scholarly journals A Reactive Power Compensation Strategy for Voltage Stability Challenges in the Korean Power System with Dynamic Loads

2019 ◽  
Vol 11 (2) ◽  
pp. 326 ◽  
Author(s):  
Yunhwan Lee ◽  
Hwachang Song

This paper describes a methodology and specifics for technical studies on fault-induced delayed voltage recovery (FIDVR) mitigation to ensure power system reliability. Optimal locations of the dynamic volts-ampere-reactive (VAR) sources are determined for addressing the FIDVR issues in the voltage stability analysis and assessment methodology. We propose a voltage stability analysis method for planning dynamic VAR sources for bettering electric power transmission systems under contingency conditions. A time-domain dynamic simulation is performed to assess short-term voltage stability. While conducting dynamic simulations, sensitivity analysis is performed to assess the need for dynamic VAR sources. This study focuses on a reactive power compensation strategy to determine system voltage recovery performance by optimal flexible alternating current transmission system (FACTS) placement in a metropolitan region. The objective of this study is to determine the optimal installation of dynamic VAR sources while satisfying the requirements of voltage stability margin and transient voltage dip under a set of criteria. New insights are presented on the effect of FACTS controls on the reactive power compensation, which supports voltage recovery. The main features of the proposed method are (i) the development based on a load model for FIDVR, (ii) the use of sensitivity analysis of the network to the variations of the IM load, (iii) the establishment of the control function and compensation strategy to maintain the voltage of system within criteria limits, and (iv) the use of the sensitivity analysis based on branch parameterization for unsolvable cases. Case studies on the Korean power system validated the performance of the proposed strategy, showing that it effectively installed FACTS under contingency scenarios.

2013 ◽  
Vol 694-697 ◽  
pp. 846-849
Author(s):  
Jian Yuan Xu ◽  
Wei Fu Qi ◽  
Yun Teng

This paper mainly studies wind power fluctuations how to affect voltage stability after the wind power grid integration, and reactive power compensation equipment on improving effect. In certain parts of the wind farm, for example, firstly, analyzing the wind farm reactive power problems. Then introduce the reactive power compensation equipment that used in the wind farm. Finally, with PSCAD software, making a simulation analysis about the influence on the power grid voltage according to adopting the different reactive power compensation devices or not.


2020 ◽  
Vol 39 (1) ◽  
pp. 228-237
Author(s):  
I.B. Anichebe ◽  
A.O. Ekwue

Frequent blackouts and unstable supply of electricity show that the  voltage instability problem has been one of the major challenges facing the power system network in Nigeria. This study investigates the voltage stability analysis of the Nigerian power network in the presence of renewable energy sources; FACTS device is used as a voltage controller. A 330kV, 28-bus power system network was studied using the PSS/E software-based Newton-Raphson load-flow technique. The results show that 10 out of the 28 buses had voltages lying below the statutory limit of 0.95 ≤ 1.05 p.u. The application of STATCOM and DFIG devices on two of the weakest buses restored the voltages to acceptable statutory limits. The total active and reactive power losses were reduced to 18.76% and 18.82% respectively. Keywords: Voltage stability analysis; Integration of renewable energy sources; FACTS controllers, Reactive Power, Power Flow.


2011 ◽  
Vol 317-319 ◽  
pp. 1778-1782 ◽  
Author(s):  
You Jie Ma ◽  
Jin Hua Liu ◽  
Xue Song Zhou ◽  
Ji Li

As a new dynamic reactive compensation devices, static synchronous compensator (STATCOM) has better reactive power compensation effect such as small in size, capacity, continuous adjusting, fast response and economic performance compared with SVC. It is suitable to be used in large-scale wind farm to improve the voltage stability of wind power system. With the help of ideas and methods in conventional electric power system to calculate the two-dimensional parameter bifurcation boundary, the node voltage two-dimensional saddle-node bifurcation boundary of wind power system was calculated by using wind farm active power inject(Pin ),STATCOM parameters KMdc and Vrefdc as bifurcation control parameters. And on the basis of this analysis, the laws of wind power system voltage stability affected by active power and STATCOM parameters were obtained.


2021 ◽  
Vol 2021 ◽  
pp. 1-16
Author(s):  
Ombuki Mogaka ◽  
Roy Orenge ◽  
Julius Ndirangu

In recent years, the Kenyan Power Network has witnessed large growths in load demand. Although the increased load demand has somewhat been matched with an increase in transmission and generation capacity, the rate of expansion has not been matched with the rate of increase in load demand due to economic, environmental, and geographical constraints. This has led to the system being prone to instability since it is being operated under stressed conditions. In the recent past, several studies have been carried out on voltage stability analysis and improvement using various conventional methods. However, conventional methods have various limitations in their utilization for voltage stability analysis. One solution to overcome these limitations is to employ a combination of one or more methods so as to get more information and greater degree of accuracy in voltage stability studies. In this paper, a methodology is proposed involving the combination of QV modal analysis, sensitivity analysis (VQ) and power-voltage curves in assessing the static voltage stability analysis taking a case study of the Kenyan Power Network. V-Q sensitivity analysis and QV modal analysis have been used to identify the load regions most susceptible to voltage instability and the corresponding weak buses in the network for various V-Q responses. Reactive power loss sensitivities for branches in the network have been used to determine the critical (weak) lines in the network. Loading margins (LM) and voltage stability margins (VSM) have then been used to determine the proximity to voltage collapse of the voltage weak buses identified by QV modal analysis. The effect of tripping one the critical lines on the voltage weak buses is also investigated. The current high voltage power network under the average peak loading conditions during the year 2019 is considered for the study. The paper also reviews existing voltage stability analysis methods and their limitations.


2013 ◽  
Vol 756-759 ◽  
pp. 4171-4174 ◽  
Author(s):  
Xiao Ming Wang ◽  
Xing Xing Mu

With the Asynchronous wind generators as research object, this paper analyzes the problems of the voltage stability and the generation mechanism of the reactive power compensation during the wind farms connected operation. For paralleling capacitor bank has shown obvious defects, therefore this paper employs dynamic reactive power compensation to improve reactive characteristics of grid-connected wind farms. With the influences of different wind disturbances and grid faults on wind farms, wind farm model is set up and dynamic reactive power compensation system and wind speeds are built in the Matlab/Simulink software, The simulation result shows that they can provide reactive power compensation to ensure the voltage stability of the wind farms. But STATCOM needs less reactive compensation capacity to make sure the voltage and active power approaching steady state before the faults more quickly, Therefore STATCOM is more suitable for wind farms connected dynamic reactive power compensation.