval was granted to contact patients for prospective clinical outcomes and obtain up-to-date radiographs. In total, 60 primary hips were implanted in 51 patients (35 female, 16 male) with nine bilateral cases. The mean age was 16.7 years (12 to 19) and mean follow-up was 9.3 years (2.3 to 16.8). Results The most common indication for teenage hip arthroplasty was avascular necrosis secondary to slipped upper femoral epiphysis (31%; n = 16). Overall, 64% of patients (n = 33) had undergone multiple previous operations. The survival at follow-up was 97%; two patients required revision for aseptic loosening (one femoral stem, one acetabular component). Both patients had fused hips noted at the time of arthroplasty. A further two patients had radiolucent lines but were asymptomatic. At latest follow-up the mean Oxford Hip Score was 44 (31 to 48) and a Visual Analogue Scale measurement of 1.5, indicating satisfactory function. Conclusion Operating on this cohort can be complicated by multiple previous surgeries and distorted anatomy, which in some cases require custom-made prostheses. We have demonstrated a good outcome with low revision rate in this complex group of patients. Cite this article: Bone Joint J 2020;102-B(11):1491–1496.


2018 ◽  
Vol 29 (6) ◽  
pp. 603-608 ◽  
Author(s):  
Yingyong Suksathien ◽  
Jithayut Sueajui

Purpose: To evaluate the clinical and radiographic mid-term results of short-stem total hip arthroplasty (THA) in patients with osteonecrosis of the femoral head (ONFH). Methods: We reviewed 83 cases that underwent Metha stem between November 2010 and November 2012. The appearance of bone trabeculae development and radiolucent line were reviewed and HHS was recorded at 6 months postoperatively then yearly to evaluate the clinical results. Results: The mean age of patients was 43.8 years with the mean follow-up 69.3 (60–84) months. Harris Hip Score improved significantly from 44.7 preoperatively to 99.6 at the last follow-up ( p < 0.0001). There were 4 cases (4.8%) of intraoperative femoral fractures. There was 1 case (1.2%) of distal stem perforation that had stable bone ingrowth and there was 1 case (1.2%) of 5-mm subsidence, which was then stable at 3 months postoperatively. Bone trabecular development was detected at zone 1 (65.1%), 2 (69.9%), 3 (14.4%), 4 (1.2%), 6 (97.6%) and 7 (81.9%). There was 1 case (1.2%) where radiolucent lines were observed in zones 1 and 7. There was 1 femoral stem revision from periprosthetic fracture 4 years after index surgery and 1 cup revision from aseptic loosening. Kaplan-Meier survivorship with the end point of stem revision for any reason was 98.8% and for aseptic loosening it was 100% at 7 years. Conclusions: The mid-term clinical and radiographic results of the Metha stem in patients with ONFH were promising. Its design enables preservation of the bone stock and the bone trabeculae appear to confirm the assumption of proximal force transmission.


2020 ◽  
pp. 112070002092665
Author(s):  
Syed H Mufarrih ◽  
Nada Q Qureshi ◽  
Bassam Masri ◽  
Shahryar Noordin

Objectives: Femoral neck fractures (FNFs), with up to 15% mortality, are prominent orthopaedic emergencies. After treating FNFs, dislocation is another challenge increasing morbidity, mortality and treatment costs substantially. The emerging dual-mobility cup (DMC) may decrease dislocation rates following total hip arthroplasty (THA) for FNFs. We performed a systematic review of literature reporting dislocation and mortality rates with DMC-THA for the treatment of FNFs. Methods: 2 authors independently searched PubMed (MEDLINE), Google Scholar and Cochrane library for studies reporting dislocation and mortality rates for FNFs treated with DMC-THA since inception up to January 2019. Data on outcomes of interest was extracted from all studies and assessed for eligibility for a meta-analysis. Results: Out of 522 search results, 18 studies were included in the systematic review and 4 in the meta-analysis. The mean rate of dislocation following DMC-THA for FNFs was found to be 1.87% ± 2.11, with a 1-year mortality rate of 14.0% ± 10.55. Results of meta-analysis showed that dislocation and 1-year postoperative mortality rates were significantly lower for DMC-THA with a risk ratio 0.31 (95% CI, 0.16–0.59; I2 = 0%, p  = 0.0003) and 0.55 (0.40, 0.77; I2 = 0%, p = 0.003) respectively when compared to biploar hemiathroplasty (BHA). Conclusions: The mean dislocation and mortality rates in DMC-THA are lower than previously reported rates for THA with single cup and comparable to unipolar and bipolar hemiarthroplasty. Further research involving randomised control trials to assess differences in outcomes, longevity and cost-effectiveness needs to be conducted to make recommendations for the use of DMC in treating FNFs.


2019 ◽  
Vol 7 (6) ◽  
pp. 232596711985436 ◽  
Author(s):  
Mark R. Nazal ◽  
Ali Parsa ◽  
Scott D. Martin

Background: The use of hip arthroscopic surgery in patients suffering from chronic hip pain after total hip arthroplasty (THA) has a limited presence in the literature, with most studies having limited follow-up. Purpose: The first goal of this study was to evaluate hip arthroscopic surgery in the diagnosis and management of patients with chronic hip pain after THA. The second goal was to describe a new cause of iliopsoas tendinopathy (IPT) involving disruption of the anterior capsule. Study Design: Case series; Level of evidence, 4. Methods: We conducted a retrospective analysis with prospectively collected clinical outcomes of patients after THA who underwent hip arthroscopic surgery for chronic hip pain without an identifiable cause. The patients were at least 18 years old and had a minimum follow-up of 24 months. Results: The retrospective analysis found that hip arthroscopic surgery led to new diagnostic information in 8 patients (80%). Of the 10 patients diagnosed with IPT, 4 (40%) lacked an anatomic cause; however, these patients had a history of difficult exposure of the anterior capsule and/or a lack of capsular repair during index THA. The mean modified Harris Hip Score (mHHS) was 71.9 ± 15.6, and the mean 6-month postoperative visual analog scale (VAS) pain score was 0.8 ± 2.2, which was significantly lower than preoperatively ( P = .0055). There was also significantly improved forward flexion range of motion ( P = .0183) and straight leg raise (SLR) strength test results ( P = .0263). Hip arthroscopic surgery resulted in 8 patients (80%) continuing to be pain-free at a mean follow-up of 6.8 ± 1.4 years, while 2 patients (20%) progressed to revision arthroplasty. There were no major or minor complications. Conclusion: Hip arthroscopic surgery was found to have an important role in the diagnostic and therapeutic management of patients with chronic hip pain after THA, with good clinical outcomes at a mean follow-up of 6.8 years and no complications. We believe that disruption of the anterosuperior acetabular capsule, including the reflected head of the rectus femoris, can allow the iliopsoas tendon to move intra-articularly and precipitate IPT. This disruption may be appreciated on the SLR strength test. Although this study presents a small sample size that cannot substantiate a cause-effect relationship, orthopaedic surgeons performing THA should consider minimizing disruption and/or ensuring repair of the anterior capsule to decrease this potential cause of IPT.


2006 ◽  
Vol 309-311 ◽  
pp. 1357-1362
Author(s):  
Masahiro Hasegawa ◽  
Akihiro Sudo ◽  
Atsumasa Uchida

In ceramic-on-ceramic total hip arthroplasty (THA), modular acetabular component with a sandwich insertion was developed and evaluated mid-term clinical results. 35 hips had undergone cementless ceramic-on-ceramic THA with sandwich cup (Kyocera, Kyoto, Japan). The mean duration of follow-up was 5 years. 6 hips had undergone component revisions. The reasons for revision included infection in 1 hip, dislocation with loosening in 2 hips, alumina liner fractures in 2 hips, and cup dissociation in 1 hip. All femoral and acetabular components showed no loosening in the unrevised hips at the time of the last follow-up. None of the 29 unrevised hips had osteolysis.


2018 ◽  
Vol 29 (1) ◽  
pp. 65-71 ◽  
Author(s):  
Yoshitoshi Higuchi ◽  
Taisuke Seki ◽  
Yukiharu Hasegawa ◽  
Yasuhiko Takegami ◽  
Daigo Morita ◽  
...  

Introduction: This study aimed to compare the clinical and radiographic results of 28-mm ceramic-on-ceramic (CoC) total hip arthroplasty (THA) to those of 32-mm CoC during a 5- to 15-year follow-up period. Methods: 107 joints (95 women and 6 men) underwent 28-mm CoC, and 60 (49 women and 7 men) underwent 32-mm CoC. The average patient age at the time of surgery was 56.1 and 55.7 years in the 28-mm and 32-mm CoC groups, respectively. Clinical and radiologic measurements of all patients were analysed. Results: The mean preoperative Harris hip score (HHS) was similar in the 2 groups (28-mm, 58.9; and 32-mm, 58.5). However, at final follow-up, the mean HHS of the 32-mm CoC (91.8) was significantly better than that of the 28-mm CoC (88.2) ( p = 0.003), as were the ranges of motion (ROM) for flexion (98.3 ± 13.5° vs. 87.3 ± 19.3°, p < 0.001) and abduction (27.8 ± 14.9° vs. 22.1 ± 19.3°, p = 0.007). The mean wear rate was 0.0044 mm/year for the 28-mm CoC and 0.0044 mm/year for the 32-mm CoC. No ceramic fractures were found in the 2 groups. One joint in the 28-mm CoC (0.9%) required revision owing to progressive osteolysis. Kaplan-Meier survival at 10 years, with implant loosening or revision THA as the endpoint, was 98.3% for 28-mm CoC and 100% for 32-mm CoC ( p = 0.465). Conclusion: There was no significant difference in ceramic-related complications between the 2 groups. Our study demonstrated that the 32-mm and 28-mm CoC are safe and are associated with good clinical outcomes.


2020 ◽  
pp. 112070002094140
Author(s):  
Kanai Garala ◽  
Tarek Boutefnouchet ◽  
Rishanthanan Amblawaner ◽  
Trevor Lawrence

Background: Revision total hip arthroplasty (rTHA) is often complex and has a less reliable outcome than primary total hip arthroplasty. Acetabular reconstruction remains a challenge because of the variable amount of bone loss. This study describes and evaluates a novel technique of acetabular reconstruction using composite bone grafting. Patients and methods: Between June 2005 and January 2012, 108 consecutive patients underwent revision hip arthroplasty in which the acetabular component was revised using composite bone grafting. Of these, 24 were lost to follow-up leaving 84 in the study with a minimum 5-year follow-up. There were 54 women and 30 men with a mean age of 70.1 (31–91) years. All patients were assessed clinically and radiologically after a minimum of 5 years. The primary outcome measures were rate of re-revision, patient-reported outcomes and radiological evidence of loosening. Results: The mean follow-up after revision surgery was 6.9 years (5–10). At operation, 60 patients had an acetabular defect of AAOS stage 3 or more. There was no evidence of loosening in 69 revision acetabular components; 12 showed evidence of non-progressive loosening and 3 patients underwent a re-revision procedure (2 for infection, 1 recurrent dislocation). The mean postoperative Hip Disability and Osteoarthritis Outcome Score (HOOS) was 89.11/100 (95% CI, 87.8–90.5). Scores were significantly improved in patients with a more extensive preoperative defect ( p  = 0.006). The overall patient satisfaction rate at final follow-up was very high. Conclusions: Composite impaction grafting using a layered cement and bone graft technique can give satisfactory clinical and radiological outcomes in the medium- to long-term.


Sign in / Sign up

Export Citation Format

Share Document