Research on Fault Diagnosis Monitoring System of Natural Gas Compressor

2014 ◽  
Vol 1048 ◽  
pp. 541-544
Author(s):  
Huan Huan Nie ◽  
Zhen Lu Wu ◽  
Guo Yan Yu

In this paper the structure of natural gas compressor monitoring system was designed. All the register data in PLC could be obtained to meet the real-time requirement by an instruction of PPI protocol. The technical framework of system was introduced simply, and the parameter method for measuring was put forward in fault diagnosis of natural gas compressor.

2014 ◽  
Vol 1003 ◽  
pp. 249-253
Author(s):  
Hao Fang ◽  
Ai Hua Li ◽  
Yan Fei Liu

To solve the difficulty of traditional video monitoring system in system upgrade and expansion, an solution of embedded video monitoring system based on DaVinci technology was put forward in this paper. By building the monitoring platform by DM6437 and DSP/BIOS in the solution, TVP5151 was used for receiving video signal in PAL/NTSC formats, and an JPEG Baseline Profile Encoder was integrated for video encoding, and the 10/100M Ethernet transmission function was realized based on NDK. Finally, the system is tested and the result shows that the system can capture and transmit D1 format signal in 25f/s and met the real-time requirement. At the same time, the system is easy to use and expand with a bright application prospect.


2021 ◽  
Author(s):  
Vadim Goryachikh ◽  
Fahad Alghamdi ◽  
Abdulrahman Takrouni

Abstract Background information Natural gas liquid (NGL) production facilities, typically, utilize turbo-expander-brake compressor (TE) to generate cold for C2+ separation from the natural gas by isentropic expansion of feed stream and use energy absorbed by expansion to compress residue gas. Experience shows that during operational phase TE can exposed to operation outside of design window that may lead to machine integrity loss and consequent impact on production. At the same time, there is a lack of performance indicators that help operator to monitor operating window of the machine and proactively identify performance deterioration. For instance, TE brake compressor side is always equipped with anti-surge protection system, including surge deviation alarms and trip. However, there is often gap in monitoring deviation from stonewall region. At the same time, in some of the designs (2×50% machines) likelihood of running brake compressor in stonewall is high during one machine trip or train start-up, turndown operating modes. Also, typical compressor performance monitoring systems does not have enough dynamic parameters that may indicate machine process process performance deterioration proactively (real-time calculation of actual polytrophic efficiency, absorbed power etc.) and help operator to take action before catastrophic failure occurs. In addition, typical compressor monitoring systems are based on assumed composition and fixed compressibility factor and do not reflect actual compositions variations that may affect machine performance monitoring. To overcome issues highlighted above, Hawiyah NGL (HNGL) team has developed computerized monitoring and advisory system to monitor the performance of turbo-expander-brake compressor, proactively, identify potentially unsafe conditions or performance deterioration and advice operators on taking necessary actions to avoid unscheduled deferment of production. Computerized performance monitoring system has been implemented in HNGL DCS (Yokogawa) and utilized by control room operators on day-to-day basis. Real-time calculation, analysis and outputs produced by performance monitoring system allow operator to understand how current operating condition are far from danger zone. Proactive deviation alarms and guide messages produce by the system in case of deviation help operators to control machine from entering unsafe region. Actual polytrophic efficiency, adsorbed power calculations provide machine condition status and allow identifying long-term performance deterioration trends.


2014 ◽  
Vol 530-531 ◽  
pp. 301-305
Author(s):  
Huan Huan Nie ◽  
Zhen Lu Wu ◽  
Guo Yan Yu

The frame structure of monitoring system is introduced and the network structure of monitoring system is analyzed in this paper. Fault diagnosis expert system is put forward and the fault inference rules are elaborated according to the fault of natural gas compressor of a company. The significance of the system is summarized in the end.


2013 ◽  
Vol 6 (4) ◽  
Author(s):  
Omar Ariosto Niño Prieto ◽  
Luis Enrique Colmenares-Guillén ◽  
Edilberto Huerta Niño ◽  
Aldo Enrique Aguila Jurado

2018 ◽  
Vol 2018 ◽  
pp. 1-12 ◽  
Author(s):  
Xianzhou Lyu ◽  
Weiming Wang

Shaft linings in thick weakly cemented stratum have the disadvantages of large deformation and repeated damage after repair. Considering the typical geologic characteristics and the failure characteristics of shaft linings, we establish a multilayer automatic deformation monitoring system in this paper, and the monitoring system can realize the real-time, continuous, and long-term dynamic monitoring on shaft linings. Based on the concrete strength failure criterion under biaxial compression and the analytical solution for spatially axisymmetric problem of thick-wall cylinders, the damage limit of the shaft lining in Xieqiao coal mine is obtained. Then, we choose three sections as the test area according to the typical damage forms of shaft linings to carry out the monitoring scheme on the auxiliary shaft in Xieqiao coal mine. The monitoring results show that the extreme value of the shaft lining deformation is 2.369 mm. And the shaft lining located in the border between the floor aquifer and the bedrock generates the most severe deformation, which is about 89.4% of the deformation limit. The shaft lining deformation increment fluctuates in certain range, which belongs to elastic deformation. Finally, we inverse the stress state according to the deformation value of the shaft lining, and the obtained additional stress is found to be lower than the ultimate compressive strength. Long-term project practice confirms that the deformation monitoring results can reflect the real stress condition of the shaft lining and that the monitoring system can realize the real-time dynamic evaluation for the status of the shaft lining.


2011 ◽  
Vol 121-126 ◽  
pp. 3750-3754 ◽  
Author(s):  
Chung Chiang Hu ◽  
Shing Han Li ◽  
Tien Wei Tsai

The equipments in computer rooms are complicated in nature. Many factors may influence their normal operations, for example: voltage, temperature, humidity, and the normalcy of systems. It would be prudent to have a monitoring system to prevent from unpredictable problems. Most monitoring systems in the market can only issue alarms in abnormal situations and then analyze the aftermath. They are also expansive and lack the ability for distant instant control. To tackle this problem, after our successful and practical experiments, we utilize GSM text messaging ability (i.e. SMS, short message service) and make distant monitoring possible. The monitoring system is established with a reasonable price that is well below current market. With this system, the manager/administrator can monitor the real-time status of equipments in computer rooms, send control commands through SMS and then get them executed to solve the problems instantly and effectively.