Study on Regeneration Ability of Oxidation Film on Ignition-Proof Magnesium Alloy Added with RE

2011 ◽  
Vol 284-286 ◽  
pp. 1665-1670
Author(s):  
Zheng Hua Deng ◽  
Hua Ji Li ◽  
Wei Bin Li

The ZM5-0.1%RE magnesium alloy was heated to 800°C, when the surface oxide film was formed, the ZM5-0.1% RE Magnesium alloy which had being oxidized obtained by removing the surface oxidation film on the ZM5-0.1%RE magnesium alloy at room temperature. TGA curve, oxidaxion kinetics curves at constant temperatuers of the alloy and XRD spectrum of the surface film were analyzed in order to investigate the sureface oxidation behavior.The results show that the alloy still has anti-oxidation performance, And the oxide inerease occurred mostly between 400°C and 700°C,a layer of tight oxide film with 4-5.5um and composed of RE2O3, MgO, Al2O3and Mg17Al12was formed on the surface of magnesiurn alloy. The tight surface oxide film prevented the further oxidation of the base magnesiurn alloy, It show that the regeneration ability of oxidation film on ZM5-0.1%RE Magnesium Alloy was good.

Author(s):  
T. Saito ◽  
T. Hanasaki ◽  
T. Moriwaki ◽  
T. Goto ◽  
A. Takeda ◽  
...  

2007 ◽  
Vol 539-543 ◽  
pp. 3649-3654 ◽  
Author(s):  
Kenzo Asaoka ◽  
Kunimitsu Maejima

Thermal desorption spectroscopy (TDS) was applied to measure the hydrogen in titanium (Ti). Because fracture by hydrogen embrittlement for medical/dental devices of Ti and Ti alloys was reported, dependence of surface oxidation film on hydrogen absorption and desorption behaviors of cp-Ti was carried out. To form the surface oxide film (rutile), the Ti wire samples were annealed in an ambient air at 800oC for 2 hours. Half of the specimens were immersed in a mixed solution of NaF and H3PO4 (APF). The part of the specimens were removed the surface films by abrasion after the heat and the immersion in the APF solution. TDS analysis was applied to detect released ions/molecules during heating from room temperature to 1200oC in a high vacuum vessel for the TiH2 powders, the Ti samples with and without the above treatments. High ion intensity was detected for hydrogen (m/z = 2), and ion intensities of the other ions/molecules were almost the background level in measurements. The concentration of hydrogen in the samples related with heat and chemical process was determined quantitatively, and was not significantly increased by the annealing and the immersion in APF solution if the sample had the tough surface film. However, the sample, which had been removed the surface films before the immersion in APF, showed typical chemical degradation after the immersion in APF for 7 days, that is, high ion intensities of hydrogen, fluoride, water and hydroxyl ions were detected. It was concluded that the control of the surface oxide film on the medical/dental Ti devices is important in determining its longevity.


2019 ◽  
Vol 166 (11) ◽  
pp. C3376-C3388 ◽  
Author(s):  
Zuocheng Wang ◽  
Francesco Di-Franco ◽  
Antoine Seyeux ◽  
Sandrine Zanna ◽  
Vincent Maurice ◽  
...  

2012 ◽  
Vol 258 (14) ◽  
pp. 5490-5498 ◽  
Author(s):  
Akiko Nagai ◽  
Yusuke Tsutsumi ◽  
Yuta Suzuki ◽  
Keiichi Katayama ◽  
Takao Hanawa ◽  
...  

1990 ◽  
Vol 31 ◽  
pp. 389-394 ◽  
Author(s):  
Haruo Tomari ◽  
Fumihiro Satoh ◽  
Makoto Terada ◽  
Hiroshi Satoh ◽  
Tadahiro Ohmi ◽  
...  

2005 ◽  
Vol 241 (3-4) ◽  
pp. 459-470 ◽  
Author(s):  
Petia Gencheva ◽  
Tzvety Tzvetkoff ◽  
Martin Bojinov

Sign in / Sign up

Export Citation Format

Share Document