Experimental Study on the Mechanical Properties of Reinforced Concrete Columns after Exposure to Fire

2011 ◽  
Vol 243-249 ◽  
pp. 5122-5127
Author(s):  
Jia Feng Xu ◽  
Ming Zhe Liu ◽  
Yue Feng Tang

This paper provided three test data pertaining to the mechanical properties of reinforced concrete columns after exposure to ISO834 standard fire and three comparative test data pertaining to the mechanical properties of reinforced concrete columns at room temperature, mainly concerning the influence of fire on failure mode, distortion performance and ultimate load bearing capacity of reinforced concrete columns under axial and eccentric compression. Test results show that the failure mode of reinforced concrete columns after exposure to fire is basically same with that at room temperature. With the same concrete strength and heating condition, the bearing capacity of specimens reduces as the eccentricity increases. Strain along the section height of eccentric columns after fire basically agree with the plane section supposition while the flexural rigidity and ultimate load bearing capacity decreases obviously. The residual load bearing capacity of reinforced concrete columns after exposure to fire is only about 25% to 37% of that at room temperature.

2010 ◽  
Vol 163-167 ◽  
pp. 2240-2246 ◽  
Author(s):  
Jun Hua Li ◽  
Yue Feng Tang ◽  
Ming Zhe Liu

This paper provided three test data pertaining to the mechanical properties of steel reinforced concrete (SRC) eccentric columns after exposure to fire and one comparative test data pertaining to the mechanical properties of steel reinforced concrete columns at room temperature. The influence of eccentricity on failure mode, distortion performance and ultimate load bearing capacity are mainly studied. Test results show that the failure modes of steel reinforced concrete eccentric columns after exposure to fire are similar to that at room temperature. Strain along the section height at mid-span section of eccentric columns before loaded to 90% ultimate load bearing capacity is linearly distributed and well agree with the plane section supposition. After exposure to fire, the flexural rigidity and load bearing capacity of specimens are all declined compared with that at normal temperature. In various loading stages from the initial loading to 80% ultimate strength, the ratio of flexural rigidity of SRC eccentric columns after exposure to fire and at normal temperature is ranged from 0.30 to 0.59. With the same concrete strength and heating condition, the ultimate strength of specimens decreases with the increasing of eccentricity. The ultimate bearing capacity of all specimens at normal room temperature is calculated on the method proposed by Chinese regulation JGJ 138-2001. The compared results of experimental values and calculating values show that the residual load bearing capacity of SRC eccentric columns after exposure to fire is about 69% to 81% of that at room temperature.


2012 ◽  
Vol 193-194 ◽  
pp. 1429-1435
Author(s):  
Dong Liang Qiu ◽  
Kai Yu ◽  
Guo Feng Wang ◽  
Jun Hua Li

The mechanical properties of fire-damaged reinforced concrete columns rehabilitated by carbon fiber-reinforced polymer (CFRP) rods were studied. This study aims at the effectiveness of CFRP through the contrast test. Nine specimens were tested, including three normal temperature control specimens, and six specimens heated under ISO834 standard fire. After the specimens were exposed to fire, three of them were rehabilitated by CFRP. All specimens were loaded monotonically to failure in the same way. The results showed that the failure of reinforced concrete columns rehabilitated by CFRP was due to losing stabilization, whereas the others were material broken. Furthermore, because of the fire, the load-bearing capacity of specimens was all declined sharply compared with these at normal temperature. From this research, comparing with these normal temperature control specimens, the load-bearing capacity of specimens exposed to fire firstly was ranged from 0.25 to 0.37 times. But the ratio of the loading capacity of specimens rehabilitated by CFRP and normal temperature control ones was ranged from 0.54 to 0.67.


2012 ◽  
Vol 446-449 ◽  
pp. 311-317
Author(s):  
Ji Zhong Wang ◽  
Yong Feng Wang ◽  
Su Yan Wang

This paper compares three standards of FRP strengthened concrete columns published by ACI committee, Concrete Society and China respectively. A test is designed according to the comparison. A total of five columns were cast and tested. The analysis of the load bearing capacity and ductility of the test result indicates that wrapping hoop GFRP can enhance load bearing capacity slightly and the ductility greatly, wrapping axial GFRP can enhance load bearing capacity greatly but the failure of column is brittle, wrapping axial GFRP over-wrapped with hoop GFRP can both enhance load bearing capacity and the ductility.


Author(s):  
Klaus Holschemacher ◽  
Dennis Messerer ◽  
Wladislaw Polienko

The application of textile reinforced concrete is well-approved technique for strengthening of reinforced concrete members. When using carbon fiber meshes and carbon fiber reinforced polymer bars as reinforcement, this material is called carbon concrete composite. Based on the outstanding properties of carbon fibers, carbon concrete composite is characterized by high bending and tensile strength, and good durability. Therefore, carbon concrete composite is increasingly applied as replacement for ordinary steel bar or steel mesh reinforced concrete. It is favorable building material for production of new buildings and for strengthening of existing reinforced concrete members. In the context of strengthening of existing reinforced concrete columns, it is a usual procedure to cover the member’s surface with a thin layer of carbon concrete composite aiming on reduction of lateral strains of the core concrete when load is increasing. The result is an increased load-bearing capacity of the strengthened column. However, there is insufficient knowledge about the influence of curvature of the carbon meshes in circular cross-sections and in the corners of rectangular cross-sections on their load-bearing capacity. For this reason, an experimental program started to study the influence of curvature, number and type of mesh layers and specimen dimensions on structural behavior of strengthened columns under axial loading. As main outcome it can be stated that besides the curvature other parameters like yarn properties are of essential importance.


2021 ◽  
Vol 60 (1) ◽  
pp. 64-79
Author(s):  
Junqing Hong ◽  
Shaofeng Zhang ◽  
Hai Fang ◽  
Xunqian Xu ◽  
Honglei Xie ◽  
...  

Abstract The performance of textile reinforced concrete composite panels (TRCCPs) under the action of pseudo-static load up to collapse was evaluated. The test of TRCCPs under axial and transverse loading was conducted, and the results were compared with those for steel wire mesh reinforced-concrete composite panels (SMRCCPs). Ceram-site concrete was utilized as the panel matrix owing to its lightweight and insulation characteristics. The ultimate load bearing capacity, load-deformation and load-strain relationships, and failure modes were discussed and investigated in comparison with the findings of non-linear finite-element-model (FEM) analysis and the analytic method on the basis of the reinforced concrete (RC) theory. The analysis results indicate that TRCCP is suitable for use as a potential structural member for a wall or slab system of buildings, and the typical RC theory can be applied to predict the ultimate load bearing capacity if modified suitably.


2013 ◽  
Vol 815 ◽  
pp. 262-267
Author(s):  
Le Zhou ◽  
Xiao Chu Wang ◽  
Jian Peng Zhang

The mechanical properties of FRP steel-reinforced concrete columns are discussed. We study the constitutive relation of the concrete, based on the model and the experimental dates for the control the size of affecting parameters. When using the used model, the experimental dates can be reanalyzed and corrected for the intensity correct formula of FRP column. The ultimate bearing capacities of FRP constraint rectangular column use superposition principle to calculate the strength calculation. The ultimate bearing capacity of FRP column is divided into two parts: we conclude the big eccentric bearing capacity calculators formula by the columns bend. Through the study of the column, we concluded that the eccentric loading little eccentric calculation formula of bearing capacity. A case though using the example of this formula is similar with experiments results of the data.


2004 ◽  
Vol 88 (6) ◽  
pp. 461-466
Author(s):  
Hua Zhao ◽  
Xudong Shao ◽  
Guangdong Liu ◽  
Mingxian Cheng ◽  
Ping Zhu

Sign in / Sign up

Export Citation Format

Share Document