scholarly journals Vertical Seismic Isolation Device for Three-Dimensional Seismic Isolation of Nuclear Power Plant Equipment—Case Study

2021 ◽  
Vol 12 (1) ◽  
pp. 320
Author(s):  
Gyeong-Hoi Koo ◽  
Jin-Young Jung ◽  
Jong-Keun Hwang ◽  
Tae-Myung Shin ◽  
Min-Seok Lee

The purpose of this study was to develop a vertical seismic isolation device essential for the three-dimensional seismic isolation design of nuclear power plant equipment. The vertical seismic isolation device in this study has a concept that can be integrally combined with a conventional laminated rubber bearing, a horizontal seismic isolator with a design vertical load of 10 kN. To develop the vertical seismic isolation device, the vertical spring and the seismic energy dissipation device capable of limiting the vertical displacement of the spring were designed and their performances were verified through actual tests. In this study, the target elevation of the floor is 136 ft, where safety-related nuclear equipment, such as cabinet and remote shutdown console, etc., is installed. The sensitivity studies were carried out to investigate the optimal design vertical isolation frequencies for the target building elevation. Based on the results of the sensitivity study, a disc spring and a helical coil spring were selected for the vertical stiffness design, and the steel damper was selected for the seismic energy dissipation, and their performance characteristics were tested to confirm the design performance. For the steel damper, three types were designed and their energy dissipation characteristics by hysteretic behavior were confirmed by the inelastic finite element analyses and the tests in static fully reversed cyclic conditions. Through the study of the vertical seismic isolation device, it was found that 2.5 Hz~3.0 Hz is appropriate for the optimal design vertical isolation. With results of the vertical seismic isolation performance analysis, the appropriate number of steel dampers are proposed to limit the vertical seismic displacement of the spring within the static displacement range by the design vertical load.

Author(s):  
H. Heki ◽  
M. Nakamaru ◽  
T. Maruyama ◽  
H. Hirai ◽  
M. Aritomi

LSBWR (Long operating cycle Simplified BWR) is a modular, direct cycle, light water cooled, and small power (100–300MWe) reactor. The design considers requirements from foreign utilities as well as from Japanese. LSBWR is currently being developed by Toshiba Corporation and Tokyo Institute of Technology. Major characteristics of the LSBWR are: 1) Long operating cycle (target: over 15 years), 2) Simplified systems and building, 3) Factory fabrication in module. From the perspective of economic improvement of nuclear power plant, it is needed to shorten the plant construction period and to reduce building volume. In designing LSBWR building, a new building structure, where the hull structure of a ship is applied to floors and walls of LSBWR has been studied. Since the hull structure is manufactured at a shipyard, building module that includes plant equipment becomes possible. The application of the hull structure, which can make large modules at a shipyard, is an effective solution to the lack of laborer and economic improvement. LSBWR is a small size BWR, turbine is smaller size and lighter weight than medium or larger size plant. Then, it has been studied to install a reactor and a turbine in the same building for decreasing building volume. From the view point of standardization, whole building is supported by three dimensional seismic isolation mechanism.


Author(s):  
Mitsuru Kageyama ◽  
Yoshihiko Hino ◽  
Satoshi Moro

In Japan, the development of the next generation NPP has been conducted in recent years. In the equipment/piping design of the plant, seismic condition has been required much more mitigate than before. So, the three-dimensional (abbreviation to 3D) seismic isolation system development has also been conducted since 2000. The superlative 3D base isolation system for the entire building was proposed. The system is composed of cable reinforced air springs, rocking arresters and viscous dampers. Dimensions of the air spring applied to the actual power plant are 8 meters in the outer-diameter and 3.5 meters in height. The allowable half strokes are 1.0 meters in horizontal and 0.5 meters in vertical respectively. The maximum supporting weight for a single device is 70 MN. The inner design air pressure is about 1.8MPa. This air spring has a distinguishing feature, which realizes 3D base isolation with a single device, whose natural periods are about 4 seconds in horizontal and about 3 seconds in vertical. In order to verify the 3D performance of this system, several feasibility tests were conducted. Firstly, 3D shaking table tests were conducted. The test specimen is scaled 1/4 of the actual device. The outer diameter and inner air pressure of air spring is 2 meters and 0.164 MPa. Next, a pressure resistant test for the sub cable, textile sheet and rubber sheet, which composed air spring, were conducted as a full scale model test. Then, air permeation test for the rubber sheet was also conducted. As a result, the proposed system was verified that it could be applied to the actual nuclear power plants.


Author(s):  
Takahiro Shimada ◽  
Junji Suhara ◽  
Kazuhiko Inoue

Three dimensional (3D) seismic isolation devices have been developed to use for the base isolation system of the heavy building like a nuclear reactor building. The developed seismic isolation system is composed of rolling seal type air springs and the hydraulic type springs with rocking suppression system for vertical base isolation device. In horizontal direction, the same laminated rubber bearings are used as horizontal isolation device for these systems. The performances and the applicability have already been evaluated by the technical feasibility tests and performance tests for each system. In this study, it was evaluated that the performance of the 3D base isolation system with rolling seal type air springs combined with hydraulic rocking suppression devices. A 1/7 scaled model of the 3D base isolation devices were manufactured and some performance test were executed for each device. For the rolling seal type air springs, dynamic loading test was executed with a vibration table, and pressure resistant ability test was executed for reinforced air springs. In the dynamic loading test, it is confirmed that the natural period and damping performance were verified. In the pressure resistant ability test, it is confirmed that the air springs had sufficient strength. For the hydraulic rocking suppression system, forced dynamic loading test was carried out in order to measure the frictional and oil flow resistance force on each cylinder. And the vibration table tests were carried out with supported weight of 228 MN in order to evaluate and to confirm the horizontal and vertical isolation performance, rocking suppression performance, and the applicability of the this seismic isolation system as the combined system. 4 rolling seal type air springs and 4 hydraulic load-carrying cylinders with rocking suppression devices supported the weight. As a result, the proposed system was verified that it could be applied to the actual nuclear power plant building to be target.


Author(s):  
Alexandre Borsoi ◽  
Satoshi Fujita ◽  
Keisuke Minagawa

In Japan, the application of seismic isolation systems using rubber bearings to industrial structure and new generation Nuclear Power Plants have been considered in order to enhance seismic safety. However, the isolation performance will decline in case of huge earthquakes, because of the nonlinearity of both horizontal and vertical restoring characteristics of the rubber bearings. The horizontal restoring force has a hardening characteristic and the vertical restoring force has a softening characteristic. In addition, the horizontal nonlinearity depends on vertical load, so the interaction between the horizontal and vertical response is important. Consequently, in this paper, the analysis of the nonlinearity of the rubber bearings and the coupling between those two directions will be carried out. Then, after comparing these two approaches, the utility of considering this dependency will be estimated. To do so, a simulation program, based on the Runge-Kutta-Gill’s method has been developed in order to evaluate the seismic response of the isolated structure composed of rubber bearings and oil dampers. The nonlinearity of the rubber bearings is considered, and the coupling of the vertical load and the horizontal hardening has been implemented.