Experimental Study on the Heat Transfer Performance and Pressure Drop of Fin-and-Tube Heat Exchangers Having Non-symmetric Slit Fins

2019 ◽  
Vol 43 (9) ◽  
pp. 661-669
Author(s):  
Nae-Hyun Kim
2013 ◽  
Vol 832 ◽  
pp. 160-165 ◽  
Author(s):  
Mohammad Alam Khairul ◽  
Rahman Saidur ◽  
Altab Hossain ◽  
Mohammad Abdul Alim ◽  
Islam Mohammed Mahbubul

Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide excellent thermal performance of this type of heat exchangers. In the present study, the effect of different nanofluids on the heat transfer performance in a helically coiled heat exchanger is examined. Four different types of nanofluids CuO/water, Al2O3/water, SiO2/water, and ZnO/water with volume fractions 1 vol.% to 4 vol.% was used throughout this analysis and volume flow rate was remained constant at 3 LPM. Results show that the heat transfer coefficient is high for higher particle volume concentration of CuO/water, Al2O3/water and ZnO/water nanofluids, while the values of the friction factor and pressure drop significantly increase with the increase of nanoparticle volume concentration. On the contrary, low heat transfer coefficient was found in higher concentration of SiO2/water nanofluids. The highest enhancement of heat transfer coefficient and lowest friction factor occurred for CuO/water nanofluids among the four nanofluids. However, highest friction factor and lowest heat transfer coefficient were found for SiO2/water nanofluids. The results reveal that, CuO/water nanofluids indicate significant heat transfer performance for helically coiled heat exchanger systems though this nanofluids exhibits higher pressure drop.


2013 ◽  
Vol 423-426 ◽  
pp. 1910-1913
Author(s):  
Jian Rong Du ◽  
Zu Yi Zheng ◽  
Jun Hua Wan ◽  
Yi De Wang ◽  
Zhong Min Wan ◽  
...  

Three heat exchangers, all of which have 38 tubes in total and 6 passes, with different tube arrangements were simulation investigated in laboratory. The effect of flat tube distribution on heat transfer performance and pressure drop characteristic was simulation investigated. The effect of different air velocity and flow on heat transfer performance and pressure drop characteristic was simulation investigated too. The results show that similar tube distribution has little effect on heat transfer but has great effect on pressure drop. It was found the tube arrangement from first pass to sixth pass is 10,9,6,5,4,4 has the best heat transfer performance and its pressure drop is small. The heat transfer and pressure drop increase with the air velocity and refrigerant flow.


2014 ◽  
Vol 701-702 ◽  
pp. 1233-1236
Author(s):  
Lv Xian Zeng ◽  
Zu Yi Zheng ◽  
Jun Hua Wan ◽  
Xi Chen ◽  
Zhong Min Wan ◽  
...  

Three heat exchangers, all of which have 38 tubes in total and 6 passes, with different tube arrangements were manufactured to be experimental investigated in laboratory. The effect of flat tube distribution on heat transfer performance and pressure drop characteristic was experimental investigated. The effect of different air velocity and flow on heat transfer performance and pressure drop characteristic was also experimental investigated. The results show that similar tube distribution has little effect on heat transfer quality but has great effect on pressure drop. It was found the third arrangement has the best heat transfer and its pressure drop is small. Thus the third arrangement is the best solution. The heat transfer and pressure drop increase with the air velocity and refrigerant flow, so a proper value should be chosen, it was found that the simulation results were mainly agreement with the experimental results.


2014 ◽  
Vol 11 (4) ◽  
Author(s):  
Hie Chan Kang ◽  
Hyejung Cho ◽  
Jin Ho Kim ◽  
Anthony M. Jacobi

The present work is performed to evaluate the heat transfer performance of a heat exchanger used in a direct methanol fuel cell. Because of material constraints and performance requirements, a louver fin heat exchanger is modified for use with conventional microchannel tubes and also with multiple small-diameter tubes (called multitubes). Prototype heat exchangers are tested, and the air-side heat transfer, pressure drop, and fan power are measured in a wind tunnel and simulated using a commercial code. The air-side pressure drop and heat transfer coefficient of the multitubes show similar trends to those of the flat-tube heat exchanger if the contact resistance is negligible. The tube spacing of the prototype multitube heat exchangers has a small effect on the pressure drop and heat transfer, but it has a profound effect on the air-side heat transfer performance because of the contact resistance between the tubes and louver fins. The air-side pressure drop agrees well with an empirical correlation for flat tubes.


2016 ◽  
Vol 24 (02) ◽  
pp. 1630004 ◽  
Author(s):  
Byung Hoon Shon ◽  
Seung Won Jeon ◽  
Yongchan Kim ◽  
Yong Tae Kang

In this paper, condensation and evaporation characteristics of low global warming potential (GWP) refrigerants such as R-1234yf and R-1234ze series are reviewed. This review focuses on heat transfer and pressure drop in plate heat exchangers. Mass flux is considered as an important factor while saturation temperature is not for condensation and evaporation process in plate heat exchangers. The dryout phenomenon occurs occasionally and gives greatly harmful impact on evaporation heat transfer. It is found that R-1234yf and R-1234ze(E) give slightly lower heat transfer performance than R-134a for both condensation and evaporation processes. Generally, low GWP refrigerants presented in this review give lower heat transfer coefficient and higher frictional pressure drop than the conventional refrigerants. Nevertheless, R-1234ze(Z) gives superior heat transfer performance than other refrigerants in condensation. R-32 gives remarkable performance in evaporation, but it gives relatively high GWP compared to other low GWP refrigerants.


2012 ◽  
Vol 20 (04) ◽  
pp. 1230003 ◽  
Author(s):  
S. LAOHALERTDECHA ◽  
A. S. DALKILIC ◽  
S. WONGWISES

The enhanced tube is a kind of the passive technique for improving the thermal performance of the heat exchangers with a little increase of the friction penalty. They have stated to use instead of the common smooth tubes for designing of the heat exchangers. The size of these heat exchangers can be reduced considerably by using the enhanced tubes instead of smooth tubes. Normally, they are divided into four groups: the corrugated tube, ribbed tube, grooved tube, and fluted tube. Compared with the common smooth tube, many researchers reported that use of the enhanced tubes dramatically increases the heat-transfer performance, both theoretically and experimentally. Focusing on the advantages of the enhanced tubes, this article summarizes the published studies on the heat-transfer and pressure-drop characteristics of the enhanced tubes, both experimental and quantitative investigations.


2019 ◽  
Vol 29 (11) ◽  
pp. 4334-4348
Author(s):  
Minqiang Pan ◽  
Hongqing Wang ◽  
Yujian Zhong ◽  
Tianyu Fang ◽  
Xineng Zhong

Purpose With the increasing heat dissipation of electronic devices, the cooling demand of electronic products is increasing gradually. A water-cooled microchannel heat exchanger is an effective cooling technology for electronic equipment. The structure of a microchannel has great impact on the heat transfer performance of a microchannel heat exchanger. The purpose of this paper is to analyze and compare the fluid flow and heat transfer characteristic of a microchannel heat exchanger with different reentrant cavities. Design/methodology/approach The three-dimensional steady, laminar developing flow and conjugate heat transfer governing equations of a plate microchannel heat exchanger are solved using the finite volume method. Findings At the flow rate range studied in this paper, the microchannel heat exchangers with reentrant cavities present better heat transfer performance and smaller pressure drop. A microchannel heat exchanger with trapezoidal-shaped cavities has best heat transfer performance, and a microchannel heat exchanger with fan-shaped cavities has the smallest pressure drop. Research limitations/implications The fluid is incompressible and the inlet temperature is constant. Practical implications It is an effective way to enhance heat transfer and reduce pressure drop by adding cavities in microchannels and the data will be helpful as guidelines in the selection of reentrant cavities. Originality/value This paper provides the pressure drop and heat transfer performance analysis of microchannel heat exchangers with various reentrant cavities, which can provide reference for heat transfer augmentation of an existing microchannel heat exchanger in a thermal design.