A Method of Line Structured Light Vision System Calibration Based on Stereo Vision

2013 ◽  
Vol 397-400 ◽  
pp. 1453-1458 ◽  
Author(s):  
Yu Bao Liu ◽  
Bin Liu ◽  
Jun Yi Lin

It is a difficult task to get enough numbers of highly accurate control points for projector calibration in line structured light vision system. A new projector calibration method based on binocular stereo vision is proposed in this paper. Two cameras calibration can be done usingtraditional camera calibration method and they composed a binocular stereo vision. In projector calibration procedure, a planar template was located at several different positions in front of the stereo vision system. Two cameras captured the stripe images in each position simultaneously. Every center points of the laser stripe can be used as control points of the projector plane. The 3D coordinate of the stripe center points can be obtained through binocular stereo vision principle easily. So the light plane can be calculated quickly. Experiments were carried out and the result shows that the proposed method is flexible and stable.

2011 ◽  
Vol 305 ◽  
pp. 372-377
Author(s):  
Ke Zhang ◽  
Han Pin Luo

Computer stereo vision has been paid high attention in areas such as industry measurement and automatic control. Calibration of stereo vision system is a key step to implement vision measurement. Nonlinear calibration method involves too many parameters and too complex function, so the processing of optimization is difficult and slow. In this paper, two digital cameras are used to set up stereo vision system which provides convenient experimental operation. The binocular stereo vision system is calibrated using linear calibration model. The results indicate that the method is stable and fast with high precision and practicability.


2011 ◽  
Vol 460-461 ◽  
pp. 219-224 ◽  
Author(s):  
Jun Tao Xiong ◽  
Xiang Jun Zou ◽  
Hai Xin Zou ◽  
Yin Le Chen ◽  
Quan Sun

Aiming at the camera calibration of binocular stereo vision system, based on Zhang’s calibration method, the specified points in the calibration template obtained by the Harris operator, a set of camera calibration system combined with VC++ and Matlab was developed. The results of the calibration system, comparing with those of four-step calibration method, was analyzed and showed that: the error of calibration data in this system was within 0~5 mm, which had a high precision calibration, providing a new reference measure for the camera calibration.


2014 ◽  
Vol 989-994 ◽  
pp. 3007-3010
Author(s):  
Zhi Xian Zhang ◽  
Zhen De Zhu

This paper describes the pinhole camera model combined with an area sensor and a regular lens and the imaging model of the binocular stereo vision system. Also a method to determine the internal and external parameters of a camera by transferring the coordinates three times is described. Then a calibration experiment is carried out with the Halcon calibration board which proved the method works. The method mentioned in this paper has laid a good foundation for measuring the size of objects with the binocular stereo vision system.


2020 ◽  
Author(s):  
Pengcheng Wang ◽  
Zenghong Ma ◽  
Xiaoqiang Du ◽  
Wenwu Lu ◽  
Wensong Xing ◽  
...  

2004 ◽  
Vol 126 (1) ◽  
pp. 102-114 ◽  
Author(s):  
Psang Dain Lin ◽  
Te-tan Liao

Two-CCD binocular stereo vision systems using pinhole model are attracting research interest in many important fields such as 3-D coordinate measurement. However, new system modeling is difficult because of lack of fundamental imaging formation theory. In this paper, in order to measure a 3-D surface, we demonstrate how a binocular stereo vision system can be modeled by the proposed skew ray tracing method to study the geometric relations between the binocular camera images and the 3-D surface. In order to investigate the overall accuracy and resolution of this system, the influence of infinitesimal camera reading errors on measured coordinate errors is determined by sensitivity analysis. Experimental verification demonstrates that the performance of the proposed system is excellent.


2013 ◽  
Vol 662 ◽  
pp. 777-780
Author(s):  
Wen Guo Li ◽  
Shao Jun Duan

We present a convenient calibration method for structured light projection system. The proposed clibration approach can realize 3D shape measurement without projector calibration, without system calibration, without precise linear z stage to be used, the relative position between camera and projector can be arbitrary, and the only involved device is a plane board. Experiment results validated that the accuracy of the proposed approach.


2013 ◽  
Vol 397-400 ◽  
pp. 1547-1551
Author(s):  
Hui Yu Xiang ◽  
Bao An Han ◽  
Zhe Li ◽  
Jia Jun Huang

For the research of camera calibration in the system of grid strain measurement in sheet forming, the pinhole camera model, the nonlinear model of the camera and the binocular stereo model are analyzed, drawing a binocular stereo calibration method based on HALCON, which detailedly describes the calibration principle and specific calibration process. A binocular stereo vision calibration system based on VC6.0 is established, by which the influence on camera focus, distortion factor and principle points from the number of calibration images is verified by experiments.


Sign in / Sign up

Export Citation Format

Share Document