Research on a New Type of Electric Energy Meter Charged Detection Terminal Box

2013 ◽  
Vol 278-280 ◽  
pp. 220-224 ◽  
Author(s):  
Ying Ying Cheng ◽  
Hua Xiao Yang ◽  
Ji Xiao

Aiming at the field live detection of the electric energy meter, the research on the new structure and the charged detection method of the terminal boxes were carried out. The results can be directly applied to the charged detection of the electric energy metering device, which can improve work efficiency and security. It has great significance to ensure that the electric energy metering device of the power system can operate safely, stably and economically.

2014 ◽  
Vol 644-650 ◽  
pp. 3639-3642
Author(s):  
Xing Zhe Hou ◽  
Hui Yan ◽  
Ling Feng ◽  
Dong Wei

The new type lead sealing of aluminum alloy designed and manufactured by an electric energy meter packaged on the spot, has the excellent characteristics of anti-counterfeiting,anti-pry, and good anti-electric larcenies.


2013 ◽  
Vol 278-280 ◽  
pp. 998-1004
Author(s):  
Ji Xiao ◽  
Ying Ying Cheng ◽  
Juan Tian

For the sake of real-time online monitoring the operating state and parameters of electric energy metering devices, detecting the abnormal states of devices, predicting the trend of electric energy metering device error, and changing the traditional management mode for electric energy metering devices, which adopts the cycle test rotation mechanism, this paper has proposed a state management system of electric energy metering device based on NI CompactRIO platform. The proposed system can implement real-time online management for monitoring the measurement error of electric energy meter, data acquisition of electric energy meter, test of Secondary Voltage Drop and Secondary Load of PT, test of Secondary Load of CT, video monitoring, measurement of temperature humidity, measurement of space magnetic, etc. The system combines CompactRIO platform and electric energy metering devices to acquire, monitor and analyze the real-time online data corresponding to electric energy meter, CT, PT and secondary loop. And the Energy metering error and the evaluation of parameters of electric energy metering device are calculated by the CPU, and the data is exchanged with the remote station by communication network. So the system improves the management efficiency and benefits of electric energy metering devices.


2014 ◽  
Vol 700 ◽  
pp. 88-93 ◽  
Author(s):  
Hao Chen ◽  
Zhi Kun Luo ◽  
Chao Long Ou ◽  
Fu Sheng Chen ◽  
Jie Xiang ◽  
...  

This paper presents a power consumption model with harmonics existing in power system, the influence of harmonic linear load and the influence of nonlinear load energy metering is discussed, then the analysis of the impact of the harmonic of induction watt-hour meter and electronic watt-hour meter measurement features is given. In the next part, the measurement principle of harmonic watt-hour meter is introduced, and a new type of electric energy metering scheme based on harmonic watt-hour meter is given, so that the electric energy metering fairness problem caused by power grid harmonic will be solved effectively.


2013 ◽  
Vol 278-280 ◽  
pp. 994-997
Author(s):  
San Qiang Wang ◽  
Xing Zhe Hou ◽  
Yan Lin Liu ◽  
Qiu Hui Zhuang

With the progress of science and technology, electronic type electric energy meter is widely used in electric energy metering and charging in China, especially in rural power network reform, investment, electronic type electric energy meter with its linearity, stability is good, the power consumption of small, voltage and frequency response speed, high measurement precision, to further improve the market share, but how to test electronic type electric energy meter, but has been puzzling the test technical staff, according to the practical experience on the above problem undertakes a few discuss. This paper analyzes the electronic type electric energy meter principle, characteristics, focus on the research of the electric energy meter calibration method, the electronic type electric energy meter calibrating idea and train of thought.


Author(s):  
Yongping Liu ◽  
Chuanliang He ◽  
Xin Xia ◽  
Yingjie Lv ◽  
Shouzhi Wang ◽  
...  

2013 ◽  
Vol 834-836 ◽  
pp. 1246-1250
Author(s):  
Hai Bo Yu ◽  
Jia Liu ◽  
Chun Yu Wang ◽  
Li Li ◽  
Rui Ming Tong

The verification of electronic type electric energy meter is under strict reference conditions, but some special operating conditions at locale will exceed the standard scopes. In order to improve the calculation accuracy and operating reliability of electric energy meter under operating conditions, it is necessary to study the operating conditions. According to the working principle and the standard verification regulation of electronic type electric energy meter, this paper summarizes these operating conditions: low power factor, harmonic waves, dynamic impulsive load, voltage fluctuation and outside magnetic field of power frequency, then analyzes the causes of operating conditions and their influence on electronic type electric energy meter, eventually lays foundation for thorough and systematic study of electric energy meter in the operating conditions, and establishes measurement center database of operating conditions.