scholarly journals Design of Porous Metal Block Augmentation to Treat Tibial Bone Defects in Total Knee Arthroplasty Based on Topology Optimization

Author(s):  
Yang Liu ◽  
Bingpeng Chen ◽  
Chenyu Wang ◽  
Hao Chen ◽  
Aobo Zhang ◽  
...  

Metal block augmentation, which is used for the treatment of tibial bone defects in total knee arthroplasty, with high stiffness will cause significant alteration in stress distribution, and its solid structure is not suitable for osseointegration. This study aimed to design a porous block to reduce weight, promote bone ingrowth, and improve its biomechanical performance. The metal block augmentation technique was applied to finite element models of tibial bone defects. Minimum compliance topology optimization subject to volume fraction combined with the porous architecture was adopted to redesign the block. Biomechanical changes compared with the original block were analyzed by finite element analysis. The stress distribution of the block and proximal tibia was recorded. The strain energy density of the proximal tibia was obtained. The newly designed block realized 40% weight reduction. The maximum stress in the optimized block decreased by 11.6% when compared with the solid one. The maximum stress of the proximal tibia in the optimized group increased by 18.6%. The stress of the anterior, medial, and posterior parts of the proximal medial tibia in the optimized group was significantly greater than that in the original group (all p < 0.05). The optimized block could effectively improve the biomechanical performance between the block and the bone. The presented method might provide a reference for the design of customized three-dimensional printed prostheses.

2018 ◽  
Vol 225 ◽  
pp. 03009 ◽  
Author(s):  
N.M.A. Azam ◽  
Rosdi Daud ◽  
H. Mas Ayu ◽  
J. Ramli ◽  
M.F.B. Hassan ◽  
...  

The effect of flexion angle on contact stress of the knee joint still open to the debate since lack of proof shown that flexion angles does effect the contact stress of Total Knee Arthroplasty (TKA). Thus the aim of this study is to investigate the effect of different flexion angle on contact stress of TKA via finite element method. The TKA is simulated using ANSYS Workbench and the applied loads are 2200 N, 3200 N and 2800 N. The Finite element Analysis (FEA) results for maximum stress of current and proposed designed were then compared. For the new proposed design, the maximum stress for 15° is 12.2 MPa, 45° is 23.6 MPa and 60° is 22.5 MPa which is lower than current design. Thus, it can be concluded that the new proposed design better than current design in term of contact stress. While, the different flexion angle do gives an impact on the performance of the TKA.


1994 ◽  
Vol 43 (2) ◽  
pp. 565-570
Author(s):  
Masahiko Matsumoto ◽  
Takehiko Torisu ◽  
Masahiko Nakamura ◽  
Yuzo Tanaka ◽  
Shogo Masumi

Author(s):  
Shouye Hu ◽  
Chao Lu ◽  
Zhi Yang ◽  
Kan Peng

Objective: The use of screws and cement is a well–known technique for repairing proximal tibial bone defects during primary total knee arthroplasty (TKA). The purpose of this study was to summarize our experience of using of screws and cement for R and C tibial bone defects in primary TKA.


Sign in / Sign up

Export Citation Format

Share Document