Frequency Domain Analysis and Application of Electrochemical Noise of X80 Pipeline Steel

2014 ◽  
Vol 1015 ◽  
pp. 659-662
Author(s):  
Peng Xin Feng ◽  
Wen Long Xu ◽  
Hai Tao Lai ◽  
Xun Zhu ◽  
Wen Wei Lu ◽  
...  

In this paper, frequency domain analysis and application of electrochemical noise of X80 Pipeline Steel in Xinzhou Soil is researched. In the frequency data analysis of electrochemical noise, there are three characteristic parameters. It can be seen from experiments that X80 steel buried in Xinzhou soil with14% moisture content shows that metal corrosion is still not change much. And, it can be inferred that corrosion of X80 pipeline steel in Xinzhou soil with 18% moisture, corrosion is uniform while the morphology is not the uniform , it is the morphology that some pitting are connecting into the film. In Xinzhou soil with 22% moisture, potential PSD figure is different after corrosion happened for one day and three days. Thus, the corrosion type can be determined by high-frequency slope of the linear segment of potential PSD figure.

Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3606
Author(s):  
Jing-Yuan Lin ◽  
Chuan-Ting Chen ◽  
Kuan-Hung Chen ◽  
Yi-Feng Lin

Three-phase wye–delta LLC topology is suitable for voltage step down and high output current, and has been used in the industry for some time, e.g., for server power and EV charger. However, no comprehensive circuit analysis has been performed for three-phase wye–delta LLC. This paper provides complete analysis methods for three-phase wye–delta LLC. The analysis methods include circuit operation, time domain analysis, frequency domain analysis, and state–plane analysis. Circuit operation helps determine the circuit composition and operation sequence. Time domain analysis helps understand the detail operation, equivalent circuit model, and circuit equation. Frequency domain analysis helps obtain the curve of the transfer function and assists in circuit design. State–plane analysis is used for optimal trajectory control (OTC). These analyses not only can calculate the voltage/current stress, but can also help design three-phase wye-delta connected LLC and provide the OTC control reference. In addition, this paper uses PSIM simulation to verify the correctness of analysis. At the end, a 5-kW three-phase wye–delta LLC prototype is realized. The specification of the prototype is a DC input voltage of 380 V and output voltage/current of 48 V/105 A. The peak efficiency is 96.57%.


2020 ◽  
Vol 53 (2) ◽  
pp. 13161-13166
Author(s):  
Henrik Alenius ◽  
Roni Luhtala ◽  
Tomi Roinila

2014 ◽  
Vol 1015 ◽  
pp. 655-658
Author(s):  
Shu Zhen Yu ◽  
Guang Jun Xu ◽  
Han Hua Song ◽  
Xun Zhu ◽  
Wen We Lu ◽  
...  

The electrochemical corrosion of X80 pipeline steel in Xinzhou’s soil with different water content is tested and analyzed. The corrosion signal time and frequency domain figure show that the corrosion signal fluctuates all the time in 30 days’ test with low water content (14%). The slope of high-frequency linear segment in the potential PSD is smaller than it is at the beginning. In the soil with the middle water content (18%), the intense wave motion lasts for 15 days. The noise fluctuation only exists before the third days when in the high water content soil (22%). After the third day, linear drift can be observed but no transient peak. The slope of high-frequency linear segment changes obviously compared with the situation in the beginning. And the high-frequency white noise appears.


Sign in / Sign up

Export Citation Format

Share Document