scholarly journals Measurement of Atmospheric Dimethyl Sulfide with a Distributed Feedback Interband Cascade Laser

Sensors ◽  
2018 ◽  
Vol 18 (10) ◽  
pp. 3216 ◽  
Author(s):  
Shuanke Wang ◽  
Zhenhui Du ◽  
Liming Yuan ◽  
Yiwen Ma ◽  
Xiaoyu Wang ◽  
...  

This paper presents a mid-infrared dimethyl sulfide (CH3SCH3, DMS) sensor based on tunable laser absorption spectroscopy with a distributed feedback interband cascade laser to measure DMS in the atmosphere. Different from previous work, in which only DMS was tested and under pure nitrogen conditions, we measured DMS mixed by common air to establish the actual atmospheric measurement environment. Moreover, we used tunable laser absorption spectroscopy with spectral fitting to enable multi-species (i.e., DMS, CH4, and H2O) measurement simultaneously. Meanwhile, we used empirical mode decomposition and greatly reduced the interference of optical fringes and noise. The sensor performances were evaluated with atmospheric mixture in laboratory conditions. The sensor’s measurement uncertainties of DMS, CH4, and H2O were as low as 80 ppb, 20 ppb, and 0.01% with an integration time 1 s, respectively. The sensor possessed a very low detection limit of 9.6 ppb with an integration time of 164 s for DMS, corresponding to an absorbance of 7.4 × 10−6, which showed a good anti-interference ability and stable performance after optical interference removal. We demonstrated that the sensor can be used for DMS measurement, as well as multi-species atmospheric measurements of DMS, H2O, and CH4 simultaneously.

2013 ◽  
Author(s):  
M. von Edlinger ◽  
J. Scheuermann ◽  
L. Nähle ◽  
C. Zimmermann ◽  
L. Hildebrandt ◽  
...  

Micromachines ◽  
2018 ◽  
Vol 9 (10) ◽  
pp. 530 ◽  
Author(s):  
Ye Mu ◽  
Tianli Hu ◽  
He Gong ◽  
Ruiwen Ni ◽  
Shijun Li

In this study, tunable diode laser absorption spectroscopy (TDLAS) combined with wavelength modulation spectroscopy (WMS) was used to develop a trace C2H2 sensor based on the principle of gas absorption spectroscopy. The core of this sensor is an interband cascade laser that releases wavelength locks to the best absorption line of C2H2 at 3305 cm−1 (3026 nm) using a driving current and a working temperature control. As the detected result was influenced by 1/f noise caused by the laser or external environmental factors, the TDLAS-WMS technology was used to suppress the 1/f noise effectively, to obtain a better minimum detection limit (MDL) performance. The experimental results using C2H2 gas with five different concentrations show a good linear relationship between the peak value of the second harmonic signal and the gas concentration, with a linearity of 0.9987 and detection accuracy of 0.4%. In total, 1 ppmv of C2H2 gas sample was used for a 2 h observation experiment. The data show that the MDL is low as 1 ppbv at an integration time of 63 s. In addition, the sensor can be realized by changing the wavelength of the laser to detect a variety of gases, which shows the flexibility and practicability of the proposed sensor.


Sign in / Sign up

Export Citation Format

Share Document