scholarly journals Short-term Repeat Magnetic Resonance Imaging Scans in Suspected Early Axial Spondyloarthritis Are Clinically Relevant Only in HLA-B27–positive Male Subjects

2017 ◽  
Vol 45 (2) ◽  
pp. 202-205 ◽  
Author(s):  
Raj Sengupta ◽  
Helena Marzo-Ortega ◽  
Dennis McGonagle ◽  
Alison Wadeley ◽  
Alexander N. Bennett ◽  
...  

Objective.Our study investigated the natural history of magnetic resonance imaging (MRI)–determined bone marrow edema over a 12-week period in individuals with suspected axial spondyloarthritis.Methods.There were 109 MRI scans performed on 30 patients who fulfilled the Assessment of Spondyloarthritis international Society inflammatory back pain criteria at baseline and at 4, 8, and 12 weeks.Results.There were 29 patients who completed the study. Only 4 (14%) patients changed from MRI-negative to MRI-positive (all HLA-B27–positive, OR 2.74). Three of 7 (43%) male HLA-B27–positive patients, 1 of 8 (12.5%) HLA-B27–positive female patients, and no HLA-B27–negative patients changed from MRI- negative to -positive.Conclusion.Repeat MRI scans within a 12-week period should be considered in HLA-B27–positive males.

2019 ◽  
Vol 1 ◽  
pp. 2-6
Author(s):  
Asad Naqvi ◽  
Timothy Ariyanayagam ◽  
Mir Akber Ali ◽  
Akhila Rachakonda ◽  
Hema N. Choudur

Objective: The objective of this study was to outline a novel unique concept of secondary impingement of the muscles, myotendons, and tendons of the rotator cuff from hypertrophy as a result of strength training exercises. Methods: In this retrospective observational study, 58 patients were referred for an magnetic resonance imaging (MRI) by the orthopedic surgeon to the radiology department over a period of 1½ years. All patients gave a history of strength training exercises and presented with clinical features of rotator cuff impingement. Results: We identified features of hypertrophy of rotator cuff muscles, myotendons, and tendons in 12 of these 58 patients. This was the only abnormality on MRI. The hypertrophy of rotator cuff muscles and tendon bulk completely filling the subacromial space to the point of overfilling and resulting in secondary compressive features. Conclusion: Rotator cuff impingement is a common phenomenon that can occur with various inlet and outlet pathological conditions. However, rotator cuff impingement may also result from muscle and tendon hypertrophy from strength training regimens. Hypertrophy of the rotator cuff can result in overfilling of the subacromial space, leading to secondary impingement, which we have termed as “pseudo-impingement.”


Author(s):  
Hongzhang Zhu ◽  
Shi-Ting Feng ◽  
Xingqi Zhang ◽  
Zunfu Ke ◽  
Ruixi Zeng ◽  
...  

Background: Cutis Verticis Gyrata (CVG) is a rare skin disease caused by overgrowth of the scalp, presenting as cerebriform folds and wrinkles. CVG can be classified into two forms: primary (essential and non-essential) and secondary. The primary non-essential form is often associated with neurological and ophthalmological abnormalities, while the primary essential form occurs without associated comorbidities. Discussion: We report on a rare case of primary essential CVG with a 4-year history of normal-colored scalp skin mass in the parietal-occipital region without symptom in a 34-year-old male patient, retrospectively summarizing his pathological and Computer Tomography (CT) and magnetic resonance imaging (MRI) findings. The major clinical observations on the CT and MR sectional images include a thickened dermis and excessive growth of the scalp, forming the characteristic scalp folds. With the help of CT and MRI Three-dimensional (3D) reconstruction techniques, the characteristic skin changes could be displayed intuitively, providing more evidence for a diagnosis of CVG. At the 5-year followup, there were no obvious changes in the lesion. Conclusion: Based on our observations, we propose that not all patients with primary essential CVG need surgical intervention, and continuous clinical observation should be an appropriate therapy for those in stable condition.


Pain Practice ◽  
2021 ◽  
Author(s):  
Marco Reining ◽  
Dirk Winkler ◽  
Joachim Boettcher ◽  
Juergen Meixensberger ◽  
Michael Kretzschmar

Author(s):  
Cheng-Yi Wang ◽  
Wei-Chou Chang ◽  
Hsin-Hung Huang ◽  
Wei-Kuo Chang ◽  
Yu-Lueng Shih ◽  
...  

Objective: Not all endoscopic clips are compatible with magnetic resonance imaging (MRI). The aim of this study is to investigate the safety of MRI-incompatible endoscopic clips in patients undergoing MRI scans. Methods: We retrospectively reviewed the medical records of patients who had received endoscopic clip placement of Olympus Long Clip MRI-incompatible clips and then had undergone MRI scans within two weeks in our hospital between 2014 and 2019. Results: A total of 44,292 patients had undergone an MRI examination at our hospital. Only 15 patients had MRI scans within two weeks after the endoscopic clip placement. Their median age was 65.5 years, and 12 of the 15 patients were men. At the time of the clip placement and MRI scan, four patients were taking anti-coagulation or anti-platelet agents. The indication for endoscopic clip placement of the 15 patients was mucosal/submucosal defect or hemorrhage and colonic perforation. Endoscopic clips were placed in the colon of 14 patients and in the stomach of only one patient for gastric hemorrhage. One patient experienced clip migration and three displayed artifacts in abdominal images. No patient complications of mortality, hemorrhage, or organ perforation occurred. Conclusion: No serious adverse event occurred during MRI scans of patients with MRI-incompatible clips in this study, suggesting that MRI-incompatible clips may be safe to use in MRI scans. However, this does not guarantee the safety of the Long Clip for MRI scans, as further tests are needed to verify that this clip is safe for use during MRI.


Hand ◽  
2022 ◽  
pp. 155894472110643
Author(s):  
Jimmy H. Daruwalla ◽  
Jan Skrok ◽  
Mitchell A. Pet ◽  
Aviram M. Giladi ◽  
James P. Higgins

Background: The medial femoral trochlea (MFT) osteochondral flap is employed for reconstruction of unsalvageable scaphoid proximal pole nonunions. The convex surface of the cartilage-bearing proximal trochlea is used to replace the similarly contoured proximal scaphoid and articulate with the concave scaphoid fossa of the radius. A magnetic resonance imaging (MRI) comparison of the shape of the MFT as it relates to the native proximal scaphoid has not been previously performed. Our study aimed to quantifiably compare the shape of the MFT, proximal scaphoid, and scaphoid fossa. Methods: Using imaging processing software, we measured radius of curvature of the articular segments in MRI scans of 10 healthy subjects’ wrists and knees. Results: Compared with the scaphoid fossa, average ratio of the radius of circumference of the proximal scaphoid was 0.79 and 0.78 in the coronal and sagittal planes, respectively. Compared with the scaphoid fossa, average ratio of the radius of circumference of the MFT was 0.98 and 1.31 in the coronal and sagittal planes, respectively. The radius of curvature of the MFT was larger than the proximal scaphoid, in the coronal and sagittal planes. In the coronal plane, the MFT radius of curvature is nearly identical to the scaphoid fossa, a closer match than the scaphoid itself. In the sagittal plane, the radius of curvature of the MFT was larger than the radius of curvature of the scaphoid fossa. Conclusions: Our data suggest that the radius of curvature, in the sagittal and coronal planes, of the MFT and proximal scaphoid is disparate.


2019 ◽  
Vol 46 (11) ◽  
pp. 1445-1449 ◽  
Author(s):  
Xenofon Baraliakos ◽  
Florian Hoffmann ◽  
Xiaohu Deng ◽  
Yan-Yan Wang ◽  
Feng Huang ◽  
...  

Objective.The volumetric interpolated breath-hold examination (VIBE) magnetic resonance imaging (MRI) technique can visualize erosive cartilage defects in peripheral joints. We evaluated the ability of VIBE to detect erosions in sacroiliac joints (SIJ) of patients with axial spondyloarthritis (axSpA) compared to the established T1-weighted MRI sequence and computed tomography (CT).Methods.MRI (T1-weighted and VIBE) and CT scans of SIJ of 109 patients with axSpA were evaluated by 2 blinded readers based on SIJ quadrants (SQ). Erosions were defined according to Assessment of Spondyloarthritis international Society (ASAS) definitions. Scores were recorded if readers were in agreement.Results.Erosions were less frequently detected by CT (153 SQ) than by T1-weighted MRI (182 SQ; p = 0.008) and VIBE-MRI (199 SQ; p < 0.001 vs CT and p = 0.031 vs T1-weighted MRI). Taking CT as the gold standard, the sensitivity of VIBE-MRI (71.2%) was higher than that for T1-weighted MRI (63.4%), with similar specificity (87.3% vs 88%, respectively). In linear regression analysis, younger age was significantly associated with occurrence of erosions independently in VIBE-MRI (β = 0.384, p < 0.001) and T1-weighted MRI (β = 0.369, p < 0.001) compared to CT.Conclusion.The VIBE-MRI sequence was more sensitive than T1-weighted MRI in identifying erosive damage in the SIJ, especially in younger patients. This might be due to the ability of VIBE-MRI to identify structural changes in the cartilage that have not yet extended to the underlying bone, where CT seems to be superior.


2008 ◽  
Vol 90 (1) ◽  
pp. 25-28 ◽  
Author(s):  
S Blyth ◽  
A Blakeborough ◽  
M Peterson ◽  
IC Cameron ◽  
AW Majeed

INTRODUCTION The aim of this study was to evaluate the sensitivity of magnetic resonance imaging (MRI) in the detection of colorectal liver metastases. PATIENTS AND METHODS Pre-operative MRI scanning of the liver was performed by a single radiologist and the size and number of definite liver metastases were recorded. Patients then underwent hepatectomy with routine intra-operative ultrasonography (IOUS) and resected specimens were sent for histopathology. Pathology findings were compared with those of MRI scans to determine the sensitivity of this imaging modality. Exclusions were patients undergoing hepatic resection more than 4 weeks after the MRI scan, those undergoing chemotherapy at the time of the scan, and those with conglomerate unilobar metastases. RESULTS Complete data were available for 84 patients. There was total agreement between MRI, IOUS and histology in 79 patients (101 metastases). MRI missed 5 metastases in 5 patients that were found on IOUS (or palpation of superficial lesions) and subsequently confirmed by histological examination. These measured 5 mm or less (4 patients) and 7 mm (one patient). The sensitivity of MRI in the detection of colorectal liver metastases was thus 94% for all lesions and 100% for lesions 1 cm or larger in diameter. CONCLUSIONS MRI of the liver is a non-invasive technique with an extremely high degree of sensitivity in the detection of colorectal liver metastases and should be considered as the ‘gold standard’ in the pre-operative imaging of these patients.


Sign in / Sign up

Export Citation Format

Share Document