Improved Zhang′s Calibration Method and Experiments for Underwater Binocular Stereo-Vision

2014 ◽  
Vol 34 (12) ◽  
pp. 1215006 ◽  
Author(s):  
李光乐 Li Guangle ◽  
黄文有 Huang Wenyou ◽  
刘青松 Liu Qingsong ◽  
邓志燕 Deng Zhiyan
2013 ◽  
Vol 397-400 ◽  
pp. 1547-1551
Author(s):  
Hui Yu Xiang ◽  
Bao An Han ◽  
Zhe Li ◽  
Jia Jun Huang

For the research of camera calibration in the system of grid strain measurement in sheet forming, the pinhole camera model, the nonlinear model of the camera and the binocular stereo model are analyzed, drawing a binocular stereo calibration method based on HALCON, which detailedly describes the calibration principle and specific calibration process. A binocular stereo vision calibration system based on VC6.0 is established, by which the influence on camera focus, distortion factor and principle points from the number of calibration images is verified by experiments.


2015 ◽  
Vol 740 ◽  
pp. 531-534 ◽  
Author(s):  
Tao He ◽  
Jiu Yin Chen ◽  
Xiang Hu ◽  
Xian Wang

It is important to obtain the 3d coordinate in the field of measuring. How accurate, fast, convenient to obtain the 3d coordinate affects the accuracy and reliability of measurement directly. Through studying the basic theories of machine vision this paper focus on the study of a stereo vision measurement model based on the intersecting axis. In view of the parameters in the model of binocular stereo vision, this paper uses the Zhang Zhengyou calibration method to calibrate the system of Stereo vision. In order to test the accuracy of the system, this paper measures the distance of two standard circular. Finally, the machining experiment validates the proposed method.


Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3666 ◽  
Author(s):  
Yue Wang ◽  
Xiangjun Wang ◽  
Zijing Wan ◽  
Jiahao Zhang

Nowadays, binocular stereo vision (BSV) is extensively used in real-time 3D reconstruction, which requires cameras to quickly implement self-calibration. At present, the camera parameters are typically estimated through iterative optimization. The calibration accuracy is high, but the process is time consuming. Hence, a system of BSV with rotating and non-zooming cameras is established in this study, in which the cameras can rotate horizontally and vertically. The cameras’ intrinsic parameters and initial position are estimated in advance by using Zhang’s calibration method. Only the yaw rotation angle in the horizontal direction and pitch in the vertical direction for each camera should be obtained during rotation. Therefore, we present a novel self-calibration method by using a single feature point and transform the imaging model of the pitch and yaw into a quadratic equation of the tangent value of the pitch. The closed-form solutions of the pitch and yaw can be obtained with known approximate values, which avoid the iterative convergence problem. Computer simulation and physical experiments prove the feasibility of the proposed method. Additionally, we compare the proposed method with Zhang’s method. Our experimental data indicate that the averages of the absolute errors of the Euler angles and translation vectors relative to the reference values are less than 0.21° and 6.6 mm, respectively, and the averages of the relative errors of 3D reconstruction coordinates do not exceed 4.2%.


2013 ◽  
Vol 397-400 ◽  
pp. 1453-1458 ◽  
Author(s):  
Yu Bao Liu ◽  
Bin Liu ◽  
Jun Yi Lin

It is a difficult task to get enough numbers of highly accurate control points for projector calibration in line structured light vision system. A new projector calibration method based on binocular stereo vision is proposed in this paper. Two cameras calibration can be done usingtraditional camera calibration method and they composed a binocular stereo vision. In projector calibration procedure, a planar template was located at several different positions in front of the stereo vision system. Two cameras captured the stripe images in each position simultaneously. Every center points of the laser stripe can be used as control points of the projector plane. The 3D coordinate of the stripe center points can be obtained through binocular stereo vision principle easily. So the light plane can be calculated quickly. Experiments were carried out and the result shows that the proposed method is flexible and stable.


2011 ◽  
Vol 305 ◽  
pp. 372-377
Author(s):  
Ke Zhang ◽  
Han Pin Luo

Computer stereo vision has been paid high attention in areas such as industry measurement and automatic control. Calibration of stereo vision system is a key step to implement vision measurement. Nonlinear calibration method involves too many parameters and too complex function, so the processing of optimization is difficult and slow. In this paper, two digital cameras are used to set up stereo vision system which provides convenient experimental operation. The binocular stereo vision system is calibrated using linear calibration model. The results indicate that the method is stable and fast with high precision and practicability.


Sign in / Sign up

Export Citation Format

Share Document