Responses of Fourier Transform-Surface Plasmon Resonance Frequency to Refractive Index of the Solution in Contact with the Gold Film

2012 ◽  
Vol 29 (2) ◽  
pp. 222
Author(s):  
Jizheng WEI ◽  
Yubin HUANG ◽  
Xiabin JING
2006 ◽  
Vol 89 (10) ◽  
pp. 103107 ◽  
Author(s):  
K. C. Chu ◽  
C. Y. Chao ◽  
Y. F. Chen ◽  
Y. C. Wu ◽  
C. C. Chen

Biosensors ◽  
2018 ◽  
Vol 8 (4) ◽  
pp. 113 ◽  
Author(s):  
Weifeng Lv ◽  
Chenjie Gu ◽  
Shuwen Zeng ◽  
Jiaguang Han ◽  
Tao Jiang ◽  
...  

Gold nanoparticles with multiple branches have attracted intensive studies for their application in sensing of low trace molecules. A large number of the merits found on the gold nanoparticles for the above applications are attributed to the strong localized surface plasmon resonance excited by the incident radiation. However, a facile and flexible way of synthesizing the multi-branch gold nanoparticles with tunable localized surface plasmon resonance frequency is still a challenge for the plasmonic research field. Herein, we report an efficient one-pot synthesis of multi-branch gold nanoparticles method that resembles a seed-medicated approach while using no further chemicals except chloroauric acid, ascorbic acid and 4-(2-Hydroxyethyl)-1-piperazinyl]-ethanesulfonic acid. By controlling the amounts of ascorbic acid volumes in the reaction mixture, the morphology and the localized surface plasmon resonance frequency of the synthesized multi-branch gold nanoparticles can be manipulated conveniently. Moreover, using the 4-Mercaptobenzoic acid as the Raman reporter, the multi-branch gold nanoparticles show superior surface-enhanced Raman spectroscopy characteristics that can be potentially used in chemical and biological sensing.


Sensors ◽  
2019 ◽  
Vol 19 (17) ◽  
pp. 3666 ◽  
Author(s):  
Bin Li ◽  
Tonglei Cheng ◽  
Junxin Chen ◽  
Xin Yan

A surface plasmon resonance (SPR) liquid refractive index sensor based on photonic crystal fiber (PCF) is proposed. The PCF is made of the exposed core structure, and the gold film is formed by electron beam evaporation within its defects. The sensitivity of the sensor is improved by coating graphene on the surface of the gold film. The experimental results show that the sensitivity of the sensor is increased by 390 nm/RIU after the introduction of graphene, and finally to 2290 nm/RIU. The experiment and simulation have a good consistency. Significantly, the sensor can be reused, and the measurement accuracy can be maintained.


Sign in / Sign up

Export Citation Format

Share Document