scholarly journals Systematic Development of a Simultaneous Determination of Plastic Particle Identity and Adsorbed Organic Compounds by Thermodesorption–Pyrolysis GC/MS (TD-Pyr-GC/MS)

Molecules ◽  
2020 ◽  
Vol 25 (21) ◽  
pp. 4985
Author(s):  
Julia Reichel ◽  
Johanna Graßmann ◽  
Thomas Letzel ◽  
Jörg E. Drewes

Micro-, submicro- and nanoplastic particles are increasingly regarded as vectors for trace organic chemicals. In order to determine adsorbed trace organic chemicals on polymers, it has usually been necessary to carry out complex extraction steps. With the help of a newly designed thermal desorption pyrolysis gas chromatography mass spectrometry (TD-Pyr-GC/MS) method, it is possible to identify adsorbed trace organic chemicals on micro-, submicro- and nanoparticles as well as the particle short chain polymers in one analytical setup without any transfers. This ensures a high sample throughput for the qualitative analysis of trace substances and polymer type. Since the measuring time per sample is only 2 h, a high sample throughput is possible. It is one of the few analytical methods which can be used also for the investigation of nanoplastic particles. Initially adsorbed substances are desorbed from the particle by thermal desorption (TD); subsequently, the polymer is fragmented by pyrolysis (PYR). Both particle treatment techniques are directly coupled with the same GC-MS system analyzing desorbed molecules and pyrolysis products, respectively. In this study, we developed a systematic and optimized method for this application. For method development, the trace organic chemicals phenanthrene, α-cypermethrin and triclosan were tested on reference polymers polystyrene (PS), polymethyl methacrylate (PMMA) and polyethylene (PE). Well-defined particle fractions were used, including polystyrene (sub)micro- (41 and 40 µm) and nanoparticles (78 nm) as well as 48-µm sized PE and PMMA particles, respectively. The sorption of phenanthrene (PMMA << PS 40 µm < 41 µm < PE < PS 78 nm) and α-cypermethrin (PS 41 µm < PS 40 µm < PE < PMMA < PS 78 nm) to the particles was strongly polymer-dependent. Triclosan adsorbed only on PE and on the nanoparticles of PS (PE < PS78).

2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Xianglu Peng ◽  
Melanie Brown ◽  
Paul Bowdler ◽  
Kevin C. Honeychurch

An extraction-free method requiring microliter (μL) volumes has been developed for the determination of caffeine in beverages. Using a pyrolysis-gas chromatography mass spectrometry system, the conditions required for the direct thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) determination of caffeine were optimised. A 5 μL aliquot was introduced to the thermal desorption unit, dried, and thermally desorbed to the GC/MS. The response was linear over the range 10 to 500 μg/mL (R2 = 0.996). The theoretical limit of detection (3 σ) was 0.456 μg/mL. No interferences were recorded from endogenous beverage components or from commonly occurring drugs, such as nicotine, ibuprofen, and paracetamol. Replicate caffeine determinations on fortified latte style white coffee and Pepsi Max® gave mean recoveries of 93.4% (%CV = 4.1%) and 95.0% (%CV = 0.98%), respectively. Good agreement was also obtained with the stated values of caffeine for an energy drink and for Coca-Cola®. These data suggest that the method holds promise for the determination of caffeine in such samples.


Chemosphere ◽  
2015 ◽  
Vol 127 ◽  
pp. 136-142 ◽  
Author(s):  
Julia Regnery ◽  
Jessica Barringer ◽  
Alexandre D. Wing ◽  
Christiane Hoppe-Jones ◽  
Jennifer Teerlink ◽  
...  

1999 ◽  
Vol 33 (10) ◽  
pp. 1513-1523 ◽  
Author(s):  
Don T. Waite ◽  
Allan J. Cessna ◽  
Narine P. Gurprasad ◽  
James Banner

Processes ◽  
2021 ◽  
Vol 9 (9) ◽  
pp. 1571
Author(s):  
Patricia Jové ◽  
Marina Vives-Mestres ◽  
Raquel De Nadal ◽  
Maria Verdum

Compounds 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and pentachloroanisole (PCA), 2-methylisoborneol (2MIB) and geosmin (GSM) have been reported as being responsible for cork and wine taint. A sustainable method based on thermal desorption-gas chromatography–mass spectrometry (TD-GC/MS) has been developed and optimized, taking into account desorption parameters and chromatographic and mass spectrometric conditions. The combination of parameters that jointly maximized the compound detection was as follows: desorption temperature at 300 °C, desorption time at 30 min, cryo-temperature at 20 °C and trap high temperature at 305 °C. The proposed methodology showed a good linearity (R ≤ 0.994) within the tested range (from 0.1 to 2 ng) for all target compounds. The precision expressed as repeatability and reproducibility was RSD < 10% in both. The limits of quantification ranged from 0.05 to 0.1 ng. The developed methodology and the sampling rates (R-values) of all targeted compounds (from 0.013 to 0.071 m3 h−1) were applied to the air analysis of two wineries. The results showed that the developed methodology is a sustainable and useful tool for the determination of these compounds in air.


Sign in / Sign up

Export Citation Format

Share Document