custom made prostheses
Recently Published Documents


TOTAL DOCUMENTS

23
(FIVE YEARS 9)

H-INDEX

5
(FIVE YEARS 2)

2021 ◽  
Vol 11 (18) ◽  
pp. 8584
Author(s):  
Giuseppe Bianchi ◽  
Tommaso Frisoni ◽  
Benedetta Spazzoli ◽  
Alessandra Lucchese ◽  
Davide Donati

Primary bone sarcomas are rare tumors and surgical resection in combination with chemo and radiation therapy is the mainstay of treatment. Some specific anatomical sites still represent a reconstructive challenge due to their complex three-dimensional anatomy. In recent years, patient specific instruments along with 3D printing technology has come to represent innovative techniques in orthopaedic oncology. We retrospectively reviewed 23 patients affected by primary bone sarcoma treated with patient-specific instruments and 3D printing custom made prostheses. At follow up after approximately two years, the infection rate was 26%, mechanical complication rate 13%, and local recurrence rate 13% (with a five-years implant survival rate of 74%). Based on our experience, patient-specific instruments and 3D custom-made prostheses represents a reliable and safe technique for improving the accuracy of resection of primary bone tumour, with a particular use in pelvic surgery ameliorating functional results.


2021 ◽  
Vol 10 (16) ◽  
pp. 3539
Author(s):  
Carmine Zoccali ◽  
Jacopo Baldi ◽  
Dario Attala ◽  
Alessandra Scotto di Uccio ◽  
Luca Cannavò ◽  
...  

Wide resection is currently considered the mainstay treatment for primary bone tumors. When the tumor is located in anatomically complex segments, 3D-Printed Titanium Custom-Made Prostheses (3DPTCMP) are possible reconstructive solutions. The aim of the present paper is to analyze indications, results and complications of a series of 14 patients who underwent pelvis reconstruction with 3DPTCMP after tumor removal from January 2015 to December 2019. Chondrosarcoma was the main histology; indications were tumors located in the acetabular area without enough residual bone to support a cup with an iliac stem, and tumors located near the sacrum-iliac joint. The margins were wide in 12 cases, and marginal and intralesional in one case each. In three cases, resection also included the sacrum-iliac joint, so a spine stabilization was performed and linked to the pelvic prosthesis; The average MSTS score was 46.3%; the 5-year local recurrence-free survival was 85.7%. Wound dehiscences were the main complication, resolved with multiple debridements; nevertheless, prosthesis removal was necessary in one case. Currently, the 3DPTCMP is an effective resource for reconstruction after resection of tumors located in the pelvis. Further studies are necessary to value long-term results; more strategies are necessary to try to reduce the infection rate and improve osteointegration.


2021 ◽  
Vol 103-B (4) ◽  
pp. 795-803
Author(s):  
Tomohiro Fujiwara ◽  
Manuel Ricardo Medellin Rincon ◽  
Andrea Sambri ◽  
Yusuke Tsuda ◽  
Rhys Clark ◽  
...  

Aims Limb salvage for pelvic sarcomas involving the acetabulum is a major surgical challenge. There remains no consensus about what is the optimum type of reconstruction after resection of the tumour. The aim of this study was to evaluate the surgical outcomes in these patients according to the methods of periacetabular reconstruction. Methods The study involved a consecutive series of 122 patients with a periacetabular bone sarcoma who underwent limb-salvage surgery involving a custom-made prosthesis in 65 (53%), an ice-cream cone prosthesis in 21 (17%), an extracorporeal irradiated autograft in 18 (15%), and nonskeletal reconstruction in 18 (15%). Results The rates of major complications necessitating further surgery were 62%, 24%, 56%, and 17% for custom-made prostheses, ice-cream cone prostheses, irradiated autografts and nonskeletal reconstructions, respectively (p = 0.001). The ten-year cumulative incidence of failure of the reconstruction was 19%, 9%, 33%, and 0%, respectively. The major cause of failure was deep infection (11%), followed by local recurrence (6%). The mean functional Musculoskeletal Tumour Society (MSTS) scores were 59%, 74%, 64%, and 72%, respectively. The scores were significantly lower in patients with major complications than in those without complications (mean 52% (SD 20%) vs 74% (SD 19%); p < 0.001). For periacetabular resections involving the ilium, the mean score was the highest with custom-made prostheses (82% (SD 10%)) in patients without any major complication; however, nonskeletal reconstruction resulted in the highest mean scores (78% (SD 12%)) in patients who had major complications. For periacetabular resections not involving the ilium, significantly higher mean scores were obtained with ice-cream cone prostheses (79% (SD 17%); p = 0.031). Conclusion Functional outcome following periacetabular reconstruction is closely associated with the occurrence of complications requiring further surgery. For tumours treated with periacetabular and iliac resection, skeletal reconstruction may result in the best outcomes in the absence of complications, whereas nonskeletal reconstruction is a reasonable option if the risk of complications is high. For tumours requiring periacetabular resection without the ilium, reconstruction using an ice-cream cone prosthesis supported by antibiotic-laden cement is a reliable option. Cite this article: Bone Joint J 2021;103-B(4):795–803.


2021 ◽  
Vol 12 (2) ◽  
pp. 234-243 ◽  
Author(s):  
Yuki Nakamura ◽  
Charles Romans ◽  
Ravi Ashwath

Background: In pediatric cardiac surgery, an application of three-dimensional (3D) modeling to develop custom-made prostheses is limited, and currently surgeons use their intraoperative visual estimation to develop 3D complex structures from 2D patch materials. Contemporary 3D designers are developing complex surfaces using surface modeling in other industries, which can be applied to pediatric cardiac surgery. However, its free-form nature may lead to intradesigner variability. Methods: A patient with a body weight of 4 kg with partial anomalous pulmonary venous connection and preoperative computed tomography data was selected, and a patient-specific 3D heart model was obtained. Through collaboration with a pediatric cardiologist and a pediatric cardiac surgeon, a 3D designer developed two patient-specific 3D patches for an intra-atrial rerouting procedure (IAR) for the patient using different methods of surface modeling. The shape and size of two flattened patches were analyzed using a geometric morphometrics (GM) approach. Computational fluid dynamics (CFD) analysis was also performed to calculate pressure drop across streamlines and flow energy loss in the right atrium for both patches. Results: The GM analysis showed that the size and shape of the two patches around the systemic vein orifice, crucial to prevent systemic venous obstruction, were almost equivalent. However, the CFD analysis showed that the pressure drop and flow energy loss were almost twice for one patch compared with the other. Conclusions: Our platform of developing a patient-specific 3D patch for an IAR procedure using surface modeling seemed promising, although intradesigner patch variability was not neglectable in our small-sized patient.


2020 ◽  
Vol 9 (11) ◽  
pp. 3546 ◽  
Author(s):  
Joan Ferràs-Tarragó ◽  
Vicente Sanchis-Alfonso ◽  
Cristina Ramírez-Fuentes ◽  
Alejandro Roselló-Añón ◽  
Francisco Baixauli-García

Background: Mirroring the image of the affected side is a widely used technique for surgical planning in orthopedic surgery, especially for fractures and custom-made prostheses. Our objective is to evaluate the three-dimensional symmetry of the femurs using finite element analysis and manual alignment. Methods: Using the computed tomography of 15 patients without lower limb pathology, 30 3D biomodels of their femurs were obtained. The error obtained through image manipulation was calculated and broken down into a rendering error and a manual overlay error. The Hausdorff–Besicovitch method was applied to obtain the total asymmetry. The manipulation error was theb subtracted from it to obtain the intrapersonal asymmetry. Results: The mean intrapersonal asymmetry was 0.93 mm. It was obtained by subtracting the error derived from rendering and alignment of 0.59 mm (SD 0.17 mm) from the overall mean error of 1.52 mm (SD 1.45). Conclusions: Intrapersonal femoral asymmetry is low enough to use the mirror image of the healthy side as a reference for three-dimensional surgical planning. This type of planning is especially useful in deformity surgery when the objective of the surgery is not to restore only one specific parameter but to obtain a general functional morphology when a healthy contralateral femur is available.


2020 ◽  
Vol 102-B (11) ◽  
pp. 1491-1496
Author(s):  
Pranai K. Buddhdev ◽  
Ivor S. Vanhegan ◽  
Tahir Khan ◽  
Aresh Hashemi-Nejad

Aims Despite advances in the treatment of paediatric hip disease, adolescent and young adult patients can develop early onset end-stage osteoarthritis. The aims of this study were to address the indications and medium-term outcomes for total hip arthroplasty (THA) with ceramic bearings for teenage patients. Methods Surgery was performed by a single surgeon working in the paediatric orthopaedic unit of a tertiary referral hospital. Databases were interrogated from 2003 to 2017 for all teenage patients undergoing THA with a minimum 2.3 year follow-up. Data capture included patient demographics, the underlying hip pathology, number of previous surgeries, and THA prostheses used. Institutional ethical approval was granted to contact patients for prospective clinical outcomes and obtain up-to-date radiographs. In total, 60 primary hips were implanted in 51 patients (35 female, 16 male) with nine bilateral cases. The mean age was 16.7 years (12 to 19) and mean follow-up was 9.3 years (2.3 to 16.8). Results The most common indication for teenage hip arthroplasty was avascular necrosis secondary to slipped upper femoral epiphysis (31%; n = 16). Overall, 64% of patients (n = 33) had undergone multiple previous operations. The survival at follow-up was 97%; two patients required revision for aseptic loosening (one femoral stem, one acetabular component). Both patients had fused hips noted at the time of arthroplasty. A further two patients had radiolucent lines but were asymptomatic. At latest follow-up the mean Oxford Hip Score was 44 (31 to 48) and a Visual Analogue Scale measurement of 1.5, indicating satisfactory function. Conclusion Operating on this cohort can be complicated by multiple previous surgeries and distorted anatomy, which in some cases require custom-made prostheses. We have demonstrated a good outcome with low revision rate in this complex group of patients. Cite this article: Bone Joint J 2020;102-B(11):1491–1496.


2020 ◽  
Vol 11 ◽  
pp. 148
Author(s):  
Domenico Policicchio ◽  
Gina Casu ◽  
Giosuè Dipellegrini ◽  
Artan Doda ◽  
Giampiero Muggianu ◽  
...  

Background: The aim of this study was to compare the results of two different titanium cranioplasties for reconstructing skull defects: standard precurved mesh versus custom-made prostheses. Methods: Retrospective analysis of 23 patients submitted to titanium cranioplasty between January 2014 and January 2019. Ten patients underwent delayed cranioplasty using custom-made prostheses; and 13 patients were treated using precurved titanium mesh (ten delayed cranioplasties, and three single-stage resection- reconstructions). Demographic, clinical, and radiological data were recorded. Results and complications of the two methods were compared, including duration of surgery, cosmetic results (visual analog scale for cosmesis [VASC]), and costs of the implants. Results: Complications: one epidural hematoma in the custom-made group, one delayed failure in precurved group due to wound dehiscence with mesh exposure. There were no infections in either group. All custom-made prostheses perfectly fitted on the defect; eight of 13 precurved mesh prostheses incompletely covered the defect. Custom-made cranioplasty obtained better cosmetic results (average VASC 94 vs. 68), shorter surgical time (141min vs. 186min), and -fewer screws was needed to fix the prostheses in place (6 vs. 15). However, satisfactory results were obtained using precurved mesh in cases of small defects and in single-stage reconstruction. Precurved mesh was found to be cheaper (€1,500 vs. €5,500). Conclusion: Custom-made cranioplasty obtained better results and we would suggest that this should be a first choice, particularly for young patients with a large cranial defect. Precurved mesh was cheaper and useful for single-stage resection-reconstruction. Depending on the individual conditions, both prostheses have their place in cranioplasty therapies.


2020 ◽  
Vol 44 (5) ◽  
pp. 829-837 ◽  
Author(s):  
Andrea Angelini ◽  
Daniel Kotrych ◽  
Giulia Trovarelli ◽  
Andrzej Szafrański ◽  
Andrzej Bohatyrewicz ◽  
...  

2019 ◽  
Vol 42 (3) ◽  
pp. 769-775 ◽  
Author(s):  
Federico Bianchi ◽  
Francesco Signorelli ◽  
Rina Di Bonaventura ◽  
Gianluca Trevisi ◽  
Angelo Pompucci

2018 ◽  
Vol 100-B (1_Supple_A) ◽  
pp. 22-30 ◽  
Author(s):  
T. S. Brown ◽  
C. G. Salib ◽  
P. S. Rose ◽  
F. H. Sim ◽  
D. G. Lewallen ◽  
...  

AimsReconstruction of the acetabulum after resection of a periacetabular malignancy is technically challenging and many different techniques have been used with varying success. Our aim was to prepare a systematic review of the literature dealing with these techniques in order to clarify the management, the rate of complications and the outcomes.Patients and MethodsA search of PubMed and MEDLINE was conducted for English language articles published between January 1990 and February 2017 with combinations of key search terms to identify studies dealing with periacetabular resection with reconstruction in patients with a malignancy. Studies in English that reported radiographic or clinical outcomes were included. Data collected from each study included: the number and type of reconstructions, the pathological diagnosis of the lesions, the mean age and follow-up, gender distribution, implant survivorship, complications, functional outcome, and mortality. The results from individual studies were combined for the general analysis, and then grouped according to the type of reconstruction.ResultsA total of 57 studies met the inclusion criteria and included 1700 patients. Most lesions were metastatic (41%), followed by chondrosarcoma (29%), osteosarcoma (10%), Ewing’s sarcoma (7%), and multiple myeloma (2%). The techniques of reconstruction were divided into seven types for analysis: those involving a Harrington reconstruction, a saddle prosthesis, an allograft and allograft prosthesis composite, a pasteurised autograft, a porous tantalum implant, a custom-made prosthesis and a modular hemipelvic reconstruction. The rate of complications was 50%, with infection (14%) and instability (8%) being the most common. Mortality data were available for 1427 patients (84%); 50% had died of disease progression, 23% were alive with disease, and 27% had no evidence of disease at a mean follow-up of 3.4 years (0 to 34).ConclusionBoth the rate of complications and mortality are high following resection of oncological periacetabular lesions and reconstruction. Many types of reconstruction have been used with unique challenges and complications for each technique. Newer prostheses, including custom-made prostheses and porous tantalum implants and augments, have shown promising early functional and radiographic outcomes. Cite this article: Bone Joint J 2018;100-B(1 Supple A):22–30.


Sign in / Sign up

Export Citation Format

Share Document