scholarly journals Design and Fabrication of an Artificial Compound Eye for Multi-Spectral Imaging

Micromachines ◽  
2019 ◽  
Vol 10 (3) ◽  
pp. 208 ◽  
Author(s):  
Axiu Cao ◽  
Hui Pang ◽  
Man Zhang ◽  
Lifang Shi ◽  
Qiling Deng ◽  
...  

The artificial compound eye (ACE) structure is a new type of miniaturized, lightweight and intelligent imaging system. This paper has proposed to design a multi-spectral ACE structure to enable the structure to achieve multi-spectral information on the basis of imaging. The sub-eyes in the compound eye structure have been designed as diffractive beam splitting lenses with the same focal length of 20 mm, but with the different designed center wavelengths of 650 nm, 532 nm, and 445 nm, respectively. The proximity exposure lithography and reactive ion etching process were used to prepare the designed multi-spectral ACE structure, and the spectral splitting and multi-spectral imaging experiments were carried out to verify the multi-spectral imaging function of the structure without axial movement. Furthermore, the structure can be designed according to actual requirements, which can be applied to covert reconnaissance, camouflage identification, gas leakage or other fields.

2014 ◽  
Vol 22 (10) ◽  
pp. 2691-2697
Author(s):  
金建 JIN Jian ◽  
邸思 DI Si ◽  
陈贤帅 CHEN Xian-shuai ◽  
杜如虚 DU Ru-xu

2021 ◽  
Vol 11 (12) ◽  
pp. 5628
Author(s):  
Run Fang ◽  
Libo Zeng ◽  
Fan Yi

Multi-spectral imaging technique plays an important role in real-world applications such as medicine and medical detections. This paper proposes a cervical cancer cell screening method to simultaneously adopt TBS classification and DNA quantitative analysis for a single cell smear. Through using compound staining on a smear, the cytoplasm is stained by Papanicolauo and the nucleus is stained by Feulgen. The main evaluation parameter is the DNA content of the nucleus, not the subjective description of cell morphology, which is more objective than the TBS classification method and reduces the chances of missing a diagnosis due to subjective factors. Each nucleus has its own DI value and color image of the whole cell, which is convenient for doctors as it allows them to review and confirm the morphology of cells with a nucleus DI of over 2.5. Mouse liver smears and cervical cases are utilized as the measuring specimens to evaluate the performance of the microscope multi-spectral imaging system; illustrative results demonstrate that the proposed system qualifies, with high accuracy and reliability, and further presents wide application prospects in the early diagnosis of cervical cancer.


2021 ◽  
Vol 2112 (1) ◽  
pp. 012021
Author(s):  
Chong Song ◽  
Lipeng Huo ◽  
Yong Huang ◽  
Yangdong Yan ◽  
Gang Wang ◽  
...  

Abstract Based on the optical system characteristics of coded aperture snapshot spectral imager (CASSI), an optimized optical system of shortwave infrared dual camera CASSI was designed based on improved Offner-Wynne imaging spectrometer. The operating wavelength of the optical system ranges from 900nm to 1700nm, and the focal length is 1200mm. It consists of two parts: the two dimensional imaging system and the multispectral CASSI imaging system. The key technical parameters of the two parts are the same and there is no visual axis difference. Therefore, the optimized optical system can effectively improve real-time performance, optical transmittance and compactness of the dual camera shortwave infrared CASSI, which is conducive to the application in optical measurement scenes in the shooting range.


2011 ◽  
Vol 78 (11) ◽  
pp. 503-507 ◽  
Author(s):  
Martin De Biasio ◽  
T. Arnold ◽  
R. Leitner

2015 ◽  
Vol 41 (6) ◽  
pp. 585-595 ◽  
Author(s):  
Jinxing Liang ◽  
Xiaoxia Wan ◽  
Qiang Liu ◽  
Chan Li ◽  
Junfeng Li

2016 ◽  
Vol 6 (1) ◽  
Author(s):  
Isaac August ◽  
Yaniv Oiknine ◽  
Marwan AbuLeil ◽  
Ibrahim Abdulhalim ◽  
Adrian Stern

Sign in / Sign up

Export Citation Format

Share Document