Faculty Opinions recommendation of Evaluation of a mandatory quality assurance data capture in anesthesia: a secure electronic system to capture quality assurance information linked to an automated anesthesia record.

Author(s):  
Mitchell Tsai ◽  
Brian Monroe
Author(s):  
Eldar Sultanow ◽  
Alina M. Chircu

This chapter illustrates the potential of data-driven track-and-trace technology for improving healthcare through efficient management of internal operations and better delivery of services to patients. Track-and-trace can help healthcare organizations meet government regulations, reduce cost, provide value-added services, and monitor and protect patients, equipment, and materials. Two real-world examples of commercially available track-and-trace systems based on RFID and sensors are discussed: a system for counterfeiting prevention and quality assurance in pharmaceutical supply chains and a monitoring system. The system-generated data (such as location, temperature, movement, etc.) about tracked entities (such as medication, patients, or staff) is “big data” (i.e. data with high volume, variety, velocity, and veracity). The chapter discusses the challenges related to data capture, storage, retrieval, and ultimately analysis in support of organizational objectives (such as lowering costs, increasing security, improving patient outcomes, etc.).


Big Data ◽  
2016 ◽  
pp. 1229-1246
Author(s):  
Eldar Sultanow ◽  
Alina M. Chircu

This chapter illustrates the potential of data-driven track-and-trace technology for improving healthcare through efficient management of internal operations and better delivery of services to patients. Track-and-trace can help healthcare organizations meet government regulations, reduce cost, provide value-added services, and monitor and protect patients, equipment, and materials. Two real-world examples of commercially available track-and-trace systems based on RFID and sensors are discussed: a system for counterfeiting prevention and quality assurance in pharmaceutical supply chains and a monitoring system. The system-generated data (such as location, temperature, movement, etc.) about tracked entities (such as medication, patients, or staff) is “big data” (i.e. data with high volume, variety, velocity, and veracity). The chapter discusses the challenges related to data capture, storage, retrieval, and ultimately analysis in support of organizational objectives (such as lowering costs, increasing security, improving patient outcomes, etc.).


Author(s):  
Keith J. Ruskin ◽  
Ori Gottlieb

Anesthesia information management systems (AIMS) offer significant benefits to an anesthesiologist who practices beyond the operating room. AIMS systems have the potential to improve patient care because they deliver a customized, legible anesthesia record while storing the patient’s physiologic data in an easily searchable database. An electronic workflow allows the anesthesiologist to focus on patient care while facilitating tasks such as quality assurance, compliance, research, and billing.


2011 ◽  
Vol 112 (5) ◽  
pp. 1218-1225 ◽  
Author(s):  
Robert A. Peterfreund ◽  
William D. Driscoll ◽  
John L. Walsh ◽  
Aparna Subramanian ◽  
Shaji Anupama ◽  
...  

2018 ◽  
pp. 1-12 ◽  
Author(s):  
Dario Pasalic ◽  
Jay P. Reddy ◽  
Timothy Edwards ◽  
Hubert Y. Pan ◽  
Benjamin D. Smith

Purpose To describe the feasibility and benefits of implementing a custom radiation oncology electronic data capture (EDC) system in a large academic radiation oncology practice. Patients and Methods A Web-based point-and-click EDC known as Brocade was internally developed and implemented systemwide in 2016. Brocade captures key data elements, such as stage, histology, and patient and treatment characteristics; links this information to radiation dose data extracted from the record and verify system; and creates clinical notes that are automatically exported to the hospital electronic health record. We report the number of unique radiation episodes captured by Brocade in its first full year of implementation and describe the notes generated, toxicities captured, compliance with staging and quality assurance, and time of day in which documentation occurred with Brocade versus our prior human transcription system. Results A median of 756 radiation episodes per month was captured for a total of 9,283 unique episodes captured in the first full year of implementation. The most common notes were for on-treatment visits (29,913) and simulations (13,220). Stage was captured for 92.2% of Brocade episodes (8,513 of 9,236) versus 29.7% of courses pre-Brocade (3,025 of 10,170; P < .001). Quality assurance was documented for 96.3% of completed courses (7,601 of 7,892). The most common grade ≥1 toxicities were pain (10,031), fatigue (7,490), and dermatitis (6,172). Brocade implementation was associated with a reduction in off-hours documentation and increase in the proportion of documentation created between 8:00 am and 12:00 pm. Conclusion Brocade is a reliable Web-based EDC tool that improves clinical documentation without detracting from clinical workflow. Moreover, Brocade has the advantage of capturing data in a structured manner that facilitates real-time analytics and outcome reporting.


2021 ◽  
Vol 6 (Suppl 5) ◽  
pp. e005287
Author(s):  
Neha Shah ◽  
Osama Ummer ◽  
Kerry Scott ◽  
Jean Juste Harrisson Bashingwa ◽  
Nehru Penugonda ◽  
...  

The increasing use of digital health solutions to support data capture both as part of routine delivery of health services and through special surveys presents unique opportunities to enhance quality assurance measures. This study aims to demonstrate the feasibility and acceptability of using back-end data analytics and machine learning to identify impediments in data quality and feedback issues requiring follow-up to field teams using automated short messaging service (SMS) text messages. Data were collected as part of a postpartum women’s survey (n=5095) in four districts of Madhya Pradesh, India, from October 2019 to February 2020. SMSs on common errors found in the data were sent to supervisors and coordinators. Before/after differences in time to correction of errors were examined, and qualitative interviews conducted with supervisors, coordinators, and enumerators. Study activities resulted in declines in the average number of errors per week after the implementation of automated feedback loops. Supervisors and coordinators found the direct format, complete information, and automated nature of feedback convenient to work with and valued the more rapid notification of errors. However, coordinators and supervisors reported preferring group WhatsApp messages as compared with individual SMSs to each supervisor/coordinator. In contrast, enumerators preferred the SMS system over in-person group meetings where data quality impediments were discussed. This study demonstrates that automated SMS feedback loops can be used to enhance survey data quality at minimal cost. Testing is needed among data capture applications in use by frontline health workers in India and elsewhere globally.


2020 ◽  
Vol 305 ◽  
pp. 70-76
Author(s):  
Li You Zhao ◽  
Ze Bin Kong

Electrical connector is an important component in electronic system, and its reliability directly affects the reliability of the whole system. Corrosion often occurs in the use of electrical connectors and leads to failure. This paper summarizes the corrosion failure analysis process of three kinds of connectors. The failure types include fluorine corrosion, electrolytic corrosion and sweat corrosion. The quality assurance measures of Anticorrosion for electrical connectors are expounded.


Author(s):  
E. Rau ◽  
N. Karelin ◽  
V. Dukov ◽  
M. Kolomeytsev ◽  
S. Gavrikov ◽  
...  

There are different methods and devices for the increase of the videosignal information in SEM. For example, with the help of special pure electronic [1] and opto-electronic [2] systems equipotential areas on the specimen surface in SEM were obtained. This report generalizes quantitative universal method for space distribution representation of research specimen parameter by contour equal signal lines. The method is based on principle of comparison of information signal value with the fixed levels.Transformation image system for obtaining equal signal lines maps was developed in two versions:1)In pure electronic system [3] it is necessary to compare signal U (see Fig.1-a), which gives potential distribution on specimen surface along each scanning line with fixed base level signals εifor obtaining quantitative equipotential information on solid state surface. The amplitude analyzer-comparator gives flare sport videopulses at any fixed coordinate and any instant time when initial signal U is equal to one of the base level signals ε.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Sign in / Sign up

Export Citation Format

Share Document