scholarly journals Impact of an Energy Monitoring System on the Energy Efficiency of an Automobile Factory: A Case Study

Energies ◽  
2020 ◽  
Vol 13 (10) ◽  
pp. 2577 ◽  
Author(s):  
Tehseen Akhtar ◽  
Asif Ur Rehman ◽  
Mohsin Jamil ◽  
Syed Omer Gilani

Energy-saving strategies cannot be implemented without having detailed and regular power consumption data of a facility. The installation of an energy monitoring and data logging system can help in planning energy efficiency improvement policies by providing daily, monthly, and yearly energy consumption reports and graphs. The purpose of this study was to demonstrate the impact of an energy monitoring and management system on the improvement of energy efficiency in the industrial sector of developing countries. This study introduced an energy monitoring and data logging system installed in an automobile factory in Pakistan. Energy consumption data, which also included power quality data, were collected with the help of energy analyzers and transmitted to a centralized supervisory control and data acquisition (SCADA) software for data logging and monitoring purposes. This system was developed by combining Modbus with industrial Ethernet to communicate real-time energy consumption data of the factory to multiple local and remote locations. Monitoring and logging the real-time energy consumption data helped the user to find the significant energy losses inside the factory and to implement various energy conservation policies inside the facility, resulting in energy efficiency improvement. The energy consumption results indicate that the proposed system can help achieve an approximately 8% improvement in energy efficiency.

2008 ◽  
pp. 55-61 ◽  
Author(s):  
Bojana Prodanic ◽  
Aleksandar Jokic ◽  
Jelena Markovic ◽  
Zoltan Zavargo

General trend of free trade at the regional level as well as in the direction of European Union has motivated sugar factories located in Serbia to invest into technologies that are more efficient in order to make their products more competitive in the markets of Europe. Until 2005, the project of energy efficiency improvement in Serbian sugar factories was conducted in Crvenka and Zabalj. Now, they have energy consumption around 1 MJ/kg beet, in contrast to the previous consumption of 1.2 up to 1.5 MJ/kg beet. Further improvements are possible but investments would be high. A result of measurements taken during 2006, after the sugar factory "Donji Srem" - Pecinci was reconstructed showed that a considerable saving has been achieved. The first set of measurements showed that the energy consumption was 1.01 MJ/kg beet, which was 20% higher than intended, but at the same time energy savings were about 30% lower with respect to the values before the reconstruction.


2021 ◽  
Vol 18 (1) ◽  
pp. 95-114
Author(s):  
Ana Radojevic ◽  
Danijela Nikolic ◽  
Jasna Radulovic ◽  
Jasmina Skerlic

The implementation of energy efficiency measures and use of renewable energy sources in educational buildings can significantly contribute to reducing energy consumption, but also to CO2 emissions in the entire public sector. The paper shows the comparison of energy consumption indicators for 61 elementary school buildings which have previously been divided in 12 groups, according to the period of construction and size, based on the national typology called TABULA, as the first step of further study on how to use the renewable energy sources. The aim of this paper is to use the energy benchmarking process to select representative facilities which are suitable for applying renewable energy sources, for their further energy efficiency improvement. Indicators of annual specific electricity consumption and CO2 emissions per unit area [kWh/m2] and per user [kWh/user] were calculated. After that, from two groups (in which the highest electricity consumption and CO2 emissions are 68.37% and 74.53% of the total consumption/ emissions), one representative facility was selected.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Shankara Naik ◽  
Virupaxi Bagodi

Purpose The purpose of the paper is to examine the monitoring of electrical energy consumption, measures adopted for reducing energy consumption, barriers to energy efficiency improvement and driving forces for energy efficiency improvement in three industrial clusters. It is intends to capture the managerial perspectives on energy saving practices and to identify the possible energy saving opportunities in small and medium enterprises (SMEs). Design/methodology/approach Three industrial clusters were identified for the study. Research instrument based in-person survey was conducted in which the authors directly administered the questionnaire to all the 181 organisations. This was thought of to facilitate not so well-educated respondents. The survey took about six months in which 110 units responded. Descriptive statistics, exploratory factor analysis and path analysis were used to draw inferences. Findings There is ample scope for energy savings in the studied clusters. Energy efficiency in many organisations has deteriorated. Their attitude to embrace new or modern technology is shunning. Management’s belief that prevailing technology is efficient, lack of skilled labour, lack of accessibility to updated or modern technology, and lack of compatibility of new technology are found to be the barriers to energy efficiency improvement. Benchmarking by appropriate governments and publicly financed energy auditing act as the driving forces. Originality/value The SMEs must use simple yet powerful energy auditing practices on regular basis to reduce energy consumption. This will not only result in lesser energy costs but also lessen the burden on environment. As these are predominantly small enterprises, appropriate governments interventions are essential to bring the desired change.


2021 ◽  
Author(s):  
Saqib Sajjad ◽  
Haseeb Ali

Abstract Process refrigeration units are one of the major energy consumers at gas processing plants. Owing to the higher energy consumption, evaluation and benchmarking of energy performance of the refrigeration units is very important for identification of energy saving opportunities. In this regard, an energy performance benchmarking study was performed by detailed assessment and evaluation of the existing process refrigeration units to identify potential of energy efficiency improvement. The study encompassed twenty-one (21) process refrigeration units installed at five (05) different sites. The methodology included collection and analysis of design & operation data and review of key variables like percent load, anti-surge valve opening, condensing temperature & pressure and chilling temperature etc. Energy Performance Indicators (EnPIs) considered for the benchmarking were compressor's specific energy, coefficient of performance (COP) and relative COP (RCOP). A thermodynamic model was developed for each unit to ascertain the refrigeration load. Instead of usual high level benchmarking techniques, the study considered unit and equipment level benchmarking which provided better insight of the systems and helped in finding opportunities for energy efficiency improvement. Further, COP which is generally considered as a benchmarking EnPI, only considers refrigeration load and energy consumption, whereas, this study introduced a new EnPI named "Relative COP" which additionally takes into account the chilling and condensing temperatures and gives true energy performance benchmarking.


Sign in / Sign up

Export Citation Format

Share Document