Optimization of the Ventilation System for a Forced Ventilation Piggery

2009 ◽  
Vol 4 (4) ◽  
pp. 113-133
Author(s):  
R. R Mossad

Pigs are subjected to intensive environment control and management in order to achieve higher productivity. This is due to their sensitivity to climatic variation, which strongly affects their growth. This paper reports the design optimization of a forced ventilation piggery using computational fluid dynamics. This numerical investigation determined the effect of varying the number of ventilation openings and their location on the air flow pattern, speed, temperature, power needed, ability to remove heat and residence time. The effect of varying the ventilation rate in a range (0.05 – 0.8 m3/s), and ambient temperatures of 5°C and 32°C was also investigated. The modeled piggery has dimensions 40 m × 15 m × 2.6 m, with central walkway and gable roof with the apex at 3.9 m and is a common design in Australia. A steady-state two-dimensional numerical model based on the integral volume method, including the effects of buoyancy and heat generated by the pigs, was solved using the computational fluid dynamics software “Fluent.” Four designs were investigated and an optimum design, which facilitates better ventilation of the majority of the room, has been identified. In summer, an inlet velocity has been recommended which achieves optimum environment inside the piggery meeting the pigs' thermal comfort criteria with minimum power usage. During winter it became obvious that heating has to be used in all designs to be able to meet the pigs' thermal comfort criteria.

2001 ◽  
Author(s):  
Ruth Mossad

Abstract Pigs are subjected to intensive environment control and management for higher productivity due to their sensitivity to climatic variation, which affects their growth. The aim of the current work is to numerically model the air speed and temperature in forced and free ventilation piggeries to achieve optimum environmental control. A steady two-dimensional numerical model including the effect of buoyancy, turbulence and heat generated by the pigs was solved using the computational fluid dynamics software Fluent, which is based on the integral volume method. In the forced ventilation case, air speed and temperature inside the piggery and at the pigs’ level were predicted for three different locations of ventilation opening, variable air inlet velocities (in the range 0.3 m/s – 7 m/s), and insulated or non insulated external walls, for ambient temperatures of 5 °C and 32 °C. In the free ventilation case, temperature and air speed at the pig’s level were predicted for a particular wind speed and direction, and some variations in the design. These variations were adding louvers in the air opening, lowering the outer wall of the piggery and changing the type of pen fence used. These results helped to identify problems in the design and offer suggestions for improvements.


Animals ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 2352
Author(s):  
Long Chen ◽  
Eileen E. Fabian-Wheeler ◽  
John M. Cimbala ◽  
Dan Hofstetter ◽  
Paul Patterson

This work investigated alternative ventilation schemes to help define a proper ventilation system design in cage-free hen houses with the goal of assuring bird welfare through comfortable conditions. Computational fluid dynamics (CFD) modeling was employed to simulate indoor and outdoor airflows to quantify the effectiveness of ventilation systems in maintaining suitable and uniform living conditions at the hen level. Four three-dimensional CFD models were developed based on a full-scale floor-raised layer house, corresponding to ventilation schemes of the standard top-wall inlet, sidewall exhaust, and three alternatives: mid-wall inlet, ceiling exhaust; mid-wall inlet, ridge exhaust; and mid-wall inlet, attic exhaust with potential for pre-treatment of exhaust air. In a sophisticated and powerful achievement of the analysis, 2365 birds were individually modeled with simplified bird-shapes to represent a realistic number, body heat, and airflow obstruction of hens housed. The simulated ventilation rate for the layer house models was 1.9–2.0 m3/s (4100 ft3/min) in the desired range for cold weather (0 °C). Simulation results and subsequent analyses demonstrated that these alternative models had the capacity to create satisfactory comfortable temperature and air velocity at the hen level. A full-scale CFD model with individual hen models presented robustness in evaluating bird welfare conditions.


2014 ◽  
Vol 493 ◽  
pp. 74-79
Author(s):  
Y.A. Sabtalistia ◽  
S.N.N. Ekasiwi ◽  
B. Iskandriawan

Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too.This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation.This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.