Optimization of Indirect Air-Cooling System of Power Plants with Incremental Power Generation Method and Coal Consumption Method

2013 ◽  
Vol 341-342 ◽  
pp. 1250-1253
Author(s):  
Wen Zhou Yan ◽  
Bo Yang

The indirect air-cooling system is usually optimized for minimum annual cost. Domestic designing departments take different views on incremental power generation method and coal consumption method in calculation of operating cost. This paper analyzed the two different methods by using the optimization software of indirect air-cooling system, and modified the main parameters of indirect air-cooling system in practical engineering. In this paper, annual cost is in 10 thousand Yuan.

2015 ◽  
Vol 76 ◽  
pp. 449-461 ◽  
Author(s):  
Mehdi A. Ehyaei ◽  
Mojtaba Tahani ◽  
Pouria Ahmadi ◽  
Mohammad Esfandiari

Author(s):  
Motoaki Utamura ◽  
Yoshio Nishimura ◽  
Akira Ishikawa ◽  
Nobuo Ando

A cost estimate method is presented, which enables to compare inlet air cooling system for power enhancement of combustion turbine with other power generation system. A new energy conversion index is developed which arranges system design parameters in a dimensionless form and also exhibits running cost. It is suggested that the inlet air cooling system is equivalent to simple cycle or pumped storage in view of the dimensionless running cost. Next, a cost diagram relating capital cost to power generation cost is presented also in non-dimensional form, which could provide a measure to examine investment worth for a power producer. Moreover, cooling effectiveness as function of cooled inlet air temperature is investigated using specific thermal energy. It is revealed that cooling beyond dew point requires a larger thermal energy per electric energy produced and thus less economical unless the price of electricity depends on electricity demand.


2018 ◽  
Vol 225 ◽  
pp. 01020
Author(s):  
Thamir K. Ibrahim ◽  
Mohammed K. Mohammed ◽  
Omar I. Awad ◽  
Rizalman Mamat ◽  
M. Kh Abdolbaqi

A basic goal of operation management is to successfully complete the life cycle of power systems, with optimum output against minimal input. This document intends calculating both, the performance and the life cycle cost of a gas turbine fitted with an inlet air cooling mechanism. Correspondingly, both a thermodynamic and an economic model are drawn up, to present options towards computing the cooling loads and the life cycle costs. The primary observations indicate that around 120MWh of power is derived from gas turbine power plants incorporating the cooling mechanism, compared to 96.6 MWh for units without the mechanism, while the life cycle cost is lower for units incorporating the cooling process. This indicates benefits in having the mechanism incorporated in the architecture of a gas turbine.


Author(s):  
Hiroyuki Yamazaki ◽  
Yoshiaki Nishimura ◽  
Masahiro Abe ◽  
Kazumasa Takata ◽  
Satoshi Hada ◽  
...  

Tohoku Electric Power Company, Inc. (Tohoku-EPCO) has been adopting cutting-edge gas turbines for gas turbine combined cycle (GTCC) power plants to contribute for reduction of energy consumption, and making a continuous effort to study the next generation gas turbines to further improve GTCC power plants efficiency and flexibility. Tohoku-EPCO and Mitsubishi Hitachi Power Systems, Ltd (MHPS) developed “forced air cooling system” as a brand-new combustor cooling system for the next generation GTCC system in a collaborative project. The forced air cooling system can be applied to gas turbines with a turbine inlet temperature (TIT) of 1600deg.C or more by controlling the cooling air temperature and the amount of cooling air. Recently, the forced air cooling system verification test has been completed successfully at a demonstration power plant located within MHPS Takasago Works (T-point). Since the forced air cooling system has been verified, the 1650deg.C class next generation GTCC power plant with the forced air cooling system is now being developed. Final confirmation test of 1650deg.C class next generation GTCC system will be carried out in 2020.


Author(s):  
Nicola Palestra ◽  
Giovanna Barigozzi ◽  
Antonio Perdichizzi

Investigation results of compressor inlet air boosting and cooling, applied to combined cycle power plants, are presented and discussed. Gas turbine performances may be reduced by site altitude and inlet losses due to air ducts and filters. Increasing inlet pressure by fans allows the restoring of gas turbine power output and efficiency at least to ISO reference conditions. Coupling such a system with inlet air cooling may completely suppress the temperature increase given by inlet air compression and the pressure losses through air coils as well; therefore, by this way, a further increase of electric energy production can be achieved. An in-house simulation code, developed for evaluating inlet air cooling system performance by cool thermal storage, has been adapted in order to also simulate off-design behaviour of boosting applied to combined cycle plants. A 127 MW reference power plant, operating in the Italian scenario, has been considered. Inlet pressure increase has been evaluated with and without inlet cooling, and in comparison with inlet cooling solution alone. Both thermodynamic and economical results have been analyzed. A parametric analysis on both system sizing parameters has been carried out. Best solution was found in coupling boosting to inlet cooling system through cool thermal storage; it produced an important increase in electric energy production. Location site influence on investment pay-back proved to be less important compared to the solution with inlet air cooling system alone.


2021 ◽  
Vol 09 (03) ◽  
pp. E482-E486
Author(s):  
Stanislas Chaussade ◽  
Einas Abou Ali ◽  
Rachel Hallit ◽  
Arthur Belle ◽  
Maximilien Barret ◽  
...  

Abstract Background and study aims The role that air circulation through a gastrointestinal endoscopy system plays in airborne transmission of microorganisms has never been investigated. The aim of this study was to explore the potential risk of transmission and potential improvements in the system. Methods We investigated and described air circulation into gastrointestinal endoscopes from Fujifilm, Olympus, and Pentax. Results The light source box contains a lamp, either Xenon or LED. The temperature of the light is high and is regulated by a forced-air cooling system to maintain a stable temperature in the middle of the box. The air used by the forced-air cooling system is sucked from the closed environment of the patient through an aeration port, located close to the light source and evacuated out of the box by one or two ventilators. No filter exists to avoid dispersion of particles outside the processor box. The light source box also contains an insufflation air pump. The air is sucked from the light source box through one or two holes in the air pump and pushed from the air pump into the air pipe of the endoscope through a plastic tube. Because the air pump does not have a dedicated HEPA filter, transmission of microorganisms cannot be excluded. Conclusions Changes are necessary to prevent airborne transmission. Exclusive use of an external CO2 pump and wrapping the endoscope platform with a plastic film will limit scatter of microorganisms. In the era of pandemic virus with airborne transmission, improvements in gastrointestinal ventilation systems are necessary to avoid contamination of patients and health care workers.