scholarly journals Performance Analysis of a Small-Scale Biogas-Based Trigeneration Plant: An Absorption Refrigeration System Integrated to an Externally Fired Microturbine

Energies ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3830 ◽  
Author(s):  
Villarroel-Schneider ◽  
Malmquist ◽  
Araoz ◽  
Martí-Herrero ◽  
Martin

Trigeneration or combined cooling, heat and power (CCHP) systems fueled by raw biogas can be an interesting alternative for supplying electricity and thermal services in remote rural areas where biogas can be produced without requiring sophisticated equipment. In this sense, this study considers a performance analysis of a novel small-scale CCHP system where a biogas-fired, 5 kWel externally fired microturbine (EFMT), an absorption refrigeration system (ARS) and heat exchangers are integrated for supplying electricity, refrigeration and hot water demanded by Bolivian small dairy farms. The CCHP solution presents two cases, current and nominal states, in which experimental and design data of the EFMT performance were considered, respectively. The primary energy/exergy rate was used as a performance indicator. The proposed cases show better energy performances than those of reference fossil fuel-based energy solutions (where energy services are produced separately) allowing savings in primary energy utilization of up to 31%. Furthermore, improvements in electric efficiency of the EFMT and coefficient of performance (COP) of the ARS, identified as key variables of the system, allow primary energy savings of up to 37%. However, to achieve these values in real conditions, more research and development of the technologies involved is required, especially for the EFMT.

Author(s):  
Yoon Jo Kim ◽  
Sarah Kim ◽  
Yogendra K. Joshi ◽  
Andrei G. Fedorov ◽  
Paul A. Kohl

An ionic-liquid (IL) is a salt in a liquid state usually with an organic cation and inorganic anion. ILs provide an alternative to the normally toxic working fluids in absorption systems, such as the ammonia/water system. They also eliminate the problems of poor temperature match, crystallization and metal-compatibility problems of the water/LiBr system. In the present study, an IL is explored the working fluid of a miniature absorption refrigeration system so as to utilize waste-heat within the system for low-cost, high-power electronics cooling. To determine performance benchmarks for the refrigerant/IL (e.g. [bmim][PF6]) pairs, system-level simulations have been carried out. An NRTL model was built and used to predict the solubility of the mixture as well as the mixture properties such as enthalpy and entropy. The properties of the refrigerants were determined using REFPROP 6.0. Saturation temperatures at the evaporator and condenser were 25°C and 50°C, respectively. Chip power was fixed at 100 W with the operating temperature set at 85°C. R32 gave the highest operating efficiency with the maximum coefficient of performance (COP) of ca. 0.55 while R134a and R152a showed comparable performance with the maximum COP of ca. 0.4 at the desorber outlet temperature of 80°C. When waste-heat is available for the system operation, R134a and R152a COPs were comparable or better than that of R32.


2014 ◽  
Vol 953-954 ◽  
pp. 752-756
Author(s):  
Qi Chao Yang

The absorption thermal energy storage (TES) system stores the energy in the form of potential energy of solution and is a promising technology for efficient energy transformation process. The performance of the absorption refrigeration system with integral storage for cooling applications using LiBr-H2O as working pair under the condition without crystallization was analyzed on the basis of the first law of thermodynamics. Simulation was employed to determine the coefficient of performance (COP) and energy storage density (ESD) of the absorption TES system under different conditions such as the absorption temperature and storage temperature. The results show that the COP of the system is 0.7453 and ESD is 169.853 MJ/m3 under typical operation conditions in summer. A low absorption temperature yields both a higher COP and ESD. The solution heat exchanger could improve the COP of the system while has no effect on ESD. Results also showed that system has a good advantage when compared to other storage methods since it is do no need thermal insulation. The absorption TES may be considered as one of the promising thermal energy storage methods.


2009 ◽  
Vol 46 (2) ◽  
pp. 137-145 ◽  
Author(s):  
Suleiman Qaseem Abu-Ein ◽  
Sayel M. Fayyad ◽  
Waleed Momani ◽  
Mamdouh Al-Bousoul

Sign in / Sign up

Export Citation Format

Share Document