scholarly journals OZONE CONCENTRATION VARIATIONS NEAR HIGH‐VOLTAGE TRANSMISSION LINES/OZONO KONCENTRACIJOS KITIMAS TIES AUKŠTOSIOS ĮTAMPOS TIEKIMO LINIJOMIS/ИЗМЕНЕНИЯ КОНЦЕНТРАЦИИ ОЗОНА ВБЛИЗИ ВЫСОКОВОЛЬТНЫХ ЛИНИЙ ЭЛЕКТРОПЕРЕДАЧ

Author(s):  
Vaida Valuntaitė ◽  
Vaida Šerevičienė ◽  
Raselė Girgždienė

Changes and distribution of ozone concentration in the area of high‐voltage transmission lines were investigated. The investigation on ozone concentration changes was performed with application of two methods: by using an ozone analyser and by passive samplers. The role of an accumulating element was performed by a glass‐fiber filter installed in a passive sampler. It was impregnated with a 1.2‐di(4‐pyridyl)ethylene and acetate acid solution. The impact of meteorological parameters on the passive sampler efficiency and ozone concentration variation is discussed. These parameters can increase or decrease the real concentration value in comparison with the concentration obtained by co‐located continuously running ozone analyser. Ozone concentration near high‐voltage lines varied from 10 to 51 ppb, and “background” ozone concentration changed from 3 to 50 ppb during the investigation period. The average concentrations were 28.1 and 27.5 ppb near the lines and “background” during the whole experiment period. The wind direction from “background” location to the high‐voltage lines prevailed during the experiment. The obtained results by different methods demonstrated good agreement; the difference between ozone concentrations was from 1 to 24% for individual cases. Santrauka Tirta ozono koncentracijos kitimas ir pasiskirstymas ties aukštosios įtampos perdavimo linijomis. Ozono koncentracija matuota dviem metodais – ozono analizatoriumi ir pasyviaisiais kaupikliais. Pasyviajame kaupiklyje kaip kaupiantysis elementas buvo naudojamas stiklo pluošto filtras, impregnuotas 1,2-di(4-pyridyl)etileno ir acetatinės rūgšties tirpalu. Vėjo greitis, vėjo kryptis, UV spinduliuotė, temperatūra ir santykinė oro drėgmė gali turėti įtakos pasyviųjų kaupiklių efektyvumui bei ozono koncentracijos pasiskirstymui, todėl kartu tirti ir meteorologiniai parametrai (temperatūra, santykinė oro drėgmė, vėjo greitis ir kryptis). Tyrimo laikotarpiu ozono koncentracija ties aukštosios įtampos tiekimo linijomis kito nuo 10 iki 51 ppb, o nutolusioje per 222 m vietovėje, kuri buvo traktuojama kaip foninė, – nuo 3 iki 50 ppb. Išmatuota vidutinė ozono koncentracija foninėje vietoje buvo 27,5 ppb, o ties linijomis – 28,1 ppb. Eksperimento metu vyravo pietryčių krypties vėjas, t. y. nuo foninės vietos – aukštosios įtampos tiekimo linijų link. Nustatant ozono koncentraciją skirtingais metodais duomenys pakankamai sutapo, pavieniais atvejais nesutapimas svyravo nuo 1 iki 24 %. Резюме Исследовалось изменение и распределение концентрации озона в районе высоковольтных линий электропередач. Концентрация озона измерялась двумя методами: анализаторами озона УФ-поглощения непрерывного действия и с использованием пассивных сорбентов. В качестве сорбента использовался фильтр из стекловолокна, пропитанный 1,2-ди(4-пиридил)этиленом и уксусной кислотой. Параллельно непрерывно измерялась температура и относительная влажность воздуха, скорость и направление ветра. Исследования показали, что концентрация озона в течение эксперимента изменялась в интервале от 10 до 51 ррb у линии и от 3 до 50 ррb на «фоновой» точке, удаленной от линий электропередач на расстояние 222 м. В течение эксперимента почти половину времени преобладал боковой ветер по отношению к высоковольтным линиям со стороны фоновой точки. Средние измеренные концентрации озона составляли 27,5 ррb на «фоновой» точке и 28,1 ррb – у линий. Результаты измерения концентрации озона как анализаторами непрерывного действия, так и по методике с использованием пассивных сорбентов показали хорошее совпадение: разница составляла 2–15% и лишь в отдельных случаях 24%.

2019 ◽  
Vol 9 (10) ◽  
pp. 2009 ◽  
Author(s):  
Jiaming Han ◽  
Zhong Yang ◽  
Qiuyan Zhang ◽  
Cong Chen ◽  
Hongchen Li ◽  
...  

Insulator faults detection is an important task for high-voltage transmission line inspection. However, current methods often suffer from the lack of accuracy and robustness. Moreover, these methods can only detect one fault in the insulator string, but cannot detect a multi-fault. In this paper, a novel method is proposed for insulator one fault and multi-fault detection in UAV-based aerial images, the backgrounds of which usually contain much complex interference. The shapes of the insulators also vary obviously due to the changes in filming angle and distance. To reduce the impact of complex interference on insulator faults detection, we make full use of the deep neural network to distinguish between insulators and background interference. First of all, plenty of insulator aerial images with manually labelled ground-truth are collected to construct a standard insulator detection dataset ‘InST_detection’. Secondly, a new convolutional network is proposed to obtain accurate insulator string positions in the aerial image. Finally, a novel fault detection method is proposed that can detect both insulator one fault and multi-fault in aerial images. Experimental results on a large number of aerial images show that our proposed method is more effective and efficient than the state-of-the-art insulator fault detection methods.


2017 ◽  
Vol 10 (2) ◽  
pp. 221-230
Author(s):  
Judith Callanan

Purpose The purpose of this paper is to determine whether the discount placed on high voltage overhead transmission lines is underestimated. Design/methodology/approach A quantitative analysis was undertaken, using a high voltage overhead transmission line (HVOTL) case study, to determine the effect on property values prior and post removal of the HVOTL structure. Sales data and demographics are compared to determine the change in neighbourhood characteristics. Findings The results show that while the HVOTL is in place, the impact on value is confined to those properties in close proximity. This is in contradiction to the findings, where on removal of the HVOTL, the property values of the whole neighbourhood improve significantly. Research limitations/implications The implication of this research is that property valuers (appraisers) need to change the way they take into account the presence of HVOTLs when valuing property, with more emphasis, being placed on the neighbourhood rather than just the properties in close proximity. While the HVOTL was in place, only properties in close proximity were negatively affected, but on removal of the HVOTL the whole neighbourhood increased in value. Originality/value Results expand on current knowledge by demonstrating the difference between the discount rate that the valuers apply to the presence of the HVOTL, as compared to the positive impact to the whole neighbourhood on removal of the HVOTL.


2020 ◽  
Vol 1486 ◽  
pp. 062024
Author(s):  
Xiaoming Xiao ◽  
Weinan Hu ◽  
Jun Ran ◽  
Zheng Xu ◽  
Guoyu Hei ◽  
...  