scholarly journals Push-Out Bond Strength of Resin-Modified Glass Ionomer Cement and Flowable Composite Luting Systems on Glass Fiber Post of Root Canal

Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6908
Author(s):  
Jalison Jacob Cheruvathoor ◽  
Lincy Rachel Thomas ◽  
Lirin Ann Thomas ◽  
Madhuniranjanswamy Mahalakshmamma Shivanna ◽  
Pramod Machani ◽  
...  

Background: Posts that have been properly fitted can withstand torsion forces and so provide better retention. The push-out bonding strength of glass fiber posts to the root canal was evaluated using resin-modified glass ionomer cement (RMGIC) and flowable composite (FC). Method: Forty single-rooted maxillary central incisors were used in the study. The samples were randomly divided into two groups of 20 teeth each. The crown-down procedure was used to clean and shape the pulp area. A Tenax fiber trans Coltene whaletene post was used by both groups. The first group utilized FC (Filtek Z 350 3M ESPE) to coat the post, whereas the second group used RMGIC (Rely X 3M ESPE). The specimens were cross-sectioned after 24 h. Specimens were cross-sectioned four millimeters thick into coronal and middle parts using a sectioning machine, yielding 40 specimens per group. The strength of the bond between the luting cement and the posts was measured using push-out bond strength testing. We loaded the components at a cross speed of 0.5 mm/min on a universal testing machine until the bond failed. Results: The FC group had a 4.80 N push-out bond strength, whereas the RMGIC group had a 7.11 N push-out bond strength. Conclusion: FC’s mean push-out bond strength score is lower than RMGIC’s.

Author(s):  
Kiana Poorzandpoush ◽  
Mehdi Shahrabi ◽  
Alireza Heidari ◽  
Zohre Sadat Hosseinipour

Objectives: This study aimed to compare the shear bond strength (SBS) of self-adhesive and conventional flowable composites and resin-modified glass-ionomer cement (RMGIC) to primary dentin. Materials and Methods: In this in vitro, experimental study, the buccal surface of 48 primary canine and first molar teeth was longitudinally sectioned to expose dentin. The teeth were randomly divided into three groups (n=16) of 37.5% phosphoric acid+ OptiBond+ Premise Flow composite (group 1), Vertise Flow composite (group 2) and RMGIC (group 3). A plastic cylindrical mold was placed on the exposed dentin and filled with restorative materials. The samples were then immersed in distilled water at 37°C for 24 hours, subjected to 1000 thermal cycles between 5-55°C and underwent SBS test. The mode of failure was determined under a stereomicroscope. Data were analyzed using one-way ANOVA and Tukey’s test. Results: A significant difference was noted in SBS of the groups (P<0.05). The SBS of conventional flowable composite was significantly higher that of RMGIC and self-adhesive flowable composite (P<0.05). The difference in SBS of RMGIC and self-adhesive flowable composite was not significant (P>0.05). Failure at the dentin-restoration interface (adhesive failure) had the highest frequency in groups 1 and 2. The frequency of adhesive failure was 100% in group 3. Conclusions: Within the limitations of this study, the conventional flowable composite yielded the highest SBS to primary dentin. Self-adhesive flowable composite and RMGIC showed the lowest SBS with no significant difference with each other.


2015 ◽  
Vol 16 (12) ◽  
pp. 944-949 ◽  
Author(s):  
Mateus Rodrigues Tonetto ◽  
Milton Carlos Kuga ◽  
Matheus Coelho Bandeca ◽  
Weber Adad Ricci ◽  
José Cláudio Martins Segalla ◽  
...  

ABSTRACT Aim To evaluate the effect of 37% carbamide peroxide on the bond strength of conventional or resin-modified glass-ionomer cements when used as a cervical barrier in endodonticallytreated teeth. Materials and methods After root canal instrumentation and obturation, 40 specimens of the cement-enamel junction were obtained after transversal root canal sectioning from human extracted canines. The root canal specimens were standardized and filled with the following materials (n = 10, each group): G1: zinc phosphate (control), G2: Ketac glass-ionomer, G3: vitrebond glass-ionomer or G4: GC GL glass-ionomer. After 24 hours, the specimens were subjected to an application of 37% carbamide peroxide for 21 days, changed each 7 days and stored in an artificial pulp chamber. The specimens were then submitted to push-out bond strength testing with an electromechanical test machine (EMIC) and the failure mode in each specimen was analyzed with confocal microscopy (LEXT). Results G3 and G4 showed higher bond strengths values than the other groups (p < 0.05), and were similar to each other (p > 0.05). G1 showed the lowest bond strength value (p < 0.05). Conclusion Glass-ionomer cements showed higher bond strength values than the zinc phosphate cement, and resinmodified glass-ionomer cements presented the highest push-out values to root canal dentin (GC, GL and Vitrebond). Clinical significance Glass ionomer cements are recommended to use as cervical barrier materials before the internal dental bleaching, but its efficiency is questionable. How to cite this article Lima SNL, Venção AC, Kuga MC, Magro MG, Guiotti AM, Segalla JCM, Jordão-Basso KCF, Ricci WA, Tonetto MR, Bandéca MC. Effect of Carbamide Peroxide on the Push-out Bond Strength of Different Composition Glass-Ionomer Cement to Root Canal Dentin when used as Cervical Barrier. J Contemp Dent Pract 2015;16(12):944-949.


2020 ◽  
Vol 8 (02) ◽  
pp. 49-54
Author(s):  
Salil Mehra ◽  
Ashu K. Gupta ◽  
Bhanu Pratap Singh ◽  
Mandeep Kaur ◽  
Ashwath Kumar

Abstract Introduction The aim of the current study was to evaluate shear bond strength of resin composite bonded to Theracal LC, Biodentine, and resin-modified glass ionomer cement (RMGIC) using universal adhesive and mode of fracture. Materials and Methods A total of 50 caries-free maxillary and mandibular molars extracted were taken; occlusal cavities were prepared, mounted in acrylic blocks, and divided into five groups based on the liner used. Group 1: Biodentine liner placed into the cavity and bonding agent and resin composite applied after 12 minutes. Group 2: Biodentine liner placed into the cavity and bonding agent and resin composite applied after 14 days. Group 3: RMGIC liner placed into the cavity and bonding agent and resin composite applied immediately. Group 4: RMGIC liner placed into the cavity and bonding agent and resin composite applied after 7 days. Group 5: Theracal LC liner placed into the cavity and bonding agent and resin composite applied immediately. Each sample was bonded to resin composite using universal adhesive. Shear bond strength analysis was performed at a cross-head speed of 0.1 mm/min. Statistical Analysis  Statistical analysis was performed with one-way analysis of variance and posthoc Bonferroni test using SPSS version 22.0. Results and Conclusion Biodentine liner when bonded immediately to resin composite showed minimum shear bond strength. RMGIC when bonded to resin composite after 7 days showed maximum shear bond strength. Mode of fracture was predominantly cohesive in groups having Biodentine and Theracal LC as liner.


2010 ◽  
Vol 33 (2) ◽  
pp. 180-184 ◽  
Author(s):  
H. Y. Cheng ◽  
C. H. Chen ◽  
C. L. Li ◽  
H. H. Tsai ◽  
T. H. Chou ◽  
...  

2015 ◽  
Vol 62 (1) ◽  
pp. 7-13 ◽  
Author(s):  
Sameer Makkar ◽  
Ruchi Vashisht ◽  
Anita Kalsi ◽  
Pranav Gupta

Summary Introduction Throughout the history of dentistry, a wide variety of materials such as gold-foil, silver posts, amalgam, zinc oxide eugenol, glass ionomer cements, mineral trioxide aggregate have been used as retrograde fillings. Altered pH in periapical lesions can affect push-out bond strength of these materials. The aim of this study was to evaluate the effect of altered pH on push-out bond strength of Biodentin, Glass ionomer cement (GIC), Mineral trioxide aggregate (MTA) and Theracal. Material and Methods Forty-eight dentin slices of extracted single-rooted human teeth were sectioned and their canal portion instrumented to achieve a diameter of 1.4 mm. The specimens were then assigned into the four groups (one group for each material) with 12 samples in each group. All groups were further divided into 3 subgroups (with 4 specimens in each subgroup): acidic (butyric acid buffered at pH 6.4), neutral (phosphate buffer saline solution at pH 7.4) and alkaline (buffered potassium hydroxide at pH 8.4). Samples were incubated for 4 days at 37°C in acidic, neutral or alkaline medium. Push-out bond strength was measured using a Universal Testing Machine. The slices were examined under a stereomicroscope to determine the nature of bond failure. Results GIC showed the highest bond strength (33.33MPa) in neutral and acidic medium (26.75MPa) compared to other materials. Biodentin showed the best result in alkaline medium. Conclusion Altered pH level affected push-out bond strength of root end materials. GIC demonstrated good push-out bond strength that increased with decrease of pH whereas newer materials Biodentin and Theracal showed satisfying results in altered pH.


2013 ◽  
Vol 38 (2) ◽  
pp. 186-196 ◽  
Author(s):  
Camila Sabatini ◽  
Manthan Patel ◽  
Eric D'Silva

SUMMARY Objective To evaluate the shear bond strength (SBS) of three self-adhesive resin cements and a resin-modified glass ionomer cement (RMGIC) to different prosthodontic substrates. Materials and Methods The substrates base metal, noble metal, zirconia, ceramic, and resin composite were used for bonding with different cements (n=12). Specimens were placed in a bonding jig, which was filled with one of four cements (RelyX Unicem, Multilink Automix, Maxcem Elite, and FujiCEM Automix). Both light-polymerizing (LP) and self-polymerizing (SP) setting reactions were tested. Shear bond strength was measured at 15 minutes and 24 hours in a testing device at a test speed of 1 mm/min and expressed in MPa. A Student t-test and a one-way analysis of variance (ANOVA) were used to evaluate differences between setting reactions, between testing times, and among cements irrespective of other factors. Generalized linear regression model and Tukey tests were used for multifactorial analysis. Results Significantly higher mean SBS were demonstrated for LP mode relative to SP mode (p&lt;0.001) and for 24 hours relative to 15 minutes (p&lt;0.001). Multifactorial analysis revealed that all factors (cement, substrate, and setting reaction) and all their interactions had a significant effect on the bond strength (p&lt;0.001). Resin showed significantly higher SBS than other substrates when bonded to RelyX Unicem and Multilink Automix in LP mode (p&lt;0.05). Overall, FujiCEM demonstrated significantly lower SBS than the three self-adhesive resin cements (p&lt;0.05). Conclusions Overall, higher bond strengths were demonstrated for LP relative to SP mode, 24 hours relative to 15 minutes and self-adhesive resin cements compared to the RMGICs. Bond strengths also varied depending on the substrate, indicating that selection of luting cement should be partially dictated by the substrate and the setting reaction.


Sign in / Sign up

Export Citation Format

Share Document