scholarly journals Early Development of Newborn Screening for HCU and Current Challenges

2021 ◽  
Vol 7 (4) ◽  
pp. 67
Author(s):  
Harvey L. Levy

Classic homocystinuria (HCU) was added to newborn screening (NBS) by Robert Guthrie a few years after the disorder was first described. The justification for NBS was similar to that for PKU, that presymptomatic identification and early dietary treatment would prevent the clinical consequences, which, for HCU, are mental deficiency, ectopia lentis, skeletal abnormalities, and thromboembolism. It was assumed that identifying increased methionine in the screening blood specimen would identify all affected neonates. However, it is now clear that many with HCU are missed by NBS, mainly because the methionine level in the first days of life is normal or below the cutoff level in the NBS program. This includes virtually all of those with B6-responsive HCU. Thus, a more effective method of NBS for HCU should be considered. Included among the possibilities are decreasing the methionine cutoff level, requiring an increase in the Met/Phe ratio if the methionine level is not at or greater than the cutoff level, using methionine as the primary screen with homocysteine as a second-tier test, or replacing methionine with homocysteine as the primary screen. Homocysteine is the primary metabolite that increases in HCU, while the methionine increase is secondary, so homocysteine is usually increased before the increase in methionine, almost always during the first few days of life. Finally, targeted gene screening might be considered. All of these possibilities would impose added expense and labor to NBS, so meeting these challenges would likely require a regional or national effort.

2016 ◽  
Vol 15 (6) ◽  
pp. 752-758 ◽  
Author(s):  
Sophia Weidler ◽  
Konrad H. Stopsack ◽  
Jutta Hammermann ◽  
Olaf Sommerburg ◽  
Marcus A. Mall ◽  
...  

2008 ◽  
Vol 54 (3) ◽  
pp. 542-549 ◽  
Author(s):  
Devin Oglesbee ◽  
Karen A Sanders ◽  
Jean M Lacey ◽  
Mark J Magera ◽  
Bruno Casetta ◽  
...  

Abstract Background: Newborn screening for maple syrup urine disease (MSUD) relies on finding increased concentrations of the branched-chain amino acids (BCAAs) leucine, isoleucine, and valine by tandem mass spectrometry (MS/MS). d-Alloisoleucine (allo-Ile) is the only pathognomonic marker of MSUD, but it cannot be identified by existing screening methods because it is not differentiated from isobaric amino acids. Furthermore, newborns receiving total parenteral nutrition often have increased concentrations of BCAAs. To improve the specificity of newborn screening for MSUD and to reduce the number of diet-related false-positive results, we developed a LC-MS/MS method for quantifying allo-Ile. Methods: Allo-Ile and other BCAAs were extracted from a 3/16-inch dried blood spot punch with methanol/H2O, dried under nitrogen, and reconstituted into mobile phase. Quantitative LC-MS/MS analysis of allo-Ile, its isomers, and isotopically labeled internal standards was achieved within 15 min. To determine a reference interval for BCAAs including allo-Ile, we analyzed 541 dried blood spots. We also measured allo-Ile in blinded samples from 16 MSUD patients and 21 controls and compared results to an HPLC method. Results: Intra- and interassay imprecision (mean CVs) for allo-Ile, leucine, isoleucine, and valine ranged from 1.8% to 7.4%, and recovery ranged from 91% to 129%. All 16 MSUD patients were correctly identified. Conclusions: The LC-MS/MS method can reliably measure allo-Ile in dried blood spots for the diagnosis of MSUD. Applied to newborn screening as a second-tier test, it will reduce false-positive results, which produce family anxiety and increase follow-up costs. The assay also appears suitable for use in monitoring treatment of MSUD patients.


2009 ◽  
Vol 55 (12) ◽  
pp. 2207-2213 ◽  
Author(s):  
Barbara W Adam ◽  
Timothy H Lim ◽  
Elizabeth M Hall ◽  
W Harry Hannon

Abstract Background: Succinylacetone (SUAC) is the primary metabolite accumulated in tyrosinemia type I—an inborn error of metabolism that, if untreated, can cause death from liver failure during the first months of life. Newborn screening laboratories measure SUAC in dried blood spot (DBS) samples to detect asymptomatic tyrosinemia type I. We used panels of SUAC-enriched DBSs to compare and evaluate the performance of these screening tests. Methods: We prepared sets of DBS materials enriched with predetermined SUAC concentrations and distributed samples of these materials, along with a screening practices questionnaire, to laboratories that perform SUAC tests. We compared their reported SUAC concentrations and questionnaire responses to identify screening practices that affect SUAC test outcomes. Results: Data from 2 pilot surveys showed large differences among laboratories in SUAC recoveries, reproducible within-laboratory recoveries, and stable performance of the DBS materials. Results from 257 proficiency test analyses contained a total of 6 false-negative misclassifications. Reported recoveries of added SUAC ranged from 0 to >200%. Low-biased SUAC recoveries were associated with 1 method used by 5 laboratories. All laboratories that reported SUAC recoveries ≥100% used DBS matrix calibrators. Conclusions: The wide ranges of SUAC concentrations reported for pilot and proficiency testing specimens demonstrate a need to harmonize quantitative results among laboratories. Although DBS matrix calibrators are important for optimizing SUAC recoveries, the preparation of these calibrators is not standardized among laboratories. Certified DBS-based SUAC calibrators are needed for accuracy and harmonization.


2020 ◽  
Vol 6 (3) ◽  
pp. 51 ◽  
Author(s):  
Trine Tangeraas ◽  
Ingjerd Sæves ◽  
Claus Klingenberg ◽  
Jens Jørgensen ◽  
Erle Kristensen ◽  
...  

In 2012, the Norwegian newborn screening program (NBS) was expanded (eNBS) from screening for two diseases to that for 23 diseases (20 inborn errors of metabolism, IEMs) and again in 2018, to include a total of 25 conditions (21 IEMs). Between 1 March 2012 and 29 February 2020, 461,369 newborns were screened for 20 IEMs in addition to phenylketonuria (PKU). Excluding PKU, there were 75 true-positive (TP) (1:6151) and 107 (1:4311) false-positive IEM cases. Twenty-one percent of the TP cases were symptomatic at the time of the NBS results, but in two-thirds, the screening result directed the exact diagnosis. Eighty-two percent of the TP cases had good health outcomes, evaluated in 2020. The yearly positive predictive value was increased from 26% to 54% by the use of the Region 4 Stork post-analytical interpretive tool (R4S)/Collaborative Laboratory Integrated Reports 2.0 (CLIR), second-tier biochemical testing and genetic confirmation using DNA extracted from the original dried blood spots. The incidence of IEMs increased by 46% after eNBS was introduced, predominantly due to the finding of attenuated phenotypes. The next step is defining which newborns would truly benefit from screening at the milder end of the disease spectrum. This will require coordinated international collaboration, including proper case definitions and outcome studies.


2020 ◽  
Vol 6 (1) ◽  
pp. 10 ◽  
Author(s):  
Dawn S. Peck ◽  
Jean M. Lacey ◽  
Amy L. White ◽  
Gisele Pino ◽  
April L. Studinski ◽  
...  

Enzyme-based newborn screening for Mucopolysaccharidosis type I (MPS I) has a high false-positive rate due to the prevalence of pseudodeficiency alleles, often resulting in unnecessary and costly follow up. The glycosaminoglycans (GAGs), dermatan sulfate (DS) and heparan sulfate (HS) are both substrates for α-l-iduronidase (IDUA). These GAGs are elevated in patients with MPS I and have been shown to be promising biomarkers for both primary and second-tier testing. Since February 2016, we have measured DS and HS in 1213 specimens submitted on infants at risk for MPS I based on newborn screening. Molecular correlation was available for 157 of the tested cases. Samples from infants with MPS I confirmed by IDUA molecular analysis all had significantly elevated levels of DS and HS compared to those with confirmed pseudodeficiency and/or heterozygosity. Analysis of our testing population and correlation with molecular results identified few discrepant outcomes and uncovered no evidence of false-negative cases. We have demonstrated that blood spot GAGs analysis accurately discriminates between patients with confirmed MPS I and false-positive cases due to pseudodeficiency or heterozygosity and increases the specificity of newborn screening for MPS I.


2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Anna Caciotti ◽  
Elena Procopio ◽  
Francesca Pochiero ◽  
Silvia Falliano ◽  
Giuseppe Indolfi ◽  
...  

Abstract We describe a 14-month-old boy, with a previous diagnosis of propionic acidemia (PA) by expanded newborn screening, who, admitted for a suspected metabolic crisis, tested positive for SARS-CoV-2. Since propionic acidemia was diagnosed, the patient has followed the recommended diet for this inborn error of metabolism. Although propionic acidemia patients are at a high risk of suffering metabolic crises, frequently associated with permanent clinical complications, psychomotor development of this patient was normal. The SARS-CoV-2 infection (at about 1 year of age) caused the patient’s first metabolic crisis. However, his clinical course was in keeping with a mild clinical form of COVID-19, and he recovered without experiencing severe clinical consequences. We describe this patient in order to improve the knowledge about follow up of PA patients identified by newborn screening and to increase the limited number of reports of SARS-CoV-2 infection in children with comorbidities, especially inborn errors of metabolism.


2020 ◽  
Vol 6 (2) ◽  
pp. 33 ◽  
Author(s):  
Dimitar K. Gavrilov ◽  
Amy L. Piazza ◽  
Gisele Pino ◽  
Coleman Turgeon ◽  
Dietrich Matern ◽  
...  

The expansion of the recommend uniform screening panel to include more than 50 primary and secondary target conditions has resulted in a substantial increase of false positive results. As an alternative to subjective manipulation of cutoff values and overutilization of molecular testing, here we describe the performance outcome of an algorithm for disorders of methionine, cobalamin, and propionate metabolism that includes: (1) first tier screening inclusive of the broadest available spectrum of markers measured by tandem mass spectrometry; (2) integration of all results into a score of likelihood of disease for each target condition calculated by post-analytical interpretive tools created byCollaborative Laboratory Integrated Reports (CLIR), a multivariate pattern recognition software; and (3) further evaluation of abnormal scores by a second tier test measuring homocysteine, methylmalonic acid, and methylcitric acid. This approach can consistently reduce false positive rates to a <0.01% level, which is the threshold of precision newborn screening. We postulate that broader adoption of this algorithm could lead to substantial savings in health care expenditures. More importantly, it could prevent the stress and anxiety experienced by many families when faced with an abnormal newborn screening result that is later resolved as a false positive outcome.


2020 ◽  
Vol 6 (1) ◽  
pp. 23 ◽  
Author(s):  
Anne Bergougnoux ◽  
Maureen Lopez ◽  
Emmanuelle Girodon

There has been considerable progress in the implementation of newborn screening (NBS) programs for cystic fibrosis (CF), with DNA analysis being part of an increasing number of strategies. Thanks to advances in genomic sequencing technologies, CFTR-extended genetic analysis (EGA) by sequencing its coding regions has become affordable and has already been included as part of a limited number of core NBS programs, to the benefit of admixed populations. Based on results analysis of existing programs, the values and challenges of EGA are reviewed in the perspective of its implementation on a larger scale. Sensitivity would be increased at best by using EGA as a second tier, but this could be at the expense of positive predictive value, which improves, however, if EGA is applied after testing a variant panel. The increased detection of babies with an inconclusive diagnosis has proved to be a major drawback in programs using EGA. The lack of knowledge on pathogenicity and penetrance associated with numerous variants hinders the introduction of EGA as a second tier, but EGA with filtering for all known CF variants with full penetrance could be a solution. The issue of incomplete knowledge is a real challenge in terms of the implemention of NBS extended to many genetic diseases.


2018 ◽  
Vol 4 (4) ◽  
pp. 41 ◽  
Author(s):  
Shu-Chuan Chiang ◽  
Pin-Wen Chen ◽  
Wuh-Liang Hwu ◽  
An-Ju Lee ◽  
Li-Chu Chen ◽  
...  

Early diagnosis of lysosomal storage diseases (LSDs) through newborn screening (NBS) has been adapted widely. The National Taiwan University Hospital Newborn Screening Center launched the four-plex tandem mass spectrometry LSD newborn screening test in 2015. The test determined activities of acid α-glucosidase (GAA; Pompe), acid α-galactosidase (GLA; Fabry), acid β-glucocerebrosidase (ABG; Gaucher), and acid α-l-iduronidase (IDUA; MPS-I) in dried blood spots (DBS). Through 2017, 64,148 newborns were screened for these four LSDs. The screening algorithm includes enzyme activity/ratio as the cutoffs for the first screening test and a second-tier test for Pompe disease screening. The second-tier Pompe disease screening test measured activity inhibition by acarbose. Twenty-nine newborns required a confirmatory test; six were confirmed to have Pompe disease, and nine were confirmed to have Fabry disease. The screen-positive rate for Pompe disease was 0.031%. Therefore, in Pompe disease newborn screening, a validated 2nd tier test is necessary to decrease false positives.