scholarly journals Assessment of Indoor Environmental Quality for Retrofitting Classrooms with An Egg-Crate Shading Device in A Hot Climate

2019 ◽  
Vol 11 (4) ◽  
pp. 1078 ◽  
Author(s):  
Carmen Calama-González ◽  
Rafael Suárez ◽  
Ángel León-Rodríguez ◽  
Simone Ferrari

In the Mediterranean climate, a large number of educational buildings suffer from discomfort due mostly to energy-deficient thermal envelopes and a lack of cooling systems. Impending climate change is expected to worsen overheating in classrooms, especially during heatwave periods. Therefore, the protection of window openings to reduce incident solar radiation while maintaining adequate indoor environmental quality must be considered a necessary key focus. The main objective of this research is to assess the influence of an egg-crate shading device on the indoor environmental quality of a classroom in Southern Spain. To do so, two classrooms—with and without this shading device—were simultaneously monitored over a whole year. The implementation of an egg-crate shading device allowed for a significant reduction of the incident solar radiation, both in summer and mid-season (around 45–50%), which objectively slightly conditioned indoor operative temperatures. Given the noticeable influence of the user patterns observed, indoor illuminance was also improved, as the rolling shutters tended to be opened at higher aperture levels.

Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2790 ◽  
Author(s):  
Carmen Calama-González ◽  
Rafael Suárez ◽  
Ángel León-Rodríguez

Most educational buildings in southern Spain do not meet current energy requirements as weak thermal envelopes and the lack of cooling systems lead to severe discomfort in classrooms, especially when temperatures are above 30 °C. Given that global warming is expected to worsen this situation in coming decades, one of the first steps to be taken is to protect window openings from high levels of solar radiation by adding shading devices to reduce indoor temperatures and improve visual comfort. The aim of this research is to evaluate the reduction in thermal and lighting consumption in a classroom where a solar protection system in the form of an egg-crate shading device was installed. Two classrooms—one with an egg-crate device and another with no shading system—were monitored and compared for a whole year. The use of an egg-crate device in these classrooms reduced indoor operative temperatures during warmer periods while also improving indoor natural illuminance levels. Moreover, annual electric air conditioning consumption decreased by approximately 20%, with a 50% reduction in electric lighting consumption. These savings in electricity were largely conditioned by the use patterns observed in these ambient systems.


2016 ◽  
Vol 11 (10) ◽  
pp. 492-496 ◽  
Author(s):  
Yufan Zhang ◽  
Peter Barrett ◽  
Fay Davies ◽  
Lucinda Barrett

2015 ◽  
Vol 75 (5) ◽  
Author(s):  
Ang Qiu Mei ◽  
Md Azree Othuman Mydin

This study was done to investigate the relationship between indoor environmental quality and prevalence of Sick Building Syndrome in six small offices inPenangIsland. Indoor environmental quality measurement was conducted according to relevant standards. There are totally Sixty workers were selected to participate in an electronic questionnaire survey. Questionnaire was used to record the comfort level of respondents in the case studies and level of sick building syndrome faced by respondents. Through indoor environmental quality measurement, it is found that most of the offices facing the lighting and noise problem. The result from the questionnaire shows that in overall, the occupants satisfy with their working environment in term of indoor environmental quality although the result also shows the opinions of occupants on dissatisfaction on certain indoor environmental parameter according to case study. The study also found that most of the occupants feel drowsy and fatigue when they work within the offices. Besides, due to the difference of the indoor environmental quality of the buildings, the occupants are suffered from different symptoms of the sick building syndrome.


Author(s):  
Ibrahim Al-Sulaihi ◽  
Khalid Al-Gahtani ◽  
Abdullah Alsugair ◽  
Ibrahim Tijani

Author(s):  
Ludmila Meciarova ◽  
Silvia Vilcekova ◽  
Eva Kridlova Burdova ◽  
Ilija Zoran Apostoloski ◽  
Danica Kosicanova

Decent quality of indoor air is important for health and wellbeing of building users. We live, work and study in indoors of various types of buildings. Often people are exposed to pollutants at higher concentrations than these that occur out-doors. Continual investigation of indoor air quality is needed for ensuring comfort and healthy environment. Measuring and analysis of occurrence of physical, chemical and biological factors is the first step for suggestion of optimization measures. Inside school buildings there are often inadequate indoor climate conditions such as thermal comfort parame-ters or ventilation. The aim of this study was determination of indoor environmental quality in selected offices in the building of elementary school in Slovakia. The values of operative temperature were not within the optimum range of values for the warm period of the year in one of the monitored offices. The intensity of illumination was lower in the two offices. Low levels of particulate matters were measured except the one office where permissible value was exceeded by 7.6%.


2020 ◽  
Vol 170 ◽  
pp. 05004
Author(s):  
Anjali Jadhav ◽  
Sushma Kulkarni ◽  
Ashish Rege

India has a great cultural heritage of temples across the country. There is a wide variety of temples of variety of deities constructed from East to West and North to South of India. Most of the temples are built centuries ago and still are in good condition and the centre of cultural activities. Mahalaxmi temple precinct is a very old precinct in Kolhapur, built in 8th century by Chalukyan rulers. Every year lacs of devotees are visiting this temple of goddess Mahalaxmi from most of the part of India. The temple is constructed of basalt stone with beautiful intricate carving on it. This paper focus on indoor environmental quality of the temple which is deteriorated due to the impact of increased number of devotees. Some of the devotees face the problem of suffocation, fatigue, fainting, irritation, nasal congestion; as provision of vents are absent and natural ventilation is not available inside the shrine of goddess Mahalaxmi. Due to lack of air exchange and natural ventilation the indoor environmental quality is deteriorated. It is observed that the CO2 level is increased, decreased in O2 level, rise in temperature and humidity above the standard level causing discomfort.


Sign in / Sign up

Export Citation Format

Share Document