scholarly journals Analysis and Application of Automated Methods for Detecting Pulsars in the Green Bank Telescope 350MHz Drift-Scan Survey

2013 ◽  
Author(s):  
David Paul Smithbauer
2012 ◽  
Vol 8 (S291) ◽  
pp. 41-46
Author(s):  
Ryan S. Lynch

AbstractThe Green Bank Telescope (GBT) is the largest fully steerable radio telescope in the world and is one of our greatest tools for discovering and studying radio pulsars. Over the last decade, the GBT has successfully found over 100 new pulsars through large-area surveys. Here I discuss the two most recent—the GBT 350 MHz Drift-scan survey and the Green Bank North Celestial Cap survey. The primary science goal of both surveys is to find interesting individual pulsars, including young pulsars, rotating radio transients, exotic binary systems, and especially bright millisecond pulsars (MSPs) suitable for inclusion in Pulsar Timing Arrays, which are trying to directly detect gravitational waves. These two surveys have combined to discover 85 pulsars to date, among which are 14 MSPs and many unique and fascinating systems. I present highlights from these surveys and discuss future plans. I also discuss recent results from targeted GBT pulsar searches of globular clusters and Fermi sources.


2012 ◽  
Vol 8 (S291) ◽  
pp. 107-110
Author(s):  
Chen Karako-Argaman ◽  

AbstractRotating Radio Transients (RRATs) are a class of pulsars characterized by sporadic bursts of radio emission, which make them difficult to detect in typical periodicity-based pulsar searches. Using newly developed post-processing techniques for automatically identifying single bright astrophysical pulses, such as those emitted from RRATs, we have discovered approximately 30 new RRAT candidates in data from the Green Bank Telescope 350 MHz drift-scan survey. A total of 6 of these have already been confirmed and the remainder look extremely promising. Here we describe these techniques and present the most recent results on these new RRAT candidates.


2013 ◽  
Vol 763 (2) ◽  
pp. 81 ◽  
Author(s):  
Ryan S. Lynch ◽  
Jason Boyles ◽  
Scott M. Ransom ◽  
Ingrid H. Stairs ◽  
Duncan R. Lorimer ◽  
...  

2013 ◽  
Vol 763 (2) ◽  
pp. 80 ◽  
Author(s):  
J. Boyles ◽  
R. S. Lynch ◽  
S. M. Ransom ◽  
I. H. Stairs ◽  
D. R. Lorimer ◽  
...  

1978 ◽  
Vol 39 (02) ◽  
pp. 455-465 ◽  
Author(s):  
Yvonne Stirling ◽  
D J Howarth ◽  
Marguerite Vickers ◽  
W R S North ◽  
T W Meade

SummaryTwo automated methods for two-stage factor VIII assays have been compared with one another, and evaluated in practice. The Depex method records the clotting time when an electric circuit is completed by the formation of a fibrin thread across a hook-type electrode; the Electra method is based on an optical density technique of clot detection. The two methods gave comparable results for measured levels of factor VIII when haemophilic or “normal” plasmas were assayed. Results from the two methods in practice also suggest that both are valid at low and “normal” factor VIII levels. The Electra method is also probably suitable for assays of concentrates; however, the Depex method appears to give falsely high values in these circumstances, and experimental findings suggest that the reason may be that increased viscosity due to the high fibrinogen levels in factor VIII concentrates causes premature closure of the circuit between the two ends of the Depex electrode. The main advantage of the Depex method is that, provided 3 or 4 machines are available, a given number of assays can be completed more quickly than on Electra. The main advantages of Electra are that it is probably subject to less laboratory error than Depex, and that it is suitable for assaying concentrates as well as haemophilic and “normal” plasmas.


2019 ◽  
Vol 12 (3) ◽  
pp. 229-237 ◽  
Author(s):  
Alban Revy ◽  
François Hallouard ◽  
Sandrine Joyeux-Klamber ◽  
Andrea Skanjeti ◽  
Catherine Rioufol ◽  
...  

Objective: Recent gallium-68 labeled peptides are of increasing interest in PET imaging in nuclear medicine. Somakit TOC® is a radiopharmaceutical kit registered in the European Union for the preparation of [68Ga]Ga-DOTA-TOC used for the diagnosis of neuroendocrine tumors. Development of a labeling process using a synthesizer is particularly interesting for the quality and reproducibility of the final product although only manual processes are described in the Summary of Product (SmPC) of the registered product. The aim of the present study was therefore to evaluate the feasibility and value of using an automated synthesizer for the preparation of [68Ga]Ga-DOTA-TOC according to the SmPC of the Somakit TOC®. Methods: Three methods of preparation were compared; each followed the SmPC of the Somakit TOC®. Over time, overheads, and overexposure were evaluated for each method. Results: Mean±SD preparation time was 26.2±0.3 minutes for the manual method, 28±0.5 minutes for the semi-automated, and 40.3±0.2 minutes for the automated method. Overcost of the semi-automated method is 0.25€ per preparation for consumables and from 0.58€ to 0.92€ for personnel costs according to the operator (respectively, technician or pharmacist). For the automated method, overcost is 70€ for consumables and from 4.06€ to 6.44€ for personnel. For the manual method, extremity exposure was 0.425mSv for the right finger, and 0.350mSv for the left finger; for both the semi-automated and automated method extremity exposure were below the limit of quantification. Conclusion: The present study reports for the first time both the feasibility of using a [68Ga]- radiopharmaceutical kit with a synthesizer and the limits for the development of a fully automated process.


Author(s):  
K.F. Warnick ◽  
M. Ruzindana ◽  
B.D. Jeffs ◽  
R.A. Black ◽  
M. Burnett ◽  
...  
Keyword(s):  
L Band ◽  

Sign in / Sign up

Export Citation Format

Share Document