Multi-spectral imaging system based on artificial-compound-eye

2014 ◽  
Vol 22 (10) ◽  
pp. 2691-2697
Author(s):  
金建 JIN Jian ◽  
邸思 DI Si ◽  
陈贤帅 CHEN Xian-shuai ◽  
杜如虚 DU Ru-xu
Micromachines ◽  
2019 ◽  
Vol 10 (3) ◽  
pp. 208 ◽  
Author(s):  
Axiu Cao ◽  
Hui Pang ◽  
Man Zhang ◽  
Lifang Shi ◽  
Qiling Deng ◽  
...  

The artificial compound eye (ACE) structure is a new type of miniaturized, lightweight and intelligent imaging system. This paper has proposed to design a multi-spectral ACE structure to enable the structure to achieve multi-spectral information on the basis of imaging. The sub-eyes in the compound eye structure have been designed as diffractive beam splitting lenses with the same focal length of 20 mm, but with the different designed center wavelengths of 650 nm, 532 nm, and 445 nm, respectively. The proximity exposure lithography and reactive ion etching process were used to prepare the designed multi-spectral ACE structure, and the spectral splitting and multi-spectral imaging experiments were carried out to verify the multi-spectral imaging function of the structure without axial movement. Furthermore, the structure can be designed according to actual requirements, which can be applied to covert reconnaissance, camouflage identification, gas leakage or other fields.


2021 ◽  
Vol 11 (12) ◽  
pp. 5628
Author(s):  
Run Fang ◽  
Libo Zeng ◽  
Fan Yi

Multi-spectral imaging technique plays an important role in real-world applications such as medicine and medical detections. This paper proposes a cervical cancer cell screening method to simultaneously adopt TBS classification and DNA quantitative analysis for a single cell smear. Through using compound staining on a smear, the cytoplasm is stained by Papanicolauo and the nucleus is stained by Feulgen. The main evaluation parameter is the DNA content of the nucleus, not the subjective description of cell morphology, which is more objective than the TBS classification method and reduces the chances of missing a diagnosis due to subjective factors. Each nucleus has its own DI value and color image of the whole cell, which is convenient for doctors as it allows them to review and confirm the morphology of cells with a nucleus DI of over 2.5. Mouse liver smears and cervical cases are utilized as the measuring specimens to evaluate the performance of the microscope multi-spectral imaging system; illustrative results demonstrate that the proposed system qualifies, with high accuracy and reliability, and further presents wide application prospects in the early diagnosis of cervical cancer.


2011 ◽  
Vol 78 (11) ◽  
pp. 503-507 ◽  
Author(s):  
Martin De Biasio ◽  
T. Arnold ◽  
R. Leitner

2015 ◽  
Vol 41 (6) ◽  
pp. 585-595 ◽  
Author(s):  
Jinxing Liang ◽  
Xiaoxia Wan ◽  
Qiang Liu ◽  
Chan Li ◽  
Junfeng Li

2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Isaac August ◽  
Yaniv Oiknine ◽  
Marwan AbuLeil ◽  
Ibrahim Abdulhalim ◽  
Adrian Stern

2021 ◽  
Author(s):  
Eleni Aloupogianni ◽  
Masahiro Ishikawa ◽  
Takaya Ichimura ◽  
Atsushi Sasaki ◽  
Naoki Kobayashi ◽  
...  

2014 ◽  
Vol 43 (11) ◽  
pp. 1122001
Author(s):  
高天元 GAO Tian-yuan ◽  
董正超 DONG Zheng-chao ◽  
赵宇 ZHAO Yu ◽  
刘智颖 LIU Zhi-ying

Sign in / Sign up

Export Citation Format

Share Document