Research on Mass Determination of International Comparison CCM.M-K4 of 1 kg Mass Weights

2015 ◽  
Vol 742 ◽  
pp. 75-79
Author(s):  
Man Hong Hu ◽  
Jian Wang ◽  
Yue Zhang ◽  
Chang Qing Cai ◽  
Rui Lin Zhong ◽  
...  

CCM.M-K4 is a key international comparison organized by the Bureau International des Poids et Mesures (BIPM) to verify the measurement ability of 1kg stainless weights. This paper reports the process analysis of mass determination of CCM.M-K4 during the measurement in NIM, China. The gravity correction and air bouncy correction are discussed, and the measuring uncertainties of measurement process are evaluated. Mass difference between the test standards is 0.0015 mg, and average mass of both test standards is 0.013 mg. The standard uncertainty of test weights is 0.013 mg.

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Evamaria C. Gaugler ◽  
Wolfgang Radke ◽  
Andrew P. Vogt ◽  
Dawn A. Smith

AbstractMolar masses, Mark-Houwink-Sakurada (MHS) exponents, and refractive index increments (dn/dc) for three lignins were determined without derivatization by multi-detector gel permeation chromatography (GPC) in dimethylformamide (DMF) with 0.05 M lithium bromide (LiBr). The lack of effectiveness of fluorescence filters on molar mass determination by GPC-multi-angle laser light scattering (MALS) was confirmed for softwood kraft lignin (Indulin AT) and revealed for mixed hardwood organosolv lignin (Alcell) as well as soda straw/grass lignin (Protobind 1000). GPC with viscometry detection confirmed that these lignins were present as compact molecules. The MHS exponent α for Indulin AT and Alcell was in the order of 0.1. Additionally, the intrinsic viscosity of Protobind 1000 for a given molar mass was much lower than that of either Alcell or Indulin AT. This is the first report of dn/dc values for these three lignins in DMF with 0.05 M LiBr.


2018 ◽  
Vol 618 ◽  
pp. A116 ◽  
Author(s):  
J. Prieto-Arranz ◽  
E. Palle ◽  
D. Gandolfi ◽  
O. Barragán ◽  
E. W. Guenther ◽  
...  

Context. Multiplanet systems are excellent laboratories to test planet formation models as all planets are formed under the same initial conditions. In this context, systems transiting bright stars can play a key role, since planetary masses, radii, and bulk densities can be measured. Aims. GJ 9827 (K2-135) has recently been found to host a tightly packed system consisting of three transiting small planets whose orbital periods of 1.2, 3.6, and 6.2 days are near the 1:3:5 ratio. GJ 9827 hosts the nearest planetary system (~30 pc) detected by NASA’s Kepler or K2 space mission. Its brightness (V = 10.35 mag) makes the star an ideal target for detailed studies of the properties of its planets. Methods. Combining the K2 photometry with high-precision radial-velocity measurements gathered with the FIES, HARPS, and HARPS-N spectrographs we revised the system parameters and derive the masses of the three planets. Results. We find that GJ 9827 b has a mass of Mb = 3.69−0.46+0.48 M⊕ and a radius of Rb = 1.58−0.13+0.14 R⊕, yielding a mean density of ρb = 5.11−1.27+1.74 g cm−3. GJ 9827 c has a mass of Mc = 1.45−0.57+0.58 M⊕, radius of Rc = 1.24−0.11+0.11 R⊕, and a mean density of ρc = 4.13−1.77+2.31 g cm−3. For GJ 9827 d, we derive Md = 1.45−0.57+0.58 M⊕, Rd = 1.24−0.11+0.11 R⊕, and ρd = 1.51−0.53+0.71 g cm−3. Conclusions. GJ 9827 is one of the few known transiting planetary systems for which the masses of all planets have been determined with a precision better than 30%. This system is particularly interesting because all three planets are close to the limit between super-Earths and sub-Neptunes. The planetary bulk compositions are compatible with a scenario where all three planets formed with similar core and atmosphere compositions, and we speculate that while GJ 9827 b and GJ 9827 c lost their atmospheric envelopes, GJ 9827 d maintained its primordial atmosphere, owing to the much lower stellarirradiation. This makes GJ 9827 one of the very few systems where the dynamical evolution and the atmosphericescape can be studied in detail for all planets, helping us to understand how compact systems form and evolve.


Author(s):  
Nathan E. Flowers-Jacobs ◽  
Alessio Pollarolo ◽  
Kevin J. Coakley ◽  
Adam C. Weis ◽  
Anna E. Fox ◽  
...  

In preparation for the redefinition of the International System of Units (SI), five different electronic measurements of the Boltzmann constant have been performed using different Johnson noise thermometry (JNT) systems over the past seven years. In this paper, we describe in detail the JNT system and uncertainty components associated with the most recent National Institute of Standards and Technology (NIST) determination of the Boltzmann constant: k = 1.380642 9(69) × 10−23 J/K, with a relative standard uncertainty of 5.0 × 10−6 and relative offset of −4.05 × 10−6 from the Committee on Data for Science and Technology (CODATA) 2014 recommended value. We discuss the input circuits and the approach we used to match the frequency response of two noise sources. We present new measurements of the correlated noise of the 4 K on-chip resistors in the quantum-accurate, pseudorandom, voltage-noise source, which we used to estimate the correlated, frequency-dependent, nonthermal noise in our system. Finally, we contrast our system with those used in other measurements and speculate on future improvements.


Sign in / Sign up

Export Citation Format

Share Document