Volume 4: Heat Transfer; Electric Power; Industrial and Cogeneration
Latest Publications


TOTAL DOCUMENTS

108
(FIVE YEARS 0)

H-INDEX

11
(FIVE YEARS 0)

Published By American Society Of Mechanical Engineers

9780791878750

Author(s):  
S. Neelakantan ◽  
M. E. Crawford

A new model is developed to predict laterally-averaged film cooling. At the injection location, the near-hole region is leapt over and the injectant is distributed according to an existing jet in cross flow model and experimental data. The subsequent dispersion of the injectant is simulated to reflect the augmented mixing and the 3-dimensionality of the flow field. The new model is calibrated to predict effectiveness and heat transfer using the experimental data bases of Schmidt et al. (1994), Sen et al. (1994), Kohli et al. (1994), and Sinha et al. (1991). The geometries include injection angles of 35° and 55° with compound angles of 0° and 60° and hole spacings of 3 and 6 diameters. The new model yields improved effectiveness predictions over previous 2-D models.


Author(s):  
Hideo Kobayashi ◽  
Shogo Tsugumi ◽  
Yoshio Yonezawa ◽  
Riuzou Imamura

IHI is developing a new heavy duty gas turbine engine for 2MW class co-generation plants, which is called IM270. This engine is a simple cycle and single-spool gas turbine engine. Target thermal efficiency is the higher level in the same class engines. A dry low NOx combustion system has been developed to clear the strictest emission regulation in Japan. All parts of the IM270 are designed with long life for low maintenance cost. It is planned that the IM270 will be applied to a dual fluid system, emergency generation plant, machine drive engine and so on, as shown in Fig.1. The development program of IM270 for the co-generation plant is progress. The first prototype engine test has been started. It has been confirmed that the mechanical design and the dry low NOx system are practical. The component tuning test is being executed. On the other hand, the component test is concurrently in progress. The first production engine is being manufactured to execute the endurance test using a co-generation plant at the IHI Kure factory. This paper provides the conceptual design and status of the IM270 basic engine development program.


Author(s):  
Motoaki Utamura ◽  
Yoshio Nishimura ◽  
Akira Ishikawa ◽  
Nobuo Ando

A cost estimate method is presented, which enables to compare inlet air cooling system for power enhancement of combustion turbine with other power generation system. A new energy conversion index is developed which arranges system design parameters in a dimensionless form and also exhibits running cost. It is suggested that the inlet air cooling system is equivalent to simple cycle or pumped storage in view of the dimensionless running cost. Next, a cost diagram relating capital cost to power generation cost is presented also in non-dimensional form, which could provide a measure to examine investment worth for a power producer. Moreover, cooling effectiveness as function of cooled inlet air temperature is investigated using specific thermal energy. It is revealed that cooling beyond dew point requires a larger thermal energy per electric energy produced and thus less economical unless the price of electricity depends on electricity demand.


Author(s):  
Vasco Mezzedimi ◽  
Pierluigi Nava ◽  
Dave Hamilla

The full mapping of a new gas turbine axial compressor at different speeds, IGV settings and pressure ratios (from choking to surge) has been performed utilizing a complete gas turbine with a suitable set of modifications. The main additions and modifications, necessary to transform the turbine into the Compressor Test Vehicle (CTV), are: - Compressor inlet throttling valve addition - Compressor discharge bleed valve addition - Turbine 1st stage nozzle area reduction - Starting engine change (increase in output and speed range). This method has been successfully employed on two different single shaft heavy-duty gas turbines (with a power rating of 11MW and 170 MW respectively). The paper describes the theoretical basis of this testing method and a specific application with the above mentioned 170 MW machine.


Author(s):  
Donald L. Schmidt ◽  
David G. Bogard

A flat plate test section was used to study how high free-stream turbulence with large turbulence length scales, representative of the turbine environment, affect the film cooling adiabatic effectiveness and heat transfer coefficient for a round hole film cooling geometry. This study also examined cooling performance with combined high free-stream turbulence and a rough surface which simulated the roughness representative of an in-service turbine. The injection was from a single row of film cooling holes with injection angle of 30°. The density ratio of the injectant to the mainstream was 2.0 for the adiabatic effectiveness tests, and 1.0 for the heat transfer coefficient tests. Streamwise and lateral distributions of adiabatic effectiveness and heat transfer coefficients were obtained at locations from 2 to 90 hole diameters downstream. At small to moderate momentum flux ratios, which would normally be considered optimum blowing conditions, high free-stream turbulence dramatically decreased adiabatic effectiveness. However, at large momentum flux ratios, conditions for which the film cooling jet would normally be detached, high free-stream turbulence caused an increase in adiabatic effectiveness. The combination of high free-stream turbulence with surface roughness resulted in an increase in adiabatic effectiveness relative to the smooth wall with high free-stream turbulence. Heat transfer rates were relatively unaffected by a film cooling injection. The key result from this study was a substantial increase in the momentum flux ratios for maximum film cooling performance which occurred for high free-stream turbulence and surface roughness conditions which are more representative of actual turbine conditions.


Author(s):  
David T. Ryan ◽  
Judith A. Veatch ◽  
Akber Pasha

‘Soft’ start flow distribution, control capability, sealing performance, and safety, were four reasons Oklahoma Municipal Power Authority (OMPA), in cooperation with Black & Veatch and Vogt, installed Dual BiPlane Heat Recovery Steam Generator (HRSG) Isolation and Bypass Dampers from Damper Design, Inc. on the gas turbine outlet at this facility. The DDI BiPlane damper is truly a unique damper for this application. This design allowed OMPA to have the safety and isolation of a flap diverter white providing the even gas distribution and accurate flow control to the HRSG under startup conditions available from a louver style damper. The arrangement consists of two DDI BiPlane dampers, one on the inlet to the HRSG and one isolating the stack. Since safety is highest priority, Damper Design utilized an independent lockout type linkage that allows control of the dampers while positively preventing the closure of both gas paths at the same time. By installing the DDI BiPlane damper, OMPA has the ability to throttle the gas turbine exhaust flow independently to the HRSG and stack. This allows the gases to enter the HRSG with a much more evenly distributed flow pattern and at lower controlled flow rates than with competing designs. This paper will address the benefits, design, and operating advantages of the use of the DDI BiPlane Damper specifically in HRSG isolation and bypass installations. It is also applicable to other systems where control and isolation with one damper is desirable.


Author(s):  
J. Richter ◽  
K. Jung ◽  
D. K. Hennecke

The dependence of heat transfer on film cooling near the leading edge of a blade was investigated using the naphthalene sublimation technique and applying the analogy between heat and mass transfer. Therefore, the local sublimation rate with and without film cooling was measured. The symmetric leading edge was cooled by an air mass flow out of two staggered rows of holes. The measurements were carried out with a constant Reynolds number Re = 80000, different incidence angles φ = 0° to 10° and a blowing rate varying from M = 0.3 to 2.5. The flow without film cooling was visualized around the leading edge with smoke to indicate the existence of separation bubbles. To determine the dependence of incidence angle and blowing rate on jet trajectories, smoke was mixed to the cooling air. The mass transfer coefficient was determined with the naphthalene sublimation technique. Due to the high resolution of the sublimation technique the local mass transfer distribution around the cooling holes could also be measured. Furthermore, the location of stagnation points and separation bubbles were investigated. The results of the tests without film cooling were also compared with those obtained by observing stagnation point mass transfer on a cylinder and with those by laminar flow across a flat plate. The mass transfer coefficient of film cooling experiments was related to the mass transfer coefficient without film cooling to describe the local dependence of heat transfer coefficient on film cooling. An increase on relativ heat transfer near the film cooling holes is obtained by increasing the blowing rate. No further influence on heat transfer along the pressure side is detected for an incidence angle larger than 10° as the cooling films were shifted around the leading edge from the pressure to the suction side.


Author(s):  
Rainer Höcker

An analytical investigation has been made to identify and quantify critical parameters influencing the final result of a transient heat transfer experiment. The aim was to obtain a set of dimensionless parameters, that describe the interaction of the individual measured quantities in a compact form. Among the wide variety of different kinds of heat transfer measurement techniques, the transient method, employing thermochromic liquid crystals, is very useful. It gives much detailed heat transfer information with a minimum effort in experimental time. The present paper focuses on this technique, although it is not the only choice for all kinds of applications, but it is the currently most frequently used one. This paper provides the means to lay out an experiment, so that it yields acceptable results with respect to the constraints for a set of test boundary conditions.


Author(s):  
Pingfan He ◽  
Dragos Licu ◽  
Martha Salcudean ◽  
Ian S. Gartshore

The effect of varying coolant density on film cooling effectiveness for a turbine blade-model was numerically investigated and compared with experimental data. This model had a semi-circular leading edge with four rows of laterally-inclined film cooling orifices positioned symmetrically about the stagnation line. A curvilinear coordinate-based CFD code was developed and used for the numerical investigation. The code used a domain segmentation strategy in conjunction with general curvilinear grids to model the complex blade configuration. A multigrid method was used to accelerate the convergence rate. The time-averaged, variable-density, Navier-Stokes equations together with the energy or scalar equation were solved. Turbulence closure was attained by the standard k–ε model with a near-wall k model. Either air or CO2 was used as coolant in three cases of injection through single rows and alternatively staggered double raws of holes. Two different blowing rates were investigated in each case and compared with experimental data. The experimental results were obtained using a wind tunnel model, and the mass/heat analogy was used to determine the film cooling effectiveness. The higher density of the carbon dioxide coolant (approximately 1.5 times the density of air) in the isothermal mass injection experiments, was used to simulate the effects of injection of a colder air in the corresponding adiabatic heat transfer situation. Good agreement between calculated and measured film cooling effectiveness was found for low blowing ratio M ≤ 0.5 and the effect of density was not significant. At higher blowing ratio M > 1 the calculations consistently overpredict the measured values of film cooling effectiveness.


Author(s):  
Xueyou Wen ◽  
Jiguo Zou ◽  
Zheng Fu ◽  
Shikang Yu ◽  
Lingbo Li

Steam-injected gas turbines have a multitude of advantages, but they suffer from the inability to recover precious demineralized water. The present paper describes the test conditions and results of steam injection along with an attempt to achieve water recovery, which were obtained through a series of tests conducted on a S1A-02 small-sized industrial gas turbine. A water recovery device incorporating a compact finned spiral plate cooling condenser equipped with filter screens has been designed for the said gas turbine and a 100% water recovery (based on the design point) was attained.


Sign in / Sign up

Export Citation Format

Share Document