scholarly journals Low Cost Micro Milling Machine for Prototyping Plastic Microfluidic Devices

Proceedings ◽  
2018 ◽  
Vol 2 (13) ◽  
pp. 707 ◽  
Author(s):  
Md Mubarak Hossain ◽  
Tanzilur Rahman

Micro-milling is one of the commonly used methods of fabrication of microfluidic devices necessary for cell biological research and application. Commercial micro-milling machines are expensive, and researchers in developing countries can’t afford them. Here, we report the design and the development of a low-cost (<130 USD) micro milling machine and asses the prototyping capabilities of microfeatures in plastic materials. We demonstrate that the developed machine can be used in fabricating the plastic based microfluidic device.

Micromachines ◽  
2018 ◽  
Vol 9 (8) ◽  
pp. 387
Author(s):  
Carlos Toshiyuki Matsumi ◽  
Wilson José da Silva ◽  
Fábio Kurt Schneider ◽  
Joaquim Miguel Maia ◽  
Rigoberto E. M. Morales ◽  
...  

Microbubbles have various applications including their use as carrier agents for localized delivery of genes and drugs and in medical diagnostic imagery. Various techniques are used for the production of monodisperse microbubbles including the Gyratory, the coaxial electro-hydrodynamic atomization (CEHDA), the sonication methods, and the use of microfluidic devices. Some of these techniques require safety procedures during the application of intense electric fields (e.g., CEHDA) or soft lithography equipment for the production of microfluidic devices. This study presents a hybrid manufacturing process using micropipettes and 3D printing for the construction of a T-Junction microfluidic device resulting in simple and low cost generation of monodisperse microbubbles. In this work, microbubbles with an average size of 16.6 to 57.7 μm and a polydispersity index (PDI) between 0.47% and 1.06% were generated. When the device is used at higher bubble production rate, the average diameter was 42.8 μm with increased PDI of 3.13%. In addition, a second-order polynomial characteristic curve useful to estimate micropipette internal diameter necessary to generate a desired microbubble size is presented and a linear relationship between the ratio of gaseous and liquid phases flows and the ratio of microbubble and micropipette diameters (i.e., Qg/Ql and Db/Dp) was found.


Micromachines ◽  
2018 ◽  
Vol 9 (9) ◽  
pp. 461 ◽  
Author(s):  
Hoang-Tuan Nguyen ◽  
Ha Thach ◽  
Emmanuel Roy ◽  
Khon Huynh ◽  
Cecile Perrault

Microfluidics are expected to revolutionize the healthcare industry especially in developing countries since it would bring portable, easy-to-use, self-contained diagnostic devices to places with limited access to healthcare. To date, however, microfluidics has not yet been able to live up to these expectations. One non-negligible factor can be attributed to inaccessible prototyping methods for researchers in low-resource settings who are unable to afford expensive equipment and/or obtain critical reagents and, therefore, unable to engage and contribute to microfluidics research. In this paper, we present methods to create microfluidic devices that reduce initial costs from hundreds of thousands of dollars to about $6000 by using readily accessible consumables and inexpensive equipment. By including the scientific community most embedded and aware of the requirements of healthcare in developing countries, microfluidics will be able to increase its reach in the research community and be better informed to provide relevant solutions to global healthcare challenges.


Author(s):  
Travis S. Emery ◽  
Anna Jensen ◽  
Koby Kubrin ◽  
Michael G. Schrlau

Three-dimensional (3D) printing is a novel technology whose versatility allows it to be implemented in a multitude of applications. Common fabrication techniques implemented to create microfluidic devices, such as photolithography, wet etching, etc., can often times be time consuming, costly, and make it difficult to integrate external components. 3D printing provides a quick and low-cost technique that can be used to fabricate microfluidic devices in a range of intricate geometries. External components, such as nanoporous membranes, can additionally be easily integrated with minimal impact to the component. Here in, low-cost 3D printing has been implemented to create a microfluidic device to enhance understanding of flow through carbon nanotube (CNT) arrays manufactured for gene transfection applications. CNTs are an essential component of nanofluidic research due to their unique mechanical and physical properties. CNT arrays allow for parallel processing however, they are difficult to construct and highly prone to fracture. As a means of aiding in the nanotube arrays’ resilience to fracture and facilitating its integration into fluidic systems, a 3D printed microfluidic device has been constructed around these arrays. Doing so greatly enhances the robustness of the system and additionally allows for the nanotube array to be implemented for a variety of purposes. To broaden their range of application, the devices were designed to allow for multiple isolated inlet flows to the arrays. Utilizing this multiple inlet design permits distinct fluids to enter the array disjointedly. These 3D printed devices were in turn implemented to visualize flow through nanotube arrays. The focus of this report though, is on the design and fabrication of the 3D printed devices. SEM imaging of the completed device shows that the nanotube array remains intact after the printing process and the nanotubes, even those within close proximity to the printing material, remain unobstructed. Printing on top of the nanotube arrays displayed effective adhesion to the surface thus preventing leakage at these interfaces.


Author(s):  
Peter D. Dunning ◽  
Pierre E. Sullivan ◽  
Michael J. Schertzer

The ability to remove unbound biological material from a reaction site has applications in many biological protocols, such as those used to detect pathogens and biomarkers. One specific application where washing is critical is the Enzyme-Linked ImmunoSorbent Assay (ELISA). This protocol requires multiple washing steps to remove multiple reagents from a reaction site. Previous work has suggested that a passive mechanical comb filter can be used to wash particles in digital microfluidic devices. A method for the characterization of passive mechanical filtration of particles in Digital MicroFluidic (DMF) devices is presented in this work. In recent years there has been increased development of Lab-On-A-Chip (LOAC) devices for the automation and miniaturization of biological protocols. One platform for further research is in digital microfluidics. A digital microfluidic device can control the movement of pico-to nanoliter droplets of fluid using electrical signals without the use of pumps, valves, and channels. As such, fluidic pathways are not hardwired and the path of each droplet can be easily reconfigured. This is advantageous in biological protocols requiring the use of multiple reagents. Fabrication of these devices is relatively straight forward, since fluid manipulation is possible without the use of complex components. This work presents a method to characterize the performance of a digital microfluidic device using passive mechanical supernatant dilution via image analysis using a low cost vision system. The primary metric for performance of the device is particle retention after multiple passes through the filter. Repeatability of the process will be examined by characterizing performance of multiple devices using the same filter geometry. Qualitative data on repeatability and effectiveness of the dilution technique will also be attained by observing the ease with which the droplet disengages from the filter and by measuring the quantity of fluid trapped on the filter after each filtration step.


2021 ◽  
Author(s):  
Christine Poon ◽  
Albert Fahrenbach

3D printing and makerspace technologies are increasingly explored as alternative techniques to soft lithography for making microfluidic devices, and for their potential to segue towards scalable commercial fabrication. Here we considered the optimal application of current benchtop 3D printing for microfluidic device fabrication through the lens of lean manufacturing and present a straightforward but robust rapid prototyped moulding system that enables easy estimation of more precise quantities of polydimethylsiloxane (PDMS) required per device to reduce waste and importantly, making devices with better defined depths and volumes for (i) modelling gas exchange and (ii) fabrication consistency as required for quality-controlled production. We demonstrate that this low-cost moulding step can enable a 40 – 300% reduction in the amount of PDMS required for making individual devices compared to the established method of curing approximately 30 grams of PDMS prepolymer overlaid on a 4” silicon wafer master in a standard plastic petri dish. Other process optimisation techniques were also investigated and are recommended as readily implementable changes to current laboratory and foundry-level microfluidic device fabrication protocols for making devices either out of PDMS or other elastomers. Simple calculators are provided as a step towards more streamlined, software controlled and automated design-to-fabrication workflows for both custom and scalable lean manufacturing of microfluidic devices.


Micromachines ◽  
2020 ◽  
Vol 11 (9) ◽  
pp. 872
Author(s):  
Francesco Costa ◽  
Luigi Falzetti ◽  
Nicola Baldini ◽  
Sofia Avnet

Microfluidic principles have been widely applied for more than 30 years to solve biological and micro-electromechanical problems. Despite the numerous advantages, microfluidic devices are difficult to manage as their handling comes with several technical challenges. We developed a new portable tool, the microfluidic trainer (MT), that assesses the operator handling skills and that may be used for maintaining or improving the ability to inject fluid in the inlet of microfluidic devices for in vitro cell culture applications. After several tests, we optimized the MT tester cell to reproduce the real technical challenges of a microfluidic device. In addition to an exercise path, we included an overfilling indicator and a correct infilling indicator at the inlet (control path). We manufactured the MT by engraving a 3 mm-high sheet of methacrylate with 60W CO2 laser plotter to create multiple capillary paths. We validated the device by enrolling 21 volunteers (median age 33) to fill both the MT and a commercial microfluidic device. The success rate obtained with MT significantly correlated with those of a commercial microfluidic culture plate, and its 30 min-continuous use for three times significantly improved the performance. Overall, our data demonstrate that MT is a valid assessment tool of individual performances in using microfluidic devices and may represent a low-cost solution to training, improve or warm up microfluidic handling skills.


2005 ◽  
Vol 897 ◽  
Author(s):  
Gerardo Antonio Diaz-Quijada ◽  
Regis Peytavi ◽  
André Nantel ◽  
Emmanuel Roy ◽  
Michel G. Bergeron ◽  
...  

AbstractMicroarrays have become one of the most convenient tools for high throughput screening, supporting major advances in genomics and proteomics. Other important applications can be found in medical diagnostics, detection of biothreats, drug discovery, etc. Integration of microarrays with microfluidic devices can be highly advantageous in terms of portability, shorter analysis time and lower consumption of expensive biological analytes. Since fabrication of microfluidic devices using traditional materials such as glass is rather expensive, there is a high interest in employing polymeric materials as a low cost alternative that is suitable for mass production. A number of commercially available plastic materials were reviewed for this purpose and poly(methylmethacrylate) and Zeonor™ 1060R were identified as promising candidates, for which methods for surface modification and covalent immobilization of DNA oligonucleotide were developed. In addition, we present proof-of-concept plastic-based microarrays with and without integration with microfluidics.


Author(s):  
Xiaohong Lu ◽  
Furui Wang ◽  
Kun Yang ◽  
Yixuan Feng ◽  
Steven Y. Liang

Abstract Nowadays, the measurement of micro-milling forces is mainly achieved by a force transducer. However, the frequency of force signal is high, due to the spindle super-speed, which leads to failure of the micro-milling forces measurement by using common force sensors. Additionally, micro force sensors with high-resolution and high sampling frequency are preferred, but they are often expensive. To determine the average micro-milling force with low cost and high precision, we propose an indirect method, by determining the power of the main transmission system of a micro-milling machine. First, the measurement system for the micro-milling machine tool power was introduced, and various sensors were used to measure the current and voltage respectively. Then, a high-frequency sampling system based on the Labview was developed to process the current and voltage signals, and to obtain the power data of the main transmission system. Through this process, the indirect measurement of micro-milling forces was achieved. Finally, we validated the effectiveness of the developed on-line measurement system and the proposed indirect measurement method for average micro-milling force by using experiments. The proposed method is practical and low-cost, and it can lay the foundation for further research on cutting energy consumption.


Lab on a Chip ◽  
2015 ◽  
Vol 15 (14) ◽  
pp. 3086-3094 ◽  
Author(s):  
Juhong Chen ◽  
Yiliang Zhou ◽  
Danhui Wang ◽  
Fei He ◽  
Vincent M. Rotello ◽  
...  

A low-cost and rapid method is developed to fabricate a flexible microfluidic device containing electrowetting valves and electrochemical transduction.


Sign in / Sign up

Export Citation Format

Share Document