digital microfluidics
Recently Published Documents


TOTAL DOCUMENTS

379
(FIVE YEARS 107)

H-INDEX

41
(FIVE YEARS 9)

Lab on a Chip ◽  
2022 ◽  
Author(s):  
Mingzhong Li ◽  
Liang Wan ◽  
Man-Kay Law ◽  
Li Meng ◽  
Yanwei Jia ◽  
...  

Proposed high-accuracy one-shot melting curve analysis on a digital microfluidics platform, enabling KRAS gene discrimination with single-nucleotide mutations in 3 seconds.


Lab on a Chip ◽  
2022 ◽  
Author(s):  
Donghao Li ◽  
Xinyu Liu ◽  
Yujuan Chai ◽  
Jieying Shan ◽  
Yihan Xie ◽  
...  

The monitoring of coagulation function has great implications in many clinical settings. However, existing coagulation assays are simplex, sample-consuming, and slow in turnaround, making them less suitable for point-of-care testing....


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Christoph Doering ◽  
Johannes Strassner ◽  
Henning Fouckhardt

Meanwhile, electrowetting-on-dielectric (EWOD) is a well-known phenomenon, even often exploited in active micro-optics to change the curvature of microdroplet lenses or in analytical chemistry with digital microfluidics (DMF, lab on a chip 2.0) to move/actuate microdroplets. Optoelectrowetting (OEW) can bring more flexibility to DMF because in OEW, the operating point of the lab chip is locally controlled by a beam of light, usually impinging onto the chip perpendicularly. As opposed to pure EWOD, for OEW, none of the electrodes has to be structured, which makes the chip design and production technology simpler; the path of any actuated droplet is determined by the movement of the light spot. However, for applications in analytical chemistry, it would be helpful if the space both below as well as that above the lab chip were not obstructed by any optical components and light sources. Here, we report on the possibility to actuate droplets by laser light beams, which traverse the setup parallel to the chip surface and inside the OEW layer sequence. Since microdroplets are grabbed by this surface-parallel, nondiverging, and nonexpanded light beam, we call this principle “light line OEW” (LL-OEW).


2021 ◽  
pp. 2101251
Author(s):  
Sebastian von der Ecken ◽  
Alexandros A. Sklavounos ◽  
Aaron R. Wheeler

Micromachines ◽  
2021 ◽  
Vol 12 (11) ◽  
pp. 1423
Author(s):  
Zhen Gu ◽  
Jing-Jing Luo ◽  
Le-Wei Ding ◽  
Bing-Yong Yan ◽  
Jia-Le Zhou ◽  
...  

Digital microfluidic (DMF) has been a unique tool for manipulating micro-droplets with high flexibility and accuracy. To extend the application of DMF for automatic and in-site detection, it is promising to introduce colorimetric sensing based on gold nanoparticles (AuNPs), which have advantages including high sensitivity, label-free, biocompatibility, and easy surface modification. However, there is still a lack of studies for investigating the movement and stability of AuNPs for in-site detection on the electrowetting-based digital microfluidics. Herein, to demonstrate the ability of DMF for colorimetric sensing with AuNPs, we investigated the electrowetting property of the AuNPs droplets on the hydrophobic interface of the DMF chip and examined the stability of the AuNPs on DMF as well as the influence of evaporation to the colorimetric sensing. As a result, we found that the electrowetting of AuNPs fits to a modified Young–Lippmann equation, which suggests that a higher voltage is required to actuate AuNPs droplets compared with actuating water droplets. Moreover, the stability of AuNPs was maintained during the processing of electrowetting. We also proved that the evaporation of droplets has a limited influence on the detections that last several minutes. Finally, a model experiment for the detection of Hg2+ was carried out with similar results to the detections in bulk solution. The proposed method can be further extended to a wide range of AuNPs-based detection for label-free, automatic, and low-cost detection of small molecules, biomarkers, and metal ions.


Micromachines ◽  
2021 ◽  
Vol 12 (11) ◽  
pp. 1385
Author(s):  
Ting-Chia Chu ◽  
Yen-Wen Lu

A digital microfluidic modular interface (chip-to-chip interface) which possesses an electrode with an orifice to vertically transport core–shell droplets is presented. The electrodes were geometrically designed to promote droplet deformation and suspension. The droplets were then applied with an electrical potential for insertion into and passage through the orifice. The concepts were tested with three types of droplets at the volume of 0.75~1.5 μL, which is usually difficult to transfer through an orifice. The integration of electrowetting on dielectric (EWOD) with paper-based microfluidics was demonstrated: the droplet could be transported within 10 s. More importantly, most of the core droplet (~97%) was extracted and passed through with only minimal shell droplets accompanying it.


ACS Omega ◽  
2021 ◽  
Author(s):  
Yuguang Liu ◽  
Patricio Jeraldo ◽  
Helena Mendes-Soares ◽  
Thao Masters ◽  
Abigail E. Asangba ◽  
...  

Micromachines ◽  
2021 ◽  
Vol 12 (9) ◽  
pp. 1065
Author(s):  
Nicholas Grant ◽  
Brian Geiss ◽  
Stuart Field ◽  
August Demann ◽  
Thomas W. Chen

Microfluidics offer many advantages to Point of Care (POC) devices through lower reagent use and smaller size. Additionally, POC devices offer the unique potential to conduct tests outside of the laboratory. In particular, Electro-wetting on Dielectric (EWOD) microfluidics has been shown to be an effective way to move and mix liquids enabling many PoC devices. However, much of the research surrounding these microfluidic systems are focused on a single aspect of the system capability, such as droplet control or a specific new application at the device level using the EWOD technology. Often in these experiments the supporting systems required for operation are bench top equipment such as function generators, power supplies, and personal computers. Although various aspects of how an EWOD device is capable of moving and mixing droplets have been demonstrated at various levels, a complete self-contained and portable lab-on-a-chip system based on the EWOD technology has not been well demonstrated. For instance, EWOD systems tend to use high voltage alternating current (AC) signals to actuate electrodes, but little consideration is given to circuitry size or power consumption of such components to make the entire system portable. This paper demonstrates the feasibility of integrating all supporting hardware and software to correctly operate an EWOD device in a completely self-contained and battery-powered handheld unit. We present results that demonstrate a complete sample preparation flow for deoxyribonucleic acid (DNA) extraction and isolation. The device was designed to be a field deployable, hand-held platform capable of performing many other sample preparation tasks automatically. Liquids are transported using EWOD and controlled via a programmable microprocessor. The programmable nature of the device allows it to be configured for a variety of tests for different applications. Many considerations were given towards power consumption, size, and system complexity which make it ideal for use in a mobile environment. The results presented in this paper show a promising step forward to the portable capability of microfluidic devices based on the EWOD technology.


2021 ◽  
Vol 9 ◽  
Author(s):  
Beomseok Cha ◽  
Woohyuk Kim ◽  
Giseong Yoon ◽  
Hyunwoo Jeon ◽  
Jinsoo Park

Digital microfluidics based on sessile droplets has emerged as a promising technology for various applications including biochemical assays, clinical diagnostics, and drug screening. Digital microfluidic platforms provide an isolated microenvironment to prevent cross-contamination and require reduced sample volume. Despite these advantages, the droplet-based technology has the inherent limitation of the quiescent flow conditions at low Reynolds number, which causes mixing samples confined within the droplets to be challenging. Recently, solutal Marangoni flows induced by volatile liquids have been utilized for sessile droplet mixing to address the above-mentioned limitation. The volatile liquid vaporized near a sessile droplet induces a surface tension gradient throughout the droplet interface, leading to vortical flows inside a droplet. This Marangoni flow-based droplet mixing method does not require an external energy source and is easy to operate. However, this passive method requires a comparably long time of a few tens of seconds for complete mixing since it depends on the natural evaporation of the volatile liquid. Here, we propose an improved ultrasound-induced heating method based on a nature-inspired ultrasound-absorbing layer and apply it to enhance solutal Marangoni effect. The heater consists of an interdigital transducer deposited on a piezoelectric substrate and a silver nanowire-polydimethylsiloxane composite as an ultrasound-absorbing layer. When the transducer is electrically actuated, surface acoustic waves are produced and immediately absorbed in the composite layer by viscoelastic wave attenuation. The conversion from acoustic to thermal energy occurs, leading to rapid heating. The heating-mediated enhanced vaporization of a volatile liquid accelerates the solutal Marangoni flows and thus enables mixing high-viscosity droplets, which is unachievable by the passive solutal Marangoni effect. We theoretically and experimentally investigated the enhanced Marangoni flow and confirmed that rapid droplet mixing can be achieved within a few seconds. The proposed heater-embedded sessile droplet mixing platform can be fabricated in small size and easily integrated with other digital microfluidic platforms. Therefore, we expect that the proposed sample mixing method can be utilized for various applications in digital microfluidics and contribute to the advancements in the medical and biochemical fields.


Sign in / Sign up

Export Citation Format

Share Document