scholarly journals Size of Patent Ductus Arteriosus and Echocardiographic Markers of Shunt Volume in Preterm Infants Based on Postnatal Age

2021 ◽  
Vol 9 ◽  
Author(s):  
Eui Kyung Choi ◽  
Kyu Hee Park ◽  
Byung Min Choi

Objective: This study was conducted in order to compare the strength of correlation between echocardiographic markers of shunt volume and patent ductus arteriosus (PDA) diameter based on postnatal age.Methods: This retrospective study focused on preterm infants (aged <32 weeks of gestation) admitted to the Neonatal Intensive Care Unit of Korea University Ansan Hospital, between April 2014 and December 2017, who studied serial targeted neonatal echocardiography (TNE) for PDA during hospitalization. The association between echocardiographic characteristics and duct size was divided into the following days: within 3 days (very early, VE), 4–7 days after birth (early, E), and after 8 days of birth (late, L).Results: We found 113 assessments conducted on 57 infants in the VE period, 92 assessments on 40 infants in the E period, and 342 assessments on 37 infants in the L period. Median gestational age and birth weight were 28+2 weeks of gestation and 1,115 g, respectively. In the univariate regression analysis, we found a statistically significant correlation between PDA diameter and all TNE markers in the E and L days, but not in the VE period. Only ductal velocity [coefficient of determination (R2) = 0.224], antegrade left pulmonary artery diastolic flow velocity (R2 = 0.165), left ventricular output (LVO)/superior vena cava (SVC) flow ratio (R2 = 0.048), and E/A wave ratio (R2 = 0.092) showed weak correlations with PDA diameter in the VE period. The slopes of the regressions showed significant changes based on postnatal age in the maximum ductal velocity, left atrium/aorta ratio, LVO/SVC flow ratio, and LVO.Conclusions: It is difficult to predict the echocardiographic markers of shunt volume based on the PDA diameter in preterm infants younger than 4 days. A better understanding of the changes in the hemodynamic consequences of PDA based on postnatal age is needed when considering treatment.

Author(s):  
Michael P. Castaldo ◽  
Elaine Neary ◽  
Adrianne R. Bischoff ◽  
Dany E. Weisz ◽  
Amish Jain ◽  
...  

Objective An alternative therapy for preterm infants with a hemodynamically significant patent ductus arteriosus (hsPDA) is needed when cyclooxygenase inhibitors fail or where treatment is contraindicated due to coexisting renal failure, necrotizing enterocolitis, and/or intestinal perforation. No studies have evaluated the efficacy of per rectum (PR) acetaminophen. The study aimed to evaluate the efficacy of PR acetaminophen in modulating the risk of PDA ligation. Study Design A retrospective matched case–control study was conducted to compare neonates born <29 weeks' gestation with evidence of hsDA, in an era when rescue rectal acetaminophen was used (January 2014–March 2018) as a treatment strategy, versus historical controls (July 2006–August 2012). All patients underwent comprehensive echocardiography assessment of ductal shunt volume according to a standardized protocol. Acetaminophen treated neonates were matched according to demographics, gestation, preintervention echocardiography features, and comorbidities. Control patients were selected when an echocardiography was performed at an equivalent postnatal age. Infants with a genetic syndrome, severe congenital malformation, or major forms of congenital heart disease excluding small atrial septal defect or ventricular septal defect, PDA, or patent formale ovale were excluded. The primary outcome was surgical ligation of the PDA. Secondary outcomes included echocardiography indices of hemodynamic significance, the composite of death, or severe BPD (defined by ventilator dependence at 36 weeks postmenstrual age). Descriptive statistics and univariate (t-tests, Fisher's exact test, and Mann–Whitney U test) analyses were used to evaluate clinical and echocardiography characteristics of the groups and compare outcomes. Results Forty infants (20 cases and 20 controls), with similar demographic and echocardiography features, were compared. Cases received 6.8 ± 0.7 days (60 mg/kg/day) of PR acetaminophen. Responders (n = 12, 60%) had echocardiography evidence of reduced ductal diameter (2.2 mm [1.9–2.6] to 1.1 mm [0–1.7], p = 0.002), left ventricular output (363 ± 108–249 ± 61 mL/min/kg; p = 0.002) and left atrium to aortic root ratio (1.7 ± 0.3–1.3 ± 0.2; p = 0.002) following treatment. The rate of PDA ligation was 50% lower (p = 0.02) and composite outcome of death or severe bronchopulmonary dysplasia was reduced (p = 0.04) in the acetaminophen group. Conclusion Rectal acetaminophen was associated with improvement in echocardiography indices of PDA shunt volume, a 50% reduction in PDA ligation rates and a reduction in the composite outcome of death or severe BPD. Pharmacologic and further prospective clinical studies are needed. Key Points


2021 ◽  
Author(s):  
Adrianne Rahde Bischoff ◽  
Regan E. Giesinger ◽  
Amy H. Stanford ◽  
Ravi Ashwath ◽  
Patrick J. McNamara

2018 ◽  
Vol 83 (5) ◽  
pp. 1016-1023 ◽  
Author(s):  
Sigrid Baumgartner ◽  
Monika Olischar ◽  
Martin Wald ◽  
Tobias Werther ◽  
Angelika Berger ◽  
...  