scholarly journals Assessment of Age-Related Morphometric Changes of Subcortical Structures in Healthy People Using Ultra-High Field 7 Tesla Magnetic Resonance Imaging

Author(s):  
Xue-Yuan Wang ◽  
Lei Zhao ◽  
Tao Yu ◽  
Liang Qiao ◽  
Duan-Yu Ni ◽  
...  
Author(s):  
JC Lau ◽  
J DeKraker ◽  
KW MacDougall ◽  
H Joswig ◽  
AG Parrent ◽  
...  

Background: The hippocampus can be divided longitudinally into the head, body, and tail; and unfolded medial-to-laterally into the subiculum, cornu ammonis (CA) sectors, and the dentate gyrus. Ultra-high field (≥ 7 Tesla; 7T) magnetic resonance imaging (MRI) enables submillimetric visualization of these hippocampal substructures which could be valuable for surgical targeting. Here, we assess the feasibility of using 7T MRI in conjunction with a novel computational unfolding method for image-based stereotactic targeting of hippocampal substructures. Methods: 53 patients with drug-resistant epilepsy were identified undergoing first-time implantation of the hippocampus. An image processing pipeline was created for computationally transforming post-operative electrode contact locations into our hippocampal coordinate system. Results: Of 178 implanted hippocampal electrodes (88 left; 49.4%), 25 (14.0%) were predominantly in the subiculum, 85 (47.8%) were in CA1, 23 (12.9%) were in CA2, 18 (10.1%) were in CA3/CA4, and 27 (15.2%) were in dentate gyrus. Along the longitudinal axis, hippocampal electrodes were most commonly implanted in the body (92; 51.7%) followed by the head (86; 48.3%). Conclusions: 7T MRI enables high-resolution anatomical imaging on the submillimeter scale in in vivo subjects. Here, we demonstrate the utility of 7T imaging for identifying the relative location of SEEG electrode implantations within hippocampal substructures for the invasive investigation of epilepsy.


NeuroImage ◽  
2020 ◽  
Vol 221 ◽  
pp. 117200 ◽  
Author(s):  
Anneke Alkemade ◽  
Martijn J Mulder ◽  
Josephine M Groot ◽  
Bethany R Isaacs ◽  
Nikita van Berendonk ◽  
...  

PLoS ONE ◽  
2015 ◽  
Vol 10 (6) ◽  
pp. e0129371 ◽  
Author(s):  
Tim Herrmann ◽  
Johannes Mallow ◽  
Markus Plaumann ◽  
Michael Luchtmann ◽  
Jörg Stadler ◽  
...  

2020 ◽  
Vol 376 (1815) ◽  
pp. 20200040 ◽  
Author(s):  
Kimberly B. Weldon ◽  
Cheryl A. Olman

Functional magnetic resonance imaging (fMRI) studies with ultra-high field (UHF, 7+ Tesla) technology enable the acquisition of high-resolution images. In this work, we discuss recent achievements in UHF fMRI at the mesoscopic scale, on the order of cortical columns and layers, and examine approaches to addressing common challenges. As researchers push to smaller and smaller voxel sizes, acquisition and analysis decisions have greater potential to degrade spatial accuracy, and UHF fMRI data must be carefully interpreted. We consider the impact of acquisition decisions on the spatial specificity of the MR signal with a representative dataset with 0.8 mm isotropic resolution. We illustrate the trade-offs in contrast with noise ratio and spatial specificity of different acquisition techniques and show that acquisition blurring can increase the effective voxel size by as much as 50% in some dimensions. We further describe how different sources of degradations to spatial resolution in functional data may be characterized. Finally, we emphasize that progress in UHF fMRI depends not only on scientific discovery and technical advancement, but also on informal discussions and documentation of challenges researchers face and overcome in pursuit of their goals. This article is part of the theme issue ‘Key relationships between non-invasive functional neuroimaging and the underlying neuronal activity’.


2020 ◽  
Vol 16 (S5) ◽  
Author(s):  
Alexa Haeger ◽  
Arthur Coste ◽  
Cécile Lerman‐Rabrait ◽  
Julien Lagarde ◽  
Jörg B. Schulz ◽  
...  

2013 ◽  
Vol 39 (4) ◽  
pp. 398-404 ◽  
Author(s):  
D. Slattery ◽  
C. Aland ◽  
G. Durbridge ◽  
G. Cowin

This study reviews the literature on the anatomy of the connective tissues surrounding the distal interphalangeal joint and further characterizes the three-dimensional relationships of these structures with ultra-high field magnetic resonance imaging. Ten cadaver fingers, fixed in a solution of 5% agar and 4% formalin, were imaged utilising an ultrashield 16.4 Tesla ultra-high field magnetic resonance imaging, yielding a total of 4000 images. Images were analysed using Osirix™ (version 5.5.1 32 bit edition) for three-dimensional reconstruction. We found numerous conflicting descriptions of the connective tissue structures around the distal interphalangeal joint. Based upon our literature review and imaging studies we have defined precisely Cleland’s ligaments, the oblique proximal septum, Grayson’s ligaments, the dorsal plate, and the interosseous ligaments of the distal interphalangeal joint.


2011 ◽  
pp. 189-213 ◽  
Author(s):  
Siegfried Trattnig ◽  
Klaus Friedrich ◽  
Wolfgang Bogner ◽  
Klaus Scheffler ◽  
Oliver Bieri ◽  
...  

2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 1838-1838
Author(s):  
D. Roche ◽  
C. Michel ◽  
P. Daudé ◽  
A. Le Troter ◽  
C. Chagnaud ◽  
...  

Background:Fibrocartilaginous enthesis is composed of different histological zones which are commonly referred to the tendon distal extremity (a lamellar tissue with a low cell density, collagen and connective tissue), the fibrocartilaginous zone (with chondrocytes), a progressively mineralized zone and the bone. The MRI visualization of the water content of entheses is challenging given the very short relation time so that entheses has been very poorly assessed using MRI (1).Objectives:The main objective of the study was to assess the structural elements of the knee enthesis based on the quantitative T2* measurements using Ultra High Field (UHF) MRI.Methods:Twelve healthy subjects without any osteoarticular pathology were included in the study after they provided their informed consent. 3D gradient echo sequence with a 4.3 ms echo time and T2* mapping were performed. The lateral internal, external and crossed ligaments, patellar and quadricipital tendons were assessed. T2* measurements were performed specifically on the quadricipital tendon.Results:The quadricipital tendon and the bone trabeculation could be visualized on the UHF MR image. The T2* mapping analysis illustrated a large value (16.4 ± 4 ms) for the subchondral bone and much lower values for the trabecular bone (11 ± 4.5 ms) and the different zones of the keen entheses (7.7 ± 1.9 ms).Conclusion:Based on T2* measurements performed using UHF MRI, the different structural elements of the knee entheses were distinguished. This quantitative stratification could be used to assess changes in pathological conditions such as SpA and trauma.References:[1]Benjamin M, Bydder GM. Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences. Journal of magnetic resonance imaging: JMRI. 2007;25(2):381-9.Disclosure of Interests:None declared


Sign in / Sign up

Export Citation Format

Share Document